Analysis of Neuron-Specific enolase isozymes in human serum using immunoaffinity purification and liquid chromatography-tandem mass spectrometry quantification

被引:6
|
作者
Genet, Sylvia A. A. M. [1 ,2 ,3 ,5 ]
Wolfs, Jur R. E. [1 ,2 ]
Vu, Chris B. A. K. [1 ,2 ]
Wolter, Madita [1 ,2 ]
Broeren, Maarten A. C. [4 ,5 ]
van Dongen, Joost [1 ,2 ,5 ]
Brunsveld, Luc [1 ,2 ,5 ]
Scharnhorst, Volkher [1 ,2 ,3 ,5 ]
Van de Kerkhof, Daan [1 ,2 ,3 ,6 ]
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Lab Chem Biol, Eindhoven, Netherlands
[2] Eindhoven Univ Technol, Inst Complex Mol Syst, Eindhoven, Netherlands
[3] Catharina Hosp, Eindhoven, Netherlands
[4] Maxima Med Ctr, Eindhoven Veldhoven, Netherlands
[5] Expert Ctr Clin Chem Eindhoven, Eindhoven, Netherlands
[6] Clin Lab Catharina Hosp Eindhoven, Michelangelolaan 2, NL-5623 EJ Eindhoven, Netherlands
关键词
Neuron -specific enolase (NSE); Reversible protein denaturation; Lung cancer; immunoaffinity (IA); Tryptic digestion; Liquid chromatography -tandem mass; spectrometry (LC -MS; MS); COLD DENATURATION; LC-MS/MS; PROTEIN; MARKER; IMMUNOCAPTURE; BIOMARKERS; THERAPY; ASSAY;
D O I
10.1016/j.jchromb.2023.123701
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Neuron-specific enolase (NSE) is a promising small-cell lung cancer (SCLC) biomarker composed of alpha gamma and gamma gamma isozyme dimers. As the conventional immunoassays are prone to interferences and cannot differentiate between the isozymes, we developed a multiplex immunoaffinity (IA) liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for the quantification of NSE alpha and NSE gamma in human serum. A calibrator was prepared by performing cold denaturation of recombinantly expressed alpha alpha and gamma gamma enolase dimers to induce a new dimer equilibrium that was determined to be approximately 1 alpha gamma:1 gamma gamma:1 alpha alpha. Selective sample purification was achieved by performing IA extraction using an antibody specific towards NSE gamma. The isolated alpha gamma and gamma gamma dimers were denatured and trypsin digested to allow quantification of the selected signature peptides and their corresponding isotopically labelled peptide internal standard. The obtained linear dynamic ranges were determined to be 1.5-56 ng/ mL and 0.64-167 ng/mL for NSE alpha and NSE gamma (R2 = 0.88 and 0.97 respectively). Validation of the assay showed acceptable accuracy and precision for NSE alpha and NSE gamma. The method was successfully applied to patient serum in which both isozymes were detected. Compared to the conventional immunoassay, substantially lower total NSE concentrations were measured in IA LC-MS/MS. With this multiplex IA LC-MS/MS assay, the clinical value of quantifying the individual isozymes can be explored. In addition, together with the calibrator described here, it may be applied to standardize NSE immunoassays across different platforms.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Rapid quantification of bile acids and their conjugates in serum by liquid chromatography-tandem mass spectrometry
    Scherer, Max
    Gnewuch, Carsten
    Schmitz, Gerd
    Liebisch, Gerhard
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (30): : 3920 - 3925
  • [42] Quantification of voriconazole in plasma by liquid chromatography-tandem mass spectrometry
    Vogeser, M
    Schiel, X
    Spöhrer, U
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2005, 43 (07) : 730 - 734
  • [43] Quantification of pregnanolone isomers and progesterone by liquid chromatography-tandem mass spectrometry in serum and brain
    Almeida, Felipe Borges
    da Silva, Izadora Amorim Garcia
    Eller, Sarah
    de Oliveira, Tiago Franco
    Pinna, Graziano
    Nin, Mauricio Schuler
    Barros, Helena Maria Tannhauser
    JOURNAL OF NEUROCHEMISTRY, 2023, 166 : 157 - 157
  • [44] Identification and quantification of tamoxifen and four metabolites in serum by liquid chromatography-tandem mass spectrometry
    Gjerde, J
    Kisanga, ER
    Hauglid, M
    Holm, PI
    Mellgren, G
    Lien, EA
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (01) : 6 - 14
  • [45] Quantification and validation of a liquid chromatography-tandem mass spectrometry assay for serum busulfan levels
    Ekremoglu, M.
    Kurdoglu, E. E.
    Oktem, M.
    FEBS JOURNAL, 2013, 280 : 279 - 279
  • [46] Quantification of fluoroquinolones in wastewaters by liquid chromatography-tandem mass spectrometry
    Maia, Alexandra S.
    Paiga, Paula
    Delerue-Matos, Cristina
    Castro, Paula M. L.
    Tiritan, Maria Elizabeth
    ENVIRONMENTAL POLLUTION, 2020, 259
  • [47] Quantification of urinary folate catabolites using liquid chromatography-tandem mass spectrometry
    Niesser, Mareile
    Harder, Ulrike
    Koletzko, Berthold
    Peissner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 929 : 116 - 124
  • [48] An immunoaffinity liquid chromatography-tandem mass spectrometry assay for the quantitation of matrix metalloproteinase 9 in mouse serum
    Ocana, Mireia Fernandez
    Neubert, Hendrik
    ANALYTICAL BIOCHEMISTRY, 2010, 399 (02) : 202 - 210
  • [49] Quantification and Validation of Ertapenem Using a Liquid Chromatography-Tandem Mass Spectrometry Method
    van Rijn, S. P.
    Wessels, A. M. A.
    Greijdanus, B.
    Touw, D. J.
    Alffenaar, J. W. C.
    ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2014, 58 (06) : 3481 - 3484
  • [50] Rapid quantification of the aminoglycoside arbekacin in serum using high performance liquid chromatography-tandem mass spectrometry
    Breaud, Autumn R.
    Henemyre-Harris, Claudia L.
    Schools, Sabitha
    Emezienna, Nkechinyere
    Clarke, William
    CLINICA CHIMICA ACTA, 2013, 418 : 102 - 106