Fast and accurate method for short-circuit current calculation in distribution network with IIDGs

被引:3
|
作者
Ye, Ruikai [1 ]
Wang, Huifang [1 ]
Bashir, Tasarruf [1 ]
Zhang, Yixiang [1 ]
机构
[1] Zhejiang Univ, Coll Elect Engn, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Short-circuit current calculation; Multi-output regression; Inverter interfaced distributed generator; Distribution network; Data-driven model; PROTECTION; SCHEME;
D O I
10.1016/j.ijepes.2023.109622
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The fault behavior of Inverter Interfaced Distributed Generators (IIDGs) diverges from that of synchronous generators. When a substantial number of IIDGs are integrated into the distribution network, the conventional short-circuit current calculation technique, grounded in a mechanical framework, struggles to simultaneously satisfy the demands for both rapid computation and precision. This study introduces an alternative approach reliant on data analysis, enabling swift and precise computation of short-circuit currents across the IIDG-infused distribution grid. The investigation delves into the efficacy of multi-output regression techniques and the selection of the foundational learning algorithm. Specifically, two strategies are advanced: Multi-Target Regressor Stacking and Regressor Chains, both utilizing the Light Gradient Boosting Machine as the base learner. The influence of varying sample sizes on the multi-output computational model's performance is assessed. To ascertain the real-world viability of the multi-output regression methodology, two distinct fault characteristics pertaining to data-driven short-circuit current calculation are scrutinized using existing distribution network measurement conditions. The study reveals that, given a known distribution network structure, the proposed method can compute network-wide short-circuit currents across diverse IIDG penetration levels and fault scenarios through a singular model, maintaining a balance between computation precision and speed. If the distribution network's structure undergoes minor modifications, the model demonstrates reasonable adaptability, yet a retraining of the short-circuit current calculation model is recommended to ensure sustained accuracy in the face of significant network changes.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Differential current integral based bipolar short-circuit protection method for DC distribution network with blocking converters
    Li, Botong
    Yang, Xinlu
    Li, Bin
    Wen, Weijie
    Chen, Xiaolong
    Su, Jiang
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2021, 192 (192)
  • [42] A method to fast recognize short-circuit fault based on curvature of line current waveform
    Yang, Shangjin
    Wu, Shouyuan
    Dai, Chaobo
    [J]. Dianwang Jishu/Power System Technology, 2013, 37 (02): : 551 - 556
  • [43] A New Model for Short-Circuit Current Calculation of Distribution Networks Integrated with Numerous Distributed Generations
    Sun, Yiwei
    Liu, Bin
    Yue, Qing
    Wang, Yuchen
    Wang, Zhiwen
    Chen, Laijun
    [J]. 2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [44] The Contribution to Distribution Network Short-Circuit Current Level from the Connection of Distributed Generation
    Bojevic, Sreto
    Conlon, Michael F.
    [J]. 2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 640 - +
  • [45] Short-Circuit Calculation in Distribution Networks with Distributed Induction Generators
    Zhou, Niancheng
    Ye, Fan
    Wang, Qianggang
    Lou, Xiaoxuan
    Zhang, Yuxiang
    [J]. ENERGIES, 2016, 9 (04):
  • [46] Fast Prediction Method of Short-circuit Current Zero Based on an Algorithm of Long Short Term Memory
    Huang L.
    Zhang L.
    Hu Y.
    Yang H.
    Xiang B.
    Yao X.
    [J]. Gaodianya Jishu/High Voltage Engineering, 2023, 49 (12): : 5022 - 5031
  • [47] Simulation analysis on influences of distributed photovoltaic generation on short-circuit current in distribution network
    Liu, Jian
    Lin, Tao
    Tong, Xiangqian
    Li, Long
    Zhang, Zhihua
    [J]. Dianwang Jishu/Power System Technology, 2013, 37 (08): : 2080 - 2085
  • [48] An improved short circuit calculation method for distribution network with distributed generations
    Wang, Chengshan
    Sun, Xiaoqian
    [J]. Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2012, 36 (23): : 54 - 58
  • [49] Mechanism and data-driven combined short circuit current calculation method for distribution network with IIDG
    Zheng X.
    Wang H.
    Jiang K.
    Cao J.
    Liu Y.
    Chen Y.
    [J]. Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (01): : 41 - 47
  • [50] A Study on Short-circuit Capacity Calculation Method of Low-voltage Direct Current System Considering Short-circuit Characteristics of DC/DC Converter
    Oh C.-H.
    Lee K.-Y.
    Chae D.-J.
    Lim S.-T.
    [J]. Transactions of the Korean Institute of Electrical Engineers, 2023, 72 (11): : 1491 - 1497