Closed-loop control of anesthetic state in nonhuman primates

被引:1
|
作者
Chakravarty, Sourish [1 ,2 ]
Donoghue, Jacob [1 ,3 ,4 ]
Waite, Ayan S. [1 ,2 ]
Mahnke, Meredith [1 ]
Garwood, Indie C. [1 ,3 ,4 ]
Gallo, Sebastian [1 ]
Miller, Earl K. [1 ,4 ]
Brown, Emery N. [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] MIT, Picower Inst Learning & Memory, Cambridge, MA 02139 USA
[2] Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[3] MIT, Harvard MIT Div Hlth Sci & Technol, Cambridge, MA 02139 USA
[4] MIT, Dept Brain & Cognit Sci, Cambridge, MA 02139 USA
[5] MIT, Inst Med Engn & Sci, Cambridge, MA 02139 USA
[6] Harvard Med Sch, Dept Anaesthesia, Boston, MA 02115 USA
来源
PNAS NEXUS | 2023年 / 2卷 / 10期
关键词
closed-loop anesthesia delivery system; nonhuman primate; propofol; POSTOPERATIVE COGNITIVE DYSFUNCTION; BISPECTRAL INDEX; 2-DEGREE-OF-FREEDOM DESIGN; PERFORMANCE DETERIORATION; PREDICTIVE PERFORMANCE; PROPOFOL ANESTHESIA; SERVO SYSTEMS; DELIRIUM; ELECTROENCEPHALOGRAM; CONSCIOUSNESS;
D O I
10.1093/pnasnexus/pgad293
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Research in human volunteers and surgical patients has shown that unconsciousness under general anesthesia can be reliably tracked using real-time electroencephalogram processing. Hence, a closed-loop anesthesia delivery (CLAD) system that maintains precisely specified levels of unconsciousness is feasible and would greatly aid intraoperative patient management. The US Federal Drug Administration has approved no CLAD system for human use due partly to a lack of testing in appropriate animal models. To address this key roadblock, we implement a nonhuman primate (NHP) CLAD system that controls the level of unconsciousness using the anesthetic propofol. The key system components are a local field potential (LFP) recording system; propofol pharmacokinetics and pharmacodynamic models; the control variable (LFP power between 20 and 30 Hz), a programmable infusion system and a linear quadratic integral controller. Our CLAD system accurately controlled the level of unconsciousness along two different 125-min dynamic target trajectories for 18 h and 45 min in nine experiments in two NHPs. System performance measures were comparable or superior to those in previous CLAD reports. We demonstrate that an NHP CLAD system can reliably and accurately control in real-time unconsciousness maintained by anesthesia. Our findings establish critical steps for CLAD systems' design and testing prior to human testing.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] CLOSED-LOOP CONTROL OF URBAN TRAFFIC
    RHEE, SY
    YARDENI, A
    OPERATIONS RESEARCH, 1961, 9 : B29 - B30
  • [32] CLOSED-LOOP CONTROL OF A BALLISTIC RESPONSE
    WILLIAMS, ID
    ROY, EA
    JOURNAL OF MOTOR BEHAVIOR, 1972, 4 (02) : 121 - 126
  • [33] EFFICACY OF OUTPATIENT CLOSED-LOOP CONTROL
    Kovatchev, B.
    Renard, E.
    Cobelli, C.
    Zisser, H.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A12 - A13
  • [34] Identification and control - Closed-loop issues
    VandenHof, PMJ
    Schrama, RJP
    AUTOMATICA, 1995, 31 (12) : 1751 - 1770
  • [35] Introducing closed-loop nitrogen control
    Heller, David
    Circuits Assembly, 1997, 8 (11):
  • [36] Learning of Closed-Loop Motion Control
    Farshidian, Farbod
    Neunert, Michael
    Buchli, Jonas
    2014 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2014), 2014, : 1441 - 1446
  • [37] CLOSED-LOOP
    WINTERFLOOD, AH
    ELECTRONICS & WIRELESS WORLD, 1984, 90 (1577): : 51 - 51
  • [38] CLOSED-LOOP
    LEATHER, M
    INDUSTRIAL DISTRIBUTION, 1977, 67 (05): : 294 - 294
  • [39] Regulatory challenges facing closed-loop anesthetic drug infusion devices
    Manberg, P. J.
    Vozella, C. M.
    Kelley, S. D.
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2008, 84 (01) : 166 - 169
  • [40] Closed-Loop Magnetization State Control for a Variable-Flux Memory Machine
    Hu, Yusheng
    Chen, Junhua
    Qu, Ronghai
    Chen, Bin
    Xiao, Yong
    Li, Xia
    IEEE ACCESS, 2020, 8 : 146983 - 146993