Retrofit building energy performance evaluation using an energy signature-based symbolic hierarchical clustering method

被引:13
|
作者
Choi, Sebin [1 ]
Lim, Hyunwoo [2 ]
Lim, Jongyeon [3 ,4 ]
Yoon, Sungmin [1 ,5 ]
机构
[1] Sungkyunkwan Univ, Dept Global Smart City, Suwon 16419, South Korea
[2] Konkuk Univ, Dept Architecture, Seoul, South Korea
[3] Kangwon Natl Univ, Dept Architectural Engn, Chuncheon Si, Kangwon Do, South Korea
[4] Kangwon Natl Univ, Dept Integrated Energy & Infra Syst, Chuncheon Si, Gangwon Do, South Korea
[5] Sungkyunkwan Univ, Sch Civil Architectural Engn & Landscape Architect, Suwon 16419, South Korea
关键词
Retrofit; Top -down approach; Building energy performance; Energy signature; Symbolic hierarchical clustering; Open data; CONSUMPTION;
D O I
10.1016/j.buildenv.2024.111206
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Retrofitting existing buildings is crucial for significantly reducing energy consumption in the building sector. The continuous monitoring and evaluation of retrofit building energy efficiency is necessary to maintain optimal energy performance. This study proposes a novel method for evaluating building energy performance that combines energy signature analysis and hierarchical clustering. Symbolic data were defined by k-means using differences in gradients and y-intercepts before and after retrofitting extracted from energy signatures. Hierarchical clustering was then performed using the symbolic datasets. This symbolic hierarchical clustering method enhances the utility of open data and facilitates rapid decision-making. Additionally, it allows for a simple assessment of energy performance at the city scale. Through implementing this approach in 49 retrofitted buildings in Gangwon-do, South Korea, five types of symbolic data were identified (Types 0-4). Using hierarchical clustering, these buildings were clustered into six groups (Clusters 1-6). Type 3, representing ideal retrofitting outcomes, was observed in Clusters 2, 3, and 4 (73.47 % of all buildings). Conversely, Type 4 symbols, indicating a rebound effect, were observed in Cluster 1 and 2 (6.12 %). These findings provide meaningful information after retrofitting at the regional level, contributing to effective building management during retrofitting.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Performance evaluation of signature-based access mechanisms for efficient information retrieval
    Yoo, Jae Soo
    Chang, Jae Woo
    Lee, Yoon Joon
    Kim, Myoung Ho
    IEICE Transactions on Information and Systems, 1993, E76-D (02): : 179 - 188
  • [22] Load forecasting using hierarchical clustering method for building
    Hwang, Hye-Mi
    Lee, Sung-Hee
    Park, Jong-Bae
    Park, Yong-Gi
    Son, Sung-Yong
    Transactions of the Korean Institute of Electrical Engineers, 2015, 64 (01): : 41 - 47
  • [23] Measurement and verification analysis on the energy performance of a retrofit residential building after energy efficiency measures using RETScreen Expert
    Owolabi, Abdulhameed Babatunde
    Nsafon, Benyoh Emmanuel Kigha
    Roh, Jong Wook
    Suh, Dongjun
    Huh, Jeung-Soo
    ALEXANDRIA ENGINEERING JOURNAL, 2020, 59 (06) : 4643 - 4657
  • [24] PERFORMANCE AND ENERGY BASED DESIGN METHOD FOR THE BUILDING STRUCTURES WITH THE ENERGY DISSIPATION BRACINGS
    Xian, Qiao-Ling
    Gao, Yin
    Zhou, Fu-Lin
    Tan, Ping
    PROCEEDINGS OF THE ELEVENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING, VOL I AND II, 2010, : 817 - 822
  • [25] BUILDING PERFORMANCE ANALYSIS OF CHILDCARE CENTERS IN KOREA FOR RETROFIT DESIGN: TYPOLOGY BASED STUDY ON ENERGY PERFORMANCE
    Yoon, Yeon Joon
    Choi, Yerin
    Cheon, Sukyeong
    Lee, SangYun
    JOURNAL OF GREEN BUILDING, 2024, 19 (03): : 245 - 273
  • [26] Scalable Performance Analysis of ExaScale MPI Programs through Signature-Based Clustering Algorithms
    Bahmani, Amir
    Mueller, Frank
    PROCEEDINGS OF THE 28TH ACM INTERNATIONAL CONFERENCE ON SUPERCOMPUTING, (ICS'14), 2014, : 155 - 164
  • [27] An optimization model for building envelope retrofit considering energy performance certificate
    Fan, Yuling
    Xia, Xiaohua
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 2750 - 2755
  • [28] A study on building performance analysis for energy retrofit of existing industrial facilities
    Gourlis, Georgios
    Kovacic, Iva
    APPLIED ENERGY, 2016, 184 : 1389 - 1399
  • [29] An adjusted energy-saving quantity calculation method for building energy-efficient retrofit
    Wang Qing-qin
    Meng Chong
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2009, 16 : 265 - 269
  • [30] Evaluation of large scale building energy efficiency retrofit program in Kuwait
    Krarti, Moncef
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 50 : 1069 - 1080