Coupling simulation of the cooling air duct and the battery pack in battery energy storage systems

被引:6
|
作者
Zhu, Xinlong [1 ]
Xu, Xintian [1 ]
Kong, Benben [1 ]
Wang, Junyi [2 ]
Shi, Hong [2 ]
Jiang, Yanlong [1 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Key Lab Aircraft Environm Control & Life Support, MIIT, 29 Yudao St, Nanjing 210016, Peoples R China
[2] Jiangsu Univ Sci & Technol, Coll Energy & Power Engn, 666 Changhui Rd, Zhenjiang 212100, Peoples R China
关键词
battery energy storage system; cooling air ducts; uniform air supply; battery thermal management; LITHIUM-ION BATTERY; THERMAL MANAGEMENT-SYSTEM; ELECTRIC VEHICLES; PERFORMANCE; MECHANISMS; HYBRID; DEGRADATION; STRATEGIES;
D O I
10.1088/1402-4896/acd824
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The air-cooled battery thermal management system (BTMS) is a safe and cost-effective system to control the operating temperature of the battery energy storage system (BESS) within a desirable range. Different from the design of the air supply flow field of most BESSs in previous studies, this study proposes a novel calculation method that combines the cooling air duct and the battery pack to enhance the heat dissipation of the battery. Using computational fluid dynamics (CFD) models, potential problems with numerical calculations of cooling air duct and battery packs alone and coupled simulations of the two are investigated. The important factors influencing the uniformity of air supply are identified, and creative measures for improvement are proposed. The results in this paper show that the uniformity of the outlet air supply does not indicate that the temperature uniformity performance of the matrix battery meets the requirements due to the variation of the sub air duct outlet pressure, and the coupling simulation of the cooling air duct and the battery pack is an essential process for BESS. With the improvements proposed in this paper, the standard deviation coefficient of velocity is reduced from 60.3% to 12.6%. Furthermore, the innovative improvement of placing the partition in the connecting duct can regulates the battery temperature between 298.58 K and 311.73 K and ensures a maximum temperature difference of only 4.22 K for a single battery. Ultimately, the power consumption of the cooling system can be reduced by 6.9%. The results of the paper provide a guide for uniform heat dissipation in BESS.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] Thermal simulation analysis and optimization of forced air cooling system for energy storage lithium-ion battery pack
    Lü C.
    Zhang S.
    Zhu S.
    Song Y.
    Ge Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2021, 49 (12): : 48 - 55
  • [2] The forced air cooling heat dissipation performance of different battery pack bottom duct
    Xu Xiaoming
    Tang Wei
    Fu Jiaqi
    Hu Donghai
    Sun Xudong
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (12) : 3823 - 3836
  • [3] Simulation and analysis of air cooling configurations for a lithium-ion battery pack
    Li, Xinke
    Zhao, Jiapei
    Yuan, Jinliang
    Duan, Jiabin
    Liang, Chaoyu
    JOURNAL OF ENERGY STORAGE, 2021, 35
  • [4] A study of different battery thermal management systems for battery pack cooling in electric vehicles
    Wankhede, Sagar
    Thorat, Prajwal
    Shisode, Sanket
    Sonawane, Swapnil
    Wankhade, Rugved
    HEAT TRANSFER, 2022, 51 (08) : 7487 - 7539
  • [5] An improved air supply scheme for battery energy storage systems
    Zhu XINLONG
    Shi HONG
    Xu WENBING
    Zhang TONG
    Wang YANSONG
    BULLETIN OF THE POLISH ACADEMY OF SCIENCES-TECHNICAL SCIENCES, 2022, 70 (02)
  • [6] Flow study on lithium-ion battery pack with air cooling
    Seongjong Park
    Jong Keun Yu
    Heesung Lee
    Ho Kyung Choi
    Journal of Mechanical Science and Technology, 2023, 37 : 4631 - 4638
  • [7] Flow study on lithium-ion battery pack with air cooling
    Park, Seongjong
    Yu, Jong Keun
    Lee, Heesung
    Choi, Ho Kyung
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2023, 37 (09) : 4631 - 4638
  • [8] Experimental and numerical studies on air cooling and temperature uniformity in a battery pack
    Shahid, Seham
    Agelin-Chaab, Martin
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (06) : 2246 - 2262
  • [9] Influence of uncertainties in a battery pack with air cooling for electric vehicles on temperature difference and volume of battery module
    Sharma, Anshu
    Shukla, Neeraj Kumar
    Garg, Aman
    Alammar, Mohammed M.
    Raman, Roshan
    Mukherjee, Debasis
    Li, Li
    JOURNAL OF ENERGY STORAGE, 2025, 113
  • [10] Comparative Study of Air Cooling and Immersion Cooling for the Thermal Management of a Cylindrical Battery Pack
    Kim, Jin Sub
    Kim, Seul Ah
    Shin, Dong Hwan
    Kim, Wookyoung
    Moon, Sunyoung
    Chung, Yoong
    Sohn, Sangho
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, 2023, 47 (10) : 543 - 550