Thermal performance of an advanced smart fenestration systems for low-energy buildings

被引:1
|
作者
Ming, Yang [1 ]
Sun, Yanyi [1 ,2 ]
Liu, Xin [1 ]
Liu, Xiao [1 ]
Wu, Yupeng [1 ]
机构
[1] Univ Nottingham, Fac Engn, Nottingham NG7 2RD, England
[2] Kingston Univ, Fac Engn Comp & Environm, Sch Built Environm & Geog, Dept Civil Engn Surveying & Construct Management, Kingston, England
基金
英国工程与自然科学研究理事会;
关键词
Adaptive facade; Thermotropic material; Transparent insulation materials; Solar energy; Thermal performance; INSULATION MATERIALS; SOLAR; WINDOW;
D O I
10.1016/j.applthermaleng.2024.122610
中图分类号
O414.1 [热力学];
学科分类号
摘要
Windows significantly influence a building's indoor environment and energy consumption due to their high optical transmittance and low thermal resistance comparing with walls, affecting both indoor daylight comfort and heat gain or loss. Thermotropic (TT) materials can offer dynamic regulation of solar energy, improving building energy efficiency. Parallel slats transparent insulation materials (PS -TIM) integrated into the air cavity of double -glazing windows can effectively increase the thermal resistance of a window. In this study, these two advanced technologies were combined to develop a new type of adaptive fenestration system, named Thermotropic Parallel Slat Transparent Insulation Material (TT PS -TIM) system. The selected TT hydrogel, 5 wt% poly(Nisopropyl acrylamide) (PNIPAm), was sandwiched within polymethyl methacrylate (PMMA) slices. The slats were subsequently proposed between two glass panes to form a parallel slat transparent insulation materials system. To investigate the thermal and optical properties of the TT slats as well as the thermal performance (i.e., solar heat gain coefficient, and dynamic thermal performance in summer and winter) of the TT PS -TIM system with different slats intervals, a novel model combining Ray -tracing technique and Computational Fluid Dynamics (CFD) has been proposed. The findings of this study reveal that a TT PS -TIM system incorporating 5 wt% PNIPAm slats can offer a substantial reduction (up to 0.5) in solar transmittance as it transitions from a clear to a translucent state. Accompanied with the phase transition of the TT slats, there is a significant reduction in the Solar Heat Gain Coefficient (SHGC) of the window system. This effectively decreases the unwanted solar heat gain, thus improving the overall buildings thermal performance. According to the advanced transient simulation results based on the weather conditions of London, the TT PS -TIM system exhibits superior performance evidenced by over a 30% reduction in heat gain during summer and approximately a 20% reduction in heat loss during winter in contrast to a conventional Double Glazing (DG) system. This is evident in the form of reduced heat gain during summer and minimized heat loss during winter, resulting in a more thermally balanced environment throughout the year. The comprehensive thermal investigation of TT PS -TIM can effectively help to increase the accuracy of the further energy and daylight analysis.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Engaging schools in the science of low-energy buildings
    Charnley, Fiona
    Fleming, Paul
    Dowsett, Tony
    Fleming, Margaret
    Cook, Malcolm
    Mill, Greig
    [J]. PUBLIC UNDERSTANDING OF SCIENCE, 2012, 21 (07) : 875 - 890
  • [32] ON THE LIMITS OF THE QUASI-STEADY-STATE METHOD TO PREDICT THE ENERGY PERFORMANCE OF LOW-ENERGY BUILDINGS
    Ballarini, Ilaria
    Primo, Elisa
    Corrado, Vincenzo
    [J]. THERMAL SCIENCE, 2018, 22 : S1117 - S1127
  • [33] Low-energy buildings heat supply-Modelling of energy systems and carbon emissions impacts
    Sandvall, Akram Fakhri
    Ahlgren, Erik O.
    Ekvall, Tomas
    [J]. ENERGY POLICY, 2017, 111 : 371 - 382
  • [34] Uncertainty and parameter ranking analysis on summer thermal characteristics of the hydronic thermal barrier for low-energy buildings
    Chen, Sarula
    Yang, Yang
    Chang, Tianxin
    [J]. BUILDING SIMULATION, 2023, 16 (01) : 27 - 49
  • [35] Uncertainty and parameter ranking analysis on summer thermal characteristics of the hydronic thermal barrier for low-energy buildings
    Sarula Chen
    Yang Yang
    Tianxin Chang
    [J]. Building Simulation, 2023, 16 : 27 - 49
  • [36] Peripheral Isothermal System of Heat Gain Storage for Thermal Stability in Low-Energy Buildings
    Weglarz, Arkadiusz
    Pierzchalski, Michal
    Heim, Dariusz
    [J]. APPLIED SCIENCES-BASEL, 2019, 9 (15):
  • [37] Comparison of low-energy office buildings in summer using different thermal comfort criteria
    Pfafferott, Jens U.
    Herkel, Sebastian
    Kalz, Doreen E.
    Zeuschner, Andreas
    [J]. ENERGY AND BUILDINGS, 2007, 39 (07) : 750 - 757
  • [38] The seismic response of low-energy buildings founded on a thermal insulation layer - A parametric study
    Azinovic, Boris
    Koren, David
    Kilar, Vojko
    [J]. ENGINEERING STRUCTURES, 2014, 81 : 398 - 411
  • [39] Assessing energy and thermal comfort of different low-energy cooling concepts for non-residential buildings
    Salvalai, Graziano
    Pfafferott, Jens
    Sesana, Marta Maria
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2013, 76 : 332 - 341
  • [40] Advanced Energy Efficiency Systems in Buildings
    Borge-Diez, David
    [J]. ENERGIES, 2022, 15 (19)