A Novel Plating System for First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Hybrid and Traditional Locking Plate Constructs

被引:1
|
作者
Elattar, Osama [1 ]
Andrews, Nicholas A. [2 ]
Halstrom, Jared [2 ]
Harrelson, Whitt M. [2 ]
Nair, Pallavi [2 ]
Shah, Ashish [2 ,3 ]
机构
[1] Univ Toledo, Dept Orthopaed Surg, Toledo, OH USA
[2] Univ Alabama Birmingham, Dept Orthopaed Surg, Birmingham, AL USA
[3] Univ Alabama Birmingham, Dept Orthopaed Surg, Clin Res, 1313 13th St South, Birmingham, AL 35205 USA
关键词
hallux rigidus; first metatarsophalangeal joint; arthrodesis; locking plate; NITINOL COMPRESSION STAPLES; DOME-SHAPED REAMERS; CROSSED-SCREWS; DORSAL PLATE; FIXATION; UNION; PATHOLOGY;
D O I
10.1177/19386400211067860
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundDorsal plate fixation is commonly used for first metatarsophalangeal joint (1st MTPJ) arthrodesis and plate design continues to evolve. A new staple compression plate (SCP) design attempts to utilize the continuous compression of a nitinol staple across the fusion site while simultaneously providing the stability of a dorsal locked plate. Herein, we compare the radiographic, clinical, and patient-reported outcomes of 1st MTPJ joint arthrodesis using 2 dorsal locking plate constructs including a novel SCP construct.MethodsForty-four patients who underwent 1st MTPJ arthrodesis between 2016 and 2020 were retrospectively evaluated. There were 2 group cohorts. Group 1 cohort included 23 patients who received a CrossRoads Extremity SCP, and Group 2 cohort included 21 patients who received a Stryker dorsal locking precontoured titanium plate (LPP). All patients were evaluated with radiographs, Patient-Reported Outcomes Measures Information System (PROMIS) outcome scores, and Foot Function Index (FFI).ResultsThe complication and union rates did not vary between groups with a fusion rate of 95.7% in the SCP group and 90.5 % in the LPP group. Similarly, we found no significant differences in PROMIS or FFI scores between the SCP and LPP plates.ConclusionUse of either dorsal locking plate construct for 1st MTPJ arthrodesis was associated with high union rates and comparable functional outcomes. As locked plate technology continues to evolve for 1st MTPJ arthrodesis, it is important that clinical outcomes are reported.Levels of Evidence:Level IV
引用
收藏
页码:537 / 546
页数:10
相关论文
共 50 条
  • [21] Incidence of Nonunion Following First Metatarsophalangeal Joint Arthrodesis for Hallux Valgus Deformity: A Retrospective Analysis of Four Different Constructs
    Reardon, Brennan K.
    Leffler, Luke E.
    Hoffler, Hayden L.
    Evans, Joni K.
    Blazek, Cody D.
    Scott, Aaron T.
    Dial, Dekarlos M.
    JOURNAL OF FOOT & ANKLE SURGERY, 2023, 62 (03): : 536 - 542
  • [22] Immediate Weightbearing After First Metatarsophalangeal Joint Arthrodesis With Screw and Locking Plate Fixation: A Short-Term Review
    Abben, Kyle W.
    Sorensen, Matthew D.
    Waverly, Brett J.
    JOURNAL OF FOOT & ANKLE SURGERY, 2018, 57 (04): : 771 - 775
  • [23] Comparison of limited-contact dynamic compression plate and locking compression plate constructs for proximal interphalangeal joint arthrodesis in the horse
    Rocconi, Richard A.
    Carmalt, James L.
    Sampson, Sarah N.
    Elder, Steve H.
    Gilbert, Eric E.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2015, 56 (06): : 615 - 619
  • [24] Effect of lag screw on stability of first metatarsophalangeal joint arthrodesis with medial plate
    Daszkiewicz, Karol
    Rucka, Magdalena
    Czuraj, Krzysztof
    Andrzejewska, Angela
    Luczkiewicz, Piotr
    PEERJ, 2024, 12
  • [25] Biomechanical comparison of two fixation methods for first metatarsophalangeal joint arthrodesis
    Molloy, S
    Burkhart, BG
    Jasper, LE
    Solan, MC
    Campbell, JT
    Belkoff, SM
    FOOT & ANKLE INTERNATIONAL, 2003, 24 (02) : 169 - 171
  • [26] Cost Comparison of Synthetic Hydrogel Implant and First Metatarsophalangeal Joint Arthrodesis
    Rothermel, Shane D.
    King, Jesse L.
    Tupinio, Maegan
    Walley, Kempland C.
    Juliano, Paul J.
    Aynardi, Michael C.
    FOOT & ANKLE SPECIALIST, 2020, 13 (04) : 281 - 285
  • [27] Evaluating the Biomechanical Integrity of Various Constructs Utilized for First Metatarsophalangeal Joint Arthrodesis: A Systematic Review
    Balu, Abhinav R.
    Baumann, Anthony N.
    Tsang, Terence
    Talaski, Grayson M.
    Anastasio, Albert T.
    Walley, Kempland C.
    Adams, Samuel B.
    MATERIALS, 2023, 16 (19)
  • [28] Different fixation constructs and the risk of non-union following first metatarsophalangeal joint arthrodesis
    Cichero, Matthew J.
    Yates, Ben J.
    Joyce, Anthony S. D.
    Williamson, David M.
    Walsh, Tom P.
    FOOT AND ANKLE SURGERY, 2021, 27 (07) : 789 - 792
  • [29] Retrospective Comparison of Titanium Hybrid Locking Plate with Stainless Steel Hybrid Dynamic Compression Plate for Pancarpal Arthrodesis: 23 dogs
    Chong, Wye Li
    Eckart, Louisa Ho
    Sul, Rui
    Jermyn, Kieri
    Michelsen, Jacob
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2022, 35 (04) : 270 - 277
  • [30] Midfoot Arthrodesis Following Multi-Joint Stabilization With a Novel Hybrid Plating System
    Filippi, Jorge
    Myerson, Mark S.
    Scioli, Mark W.
    Den Hartog, Bryan Dale
    Kay, David B.
    Bennett, Gordon L.
    Stephenson, Kenneth A.
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (03) : 220 - 225