A two-step method for kinematic parameters calibration based on complete pose measurement-Verification on a heavy-duty robot

被引:9
|
作者
Miao, Lei [1 ,2 ]
Zhang, Yongliang [1 ,2 ,3 ]
Song, Zhichao [1 ,2 ,3 ]
Guo, Yingjie [1 ,2 ]
Zhu, Weidong [1 ,2 ]
Ke, Yinglin [1 ,2 ]
机构
[1] Zhejiang Univ, Sch Mech Engn, State Key Lab Fluid Power & Mechatron Syst, Hangzhou 310027, Peoples R China
[2] Zhejiang Univ, Sch Mech Engn, Key Lab Adv Mfg Technol Zhejiang Prov, Hangzhou 310027, Peoples R China
[3] AV Shenyang Aircraft Corp, Shenyang 110850, Peoples R China
基金
中国国家自然科学基金;
关键词
Kinematic calibration; Redundant parameters analysis; Heavy-duty robot; Complete pose measurement; Two-step calibration; INDUSTRIAL ROBOT; ERROR COMPENSATION; MODEL; IDENTIFICATION; SYSTEM;
D O I
10.1016/j.rcim.2023.102550
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The poor pose accuracy of industrial robots restricts their further application in aviation manufacturing. Kinematic calibration based on position errors is a traditional method to improve robot accuracy. However, due to the difference between length errors and angle errors in the order of magnitude, it is difficult to accurately calibrate these geometric parameters together. In this paper, a two-step method for robot kinematic parameters calibration and a novel method for position and orientation measurement are proposed and combined to identify these two kinds of errors respectively. The redundant parameter errors that affect the identification are also analyzed and eliminated to further improve the accuracy of this two-step method. Taking the Levenberg-Marquardt algorithm as the underlying algorithm, simulation results indicate that the proposed two-step calibration method has faster iteration speed and higher identification accuracy than the traditional one. On this basis, the calibration and measurement methods proposed in this paper are verified on a heavy-duty robot used for fiber placement. Experimental results show that the mean absolute position error decreases from 0.9906 mm to 0.3703 mm after calibration by the proposed two-step calibration method with redundancy elimination. The absolute position accuracy has increased by 41.81% compared with the traditional method based on position errors only and 14.97% compared with the two-step calibration method without redundancy elimination. At the same time, the orientation errors after calibration are not more than 0.1485 degrees, and the average of absolute errors is 0.0447.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] A two-step calibration method of lenslet-based light field cameras
    Zhou, Ping
    Cai, Weijia
    Yu, Yunlei
    Zhang, Yuting
    Zhou, Guangquan
    OPTICS AND LASERS IN ENGINEERING, 2019, 115 : 190 - 196
  • [22] Image-based modeling using a two-step camera calibration method
    Carvalho, PCP
    Szenberg, F
    Gattass, M
    SIBGRAPI '98 - INTERNATIONAL SYMPOSIUM ON COMPUTER GRAPHICS, IMAGE PROCESSING, AND VISION, PROCEEDINGS, 1998, : 388 - 395
  • [23] A simple and rapid calibration methodology for industrial robot based on geometric constraint and two-step error
    Zhang, Jiabo
    Wang, Xibin
    Wen, Ke
    Zhou, Yinghao
    Yue, Yi
    Yang, Jizhi
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2018, 45 (06): : 715 - 721
  • [24] Kinematic Parameters Calibration Method of Serial Robot Based on ZRM-MDH Model Transformation
    Qiao G.
    Wan Q.
    Lü Z.
    Kang C.
    Sun D.
    Wen X.
    Nongye Jixie Xuebao/Transactions of the Chinese Society for Agricultural Machinery, 2021, 52 (03): : 382 - 389
  • [25] Plane kinematic calibration method for industrial robot based on dynamic measurement of double ball bar
    Yang, Ping
    Guo, Zhiguang
    Kong, Yangbo
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2020, 62 : 265 - 272
  • [26] A step-step calibration method based on two-eye stereo vision measuring robot
    Li Zhanfeng
    Zhang Jianping
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL I, 2007, : 50 - 54
  • [27] Calibration Method and Simulation of Kinematic Parameters for Light-Weight Robot Based on Flexible Error Analysis
    Chen, Gang
    Wang, Lei
    Jia, Qingxuan
    Wang, Shiwei
    2017 2ND INTERNATIONAL CONFERENCE ON CYBERNETICS, ROBOTICS AND CONTROL (CRC 2017), 2017, : 23 - 27
  • [28] A Novel Calibration Method for Robot Kinematic Parameters Based on Improved Manta Ray Foraging Optimization Algorithm
    Xu, Xiaobin
    Bai, Yonghua
    Zhao, Minghui
    Yang, Jian
    Pang, Fenglin
    Ran, Yingying
    Tan, Zhiying
    Luo, Minzhou
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [29] Geometric Calibration Method of Robot Based on Measurement System Including Position and Orientation Parameters
    Deli Zhang
    Yu Zhu
    Lu Yang
    Zhe Liu
    Journal of Harbin Institute of Technology(New series), 2023, 30 (06) : 1 - 11
  • [30] Measurement Method of Void Fraction in Narrow Channel Based on Two-step Morphological Image Method
    Pan L.
    Liu Y.
    Li W.
    Liu Y.
    Liu, Yang (liu_yang@tsinghua.edu.cn), 2018, Atomic Energy Press (52): : 2256 - 2262