Optimization of Removal of Cr(VI) from Wastewater by Electrocoagulation Process Using Response Surface Methodology

被引:8
|
作者
Kumar, Amit [1 ]
Basu, Debolina [1 ]
机构
[1] Motilal Nehru Natl Inst Technol Allahabad, Dept Civil Engn, Prayagraj 211004, India
关键词
Electrocoagulation; Hexavalent chromium; Response surface methodology; ALUMINUM; COAGULATION; CHROMIUM;
D O I
10.1061/(ASCE)HZ.2153-5515.0000723
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study investigated the removal of hexavalent chromium [Cr(VI)] from a simulated industrial effluent that used electrocoagulation (EC) technology. Experimental runs were conducted in a laboratory-scale batch EC cell with vertically rotating cylindrical aluminum (Al) electrodes, which imparted the required velocity to avoid a concentration gradient within the treatment unit. The independent variables, current, influent pH, rotational speed (rpm), and initial Cr(VI) concentration [Cr(VI)(i)], that affected Cr removal efficiency were optimized through a central composite design (CCD) that was initiated by the response surface methodology (RSM). The ANOVA factor of the CCD indicated that the investigated independent variables had a significant impact on the responses, such as Cr(VI) removal and specific electrical energy consumption (SEEC). Four factors, which each had three levels were considered: (1) Cr(VI)(i) (15-35 mg/L); (2) applied current (1-3 A); (3) initial pH (4-6); and (4) rotational speed of the electrode (40-100 rpm). High R-2 values were observed for Cr(VI) (98.12%) and SEEC (98.09%), which validated the regression equations that were generated in this study. Optimizing the performance factors for the treatment process was targeted to achieve maximum Cr(VI) removal and minimum SEEC. Under the optimum condition, the Cr(VI) removal efficiency, SEEC, and operating cost were 89.808%, 0.14 kW center dot h/g Cr(VI) removed, and USD 0.728/m(3), respectively. The optimum values that were obtained for the selected input variables were Cr(VI)(i) of 4.99 mg/L, current of 2.189 A, initial pH 4.5, and a rotational speed of 72.46 rpm.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Optimization of arsenic removal from drinking water by electrocoagulation batch process using response surface methodology
    Kobya, M.
    Demirbas, E.
    Gebologlu, U.
    Oncel, M. S.
    Yildirim, Y.
    DESALINATION AND WATER TREATMENT, 2013, 51 (34-36) : 6676 - 6687
  • [22] Removal of pollutants with determination of power consumption from landfill leachate wastewater using an electrocoagulation process: optimization using response surface methodology (RSM)
    Perumal Asaithambi
    Dejene Beyene
    Abdul Raman Abdul Aziz
    Esayas Alemayehu
    Applied Water Science, 2018, 8
  • [23] Removal of pollutants with determination of power consumption from landfill leachate wastewater using an electrocoagulation process: optimization using response surface methodology (RSM)
    Asaithambi, Perumal
    Beyene, Dejene
    Aziz, Abdul Raman Abdul
    Alemayehu, Esayas
    APPLIED WATER SCIENCE, 2018, 8 (02)
  • [24] Application of Response Surface Methodology for analysis and optimization of the operational parameters for turbidity removal from oily wastewater by electrocoagulation process
    Mohammed, Thamer Jasim
    Al-Zuheri, Hadeel Atiya
    INTERNATIONAL CONFERENCE ON MATERIALS ENGINEERING AND SCIENCE, 2018, 454
  • [25] Optimization of Electrocoagulation Process for Thallium Removal from Aqueous Solutions by Response Surface Methodology
    Fu X.
    Zhang L.
    Li L.
    Yang G.
    1600, Editorial Office of Chinese Journal of Rare Metals (44): : 530 - 539
  • [26] Optimization of electrocoagulation process to treat grey wastewater in batch mode using response surface methodology
    Thirugnanasambandham Karichappan
    Sivakumar Venkatachalam
    Prakash Maran Jeganathan
    Journal of Environmental Health Science and Engineering, 12
  • [27] Wastewater treatment using sono-electrocoagulation process: optimization through response surface methodology
    Arka, Andualem
    Dawit, Cherinet
    Befekadu, Adisu
    Debela, Seifu Kebede
    Asaithambi, Perumal
    SUSTAINABLE WATER RESOURCES MANAGEMENT, 2022, 8 (03)
  • [28] Optimization of electrocoagulation process to treat grey wastewater in batch mode using response surface methodology
    Karichappan, Thirugnanasambandham
    Venkatachalam, Sivakumar
    Jeganathan, Prakash Maran
    JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12
  • [29] Wastewater treatment using sono-electrocoagulation process: optimization through response surface methodology
    Andualem Arka
    Cherinet Dawit
    Adisu Befekadu
    Seifu Kebede Debela
    Perumal Asaithambi
    Sustainable Water Resources Management, 2022, 8
  • [30] Response Surface Methodology for Optimization of Simultaneous Cr (VI) and as (V) Removal from Contaminated Water by Nanofiltration Process
    Mojarrad, Mojtaba
    Noroozi, Amin
    Zeinivand, Ahmad
    Kazemzadeh, Pouya
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2018, 37 (01) : 434 - 443