Fundamental limitations of dual energy X-ray scanners for cargo content atomic number discrimination

被引:2
|
作者
Lalor, Peter [1 ,2 ]
Danagoulian, Areg [1 ]
机构
[1] MIT, Dept Nucl Sci & Engn, Cambridge, MA 02139 USA
[2] 138 Cherry St, Cambridge, MA 02139 USA
关键词
Dual energy radiography; Non-intrusive inspection; Atomic number discrimination; Nuclear security; INSPECTION;
D O I
10.1016/j.apradiso.2024.111201
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
To combat the risk of nuclear smuggling, radiography systems are deployed at ports to scan cargo containers for concealed illicit materials. Dual energy radiography systems enable a rough elemental analysis of cargo containers due to the Z -dependence of photon attenuation, allowing for improved material detection. This work studies the capabilities for atomic number discrimination using dual energy MeV systems by considering dual energy {6, 4} MeV, {10, 6} MeV, and {10, 4} MeV bremsstrahlung beams. Results of this analysis show that two different pure materials can sometimes produce identical transparency measurements, leading to a fundamental ambiguity when differentiating between materials of different atomic numbers. Previous literature has observed this property, but the extent of the limitation is poorly understood and the cause of the degeneracy is generally inadequately explained. This non -uniqueness property stems from competition between photoelectric absorption and pair production and is present even in systems with perfect resolution and zero statistical noise. These findings are validated through Monte Carlo transparency simulations. Results of this study show that currently deployed commercial radiographic systems are fundamentally incapable of distinguishing between high -Z nuclear materials and miscellaneous mid -Z cargo contents.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Fundamental limitations imposed by x-ray interactions on the modulation transfer function of existing x-ray detectors
    Hajdok, G
    Battista, J
    Cunningham, IA
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 1 - 15
  • [22] Overlapped objects discrimination using dual-energy, high energy X-ray imaging
    Li, Qinghua
    Li, Jianmin
    Wang, Xuewu
    Zhang, Li
    Kang, Kejun
    Zhong, Huaqiang
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2008, 48 (08): : 1256 - 1259
  • [23] Dual energy X-ray absorptiometry
    Winzenberg, Tania
    Jones, Graeme
    AUSTRALIAN FAMILY PHYSICIAN, 2011, 40 (1-2) : 43 - 44
  • [24] UPGRADING DUAL ENERGY X-RAY ABSORPTIOMETRY SCANNERS - DO NEW MODELS PROVIDE EQUIVALENT RESULTS
    HARPER, KD
    LOBAUGH, B
    KING, ST
    DREZNER, MK
    JOURNAL OF BONE AND MINERAL RESEARCH, 1992, 7 : S191 - S191
  • [25] X-RAY SPECTRA OF POLONIUM ATOMIC NUMBER 84
    PEED, WF
    BURKHART, LE
    STANIFORTH, RA
    FAUBLE, LG
    PHYSICAL REVIEW, 1957, 105 (02): : 588 - 589
  • [26] X-RAY ENERGIES FOR EFFECTIVE ATOMIC NUMBER DETERMINATION
    RUTHERFORD, RA
    PULLAN, BR
    ISHERWOOD, I
    NEURORADIOLOGY, 1976, 11 (01) : 23 - 28
  • [27] VARIATION OF PIONIC X-RAY INTENSITY WITH ATOMIC NUMBER
    BEER, GA
    DIXIT, MS
    MACDONALD, JA
    MASON, GR
    OLIN, A
    PEARCE, RM
    SABEV, C
    SPERRY, WC
    WIEGAND, C
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1978, 23 (07): : 927 - 927
  • [28] X-ray satellites of high atomic number elements
    Richtmyer, FK
    Kaufman, S
    PHYSICAL REVIEW, 1933, 44 (08): : 0605 - 0609
  • [29] IDENTIFICATION OF ATOMIC NUMBER OF NOBELIUM BY AN X-RAY TECHNIQUE
    DITTNER, PF
    BEMIS, CE
    HENSLEY, DC
    SILVA, RJ
    GOODMAN, CD
    PHYSICAL REVIEW LETTERS, 1971, 26 (17) : 1037 - &
  • [30] Assessment of meat fat content using dual energy X-ray absorption
    Brienne, JP
    Denoyelle, C
    Baussart, H
    Daudin, JD
    MEAT SCIENCE, 2001, 57 (03) : 235 - 244