Confocal Raman Spectroscopy for Assessing Bioequivalence of Topical Formulations

被引:9
|
作者
Iliopoulos, Fotis [1 ]
Tang, Chun Fung [1 ]
Li, Ziyue [1 ]
Rahma, Annisa [1 ,2 ]
Lane, Majella E. [1 ]
机构
[1] UCL Sch Pharm, Dept Pharmaceut, 29-39 Brunswick Sq, London WC1N 1AX, England
[2] Inst Teknol Bandung, Sch Pharm, Pharmaceut Dept, Bandung 40132, Indonesia
基金
英国工程与自然科学研究理事会;
关键词
Confocal Raman Spectroscopy; bioequivalence; topical formulations; skin delivery; IN-VITRO; PERCUTANEOUS-ABSORPTION; SKIN; IBUPROFEN; EQUIVALENCE; PERMEATION; ACID;
D O I
10.3390/pharmaceutics15041075
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
The evaluation of bioequivalence (BE) for topical dermatological drug products is challenging, and there has been significant interest from regulatory authorities in developing new BE methodologies in recent years. Currently, BE is demonstrated by comparative clinical endpoint studies; these are costly and time-consuming and often lack sensitivity and reproducibility. Previously, we reported excellent correlations between in vivo Confocal Raman Spectroscopy in human subjects and in vitro skin permeation testing (IVPT) with the human epidermis for skin delivery of ibuprofen and a number of excipients. The aim of the present proof-of-concept study was to evaluate CRS as a method to assess BE of topical products. Two commercially available formulations, Nurofen Max Strength 10% Gel and Ibuleve Speed Relief Max Strength 10% Gel, were selected for evaluation. Delivery of ibuprofen (IBU) to the skin was determined in vitro and in vivo by IVPT and CRS, respectively. The formulations examined were found to deliver comparable amounts of IBU across the skin over 24 h in vitro (p > 0.05). Additionally, the formulations resulted in similar skin uptake values measured with CRS in vivo, either at 1 h or 2 h after application (p > 0.05). This is the first study to report the capability of CRS for the demonstration of BE of dermal products. Future studies will focus on the standardisation of the CRS methodology for a robust and reproducible pharmacokinetic (PK)-based evaluation of topical BE.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Paper coating analysis by confocal Raman spectroscopy
    Kugge, Christian
    Greaves, Mark
    Hands, Kren
    Scholes, Fiona H.
    Vanderhoek, Nafty
    Ward, John
    APPITA JOURNAL, 2008, 61 (01): : 11 - 16
  • [22] A new paradigm in dermatopharmacokinetics - Confocal Raman spectroscopy
    Mateus, R.
    Abdalghafor, H.
    Oliveira, G.
    Hadgraft, J.
    Lane, M. E.
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2013, 444 (1-2) : 106 - 108
  • [23] Cryoporometry in Femtoliter Volumes by Confocal Raman Spectroscopy
    Piela, Katarzyna
    Tyrode, Eric C.
    Furo, Istvan
    LANGMUIR, 2019, 35 (26) : 8823 - 8828
  • [24] The Application of Confocal Raman Spectroscopy in Mussels Shell
    Cui N.-N.
    Du Z.-F.
    Zhang X.
    Luan Z.-D.
    Xi S.-C.
    Li L.-F.
    Wang M.-X.
    Wang B.
    Liang Z.-W.
    Liu J.
    Lian C.
    Yan J.
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2020, 40 (03): : 750 - 754
  • [25] In vivo confocal Raman spectroscopy: The window into the skin
    Crowther, J. M.
    Matts, P. J.
    INTERNATIONAL JOURNAL OF COSMETIC SCIENCE, 2024, 46 (04) : 603 - 609
  • [26] Combined in vivo confocal Raman spectroscopy and confocal microscopy of human skin
    Caspers, PJ
    Lucassen, GW
    Puppels, GJ
    BIOPHYSICAL JOURNAL, 2003, 85 (01) : 572 - 580
  • [27] The Application of Confocal Raman Spectroscopy in Mussels Shell
    Cui Nan-nan
    Du Zeng-feng
    Zhang Xin
    Luan Zhen-dong
    Xi Shi-chuan
    Li Lian-fu
    Wang Min-xiao
    Wang Bing
    Liang Zheng-wei
    Liu Jing
    Lian Chao
    Yan Jun
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2020, 40 (03) : 744 - 754
  • [28] In vivo confocal Raman spectroscopy of the human cornea
    Bauer, NJC
    Hendrikse, F
    March, WF
    CORNEA, 1999, 18 (04) : 483 - 488
  • [29] Bioequivalence of sparfloxacin formulations
    Khan, MK
    Singh, S
    Gupta, SB
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 1998, 358 (01) : R457 - R457
  • [30] Ingredients Tracking of Cosmetic Formulations in the Skin: A Confocal Raman Microscopy Investigation
    Foerster, Matthias
    Bolzinger, Marie-Alexandrine
    Ach, Delphine
    Montagnac, Gilles
    Briancon, Stephanie
    PHARMACEUTICAL RESEARCH, 2011, 28 (04) : 858 - 872