Inter-rater and intra-rater reliability of manual assessment of respiratory motion in patients with unilateral cervical radiculopathy: A cross-sectional study

被引:0
|
作者
Yoosefinejad, Amin Kordi [1 ,2 ]
Yousefiyan, Raziyeh [3 ]
Nazari, Raziyeh [3 ]
Rezaei, Iman [1 ,2 ,4 ]
机构
[1] Shiraz Univ Med Sci, Sch Rehabil Sci, Phys Therapy Dept, 1 Abivardi Ave,Chamran Blvd, Shiraz 713451733, Iran
[2] Shiraz Univ Med Sci, Rehabil Sci Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Student Res Comm, Sch Rehabil Sci, Shiraz, Iran
[4] Shiraz Univ Med Sci, Sch Rehabil Sci, Phys Therapy Dept, 1 Abivardi Ave,Chamran Blvd, Shiraz 71345, Iran
关键词
Breathing pattern; Cervical radiculopathy; Manual assessment of respiratory motion; Reliability; HEMIDIAPHRAGMATIC PARALYSIS; SPONDYLOSIS; DYSPNEA;
D O I
10.1016/j.ijosm.2024.100708
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Altered breathing pattern is a consequence of dysfunctional breathing. The respiratory pattern might be impaired in patients with cervical radiculopathy due to the involvement of common nerve roots with the phrenic nerve (C3- C5). Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of a technique for evaluating the breathing pattern known as manual assessment of respiratory motion (MARM) in patients with unilateral cervical radiculopathy. Design: Cross-sectional study. Setting: Rehabilitation Sciences Research Center Participants: Twenty-five patients with unilateral cervical radiculopathy aged 30-55 years participated in this study. Methods: Two experienced physical therapists investigated the respiratory pattern of the patients during normal and deep breathing using MARM, separately. Assessments were repeated again a week apart by each examiner. The inter- and intra-rater reliability of the MARM were calculated. Results: "Very good" inter-rater and intra-rater reliability were found with the MARM values during both normal and deep breathing patterns. (Inter-rater: ICC range = 0.71 to 0.82; intra-rater: ICC range = 0.72 to 0.80). Conclusions: MARM is a reliable clinical and research tool for assessing breathing patterns with very good interand intra-rater reliability in patients with unilateral cervical radiculopathy.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Intra-rater and inter-rater reliability of the process of obtaining cross-sectional area and echo intensity measurements of muscles from ultrasound images
    Sobolewski, Eric J.
    Wein, Leah D.
    Crow, Jacquelyn M.
    Carpenter, Kaitlyn M.
    JOURNAL OF ULTRASONOGRAPHY, 2021, 21 (84) : E7 - E11
  • [22] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Min, Ingi
    Woo, Hyeonseong
    Kim, Jae Yoon
    Kim, Tae-Lim
    Lee, Yookyung
    Chang, Won Kee
    Jung, Se Hee
    Lee, Woo Hyung
    Oh, Byung-Mo
    Han, Tai Ryoon
    Seo, Han Gil
    DYSPHAGIA, 2024, 39 (01) : 43 - 51
  • [23] Intra-rater and inter-rater reliability of six musculoskeletal preparticipatory screening tests
    Zumana, Nosipho
    Olivier, Benita
    Godlwana, Lonwabo
    Martin, Candice
    SOUTH AFRICAN JOURNAL OF PHYSIOTHERAPY, 2019, 75 (01)
  • [24] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid
    Roberts, Magdalea
    Mauldin, Samantha
    Rosa-Distefano, Gregoria
    AMERICAN JOURNAL OF OCCUPATIONAL THERAPY, 2019, 73 (04):
  • [25] Inter-Rater and Intra-Rater Reliability of the Kansas University Sitting Balance Scale
    Franc, Ingrid A.
    Mauldin, Samantha
    Roberts, Magdalena
    Rosa-DiStefano, Gregoria
    OCCUPATIONAL THERAPY IN HEALTH CARE, 2023, 37 (04) : 595 - 605
  • [26] Inter-rater and intra-rater reliability of the extended TUG test in elderly participants
    Bedoya-Belmonte, Juan Jose
    Rodriguez-Gonzalez, Maria del Mar
    Gonzalez-Sanchez, Manuel
    Pitarch, Jose Miguel Barreda
    Galan-Mercant, Alejandro
    Cuesta-Vargas, Antonio I.
    BMC GERIATRICS, 2020, 20 (01)
  • [27] Inter-rater and Intra-rater Reliability of the Videofluoroscopic Dysphagia Scale with the Standardized Protocol
    Ingi Min
    Hyeonseong Woo
    Jae Yoon Kim
    Tae-Lim Kim
    Yookyung Lee
    Won Kee Chang
    Se Hee Jung
    Woo Hyung Lee
    Byung-Mo Oh
    Tai Ryoon Han
    Han Gil Seo
    Dysphagia, 2024, 39 : 43 - 51
  • [28] Validation of Inter-Rater and Intra-Rater Reliability of Remote Dielectric Sensing Measurement
    Hori, Masakazu
    Imamura, Teruhiko
    Fukuo, Atsuko
    Fukui, Takuya
    Koi, Takatoshi
    Ueno, Yohei
    Onoda, Hiroshi
    Tanaka, Shuhei
    Ushijima, Ryuichi
    Sobajima, Mitsuo
    Fukuda, Nobuyuki
    Ueno, Hiroshi
    Kinugawa, Koichiro
    INTERNATIONAL HEART JOURNAL, 2022, 63 (01) : 73 - 76
  • [29] Inter-Rater and Intra-Rater Reliability of Sonographic Median Nerve and Wrist Measurements
    Gonzalez-Suarez, Consuelo B.
    Buenavente, Ma Lorraine D.
    Cua, Ronald Christopher A.
    Fidel, Maria Belinda C.
    Cabrera, Jan-Tyrone C.
    Regala, Carina Fatima G.
    JOURNAL OF MEDICAL ULTRASOUND, 2018, 26 (01) : 14 - 23
  • [30] Introducing a new definition of a near fall: Intra-rater and inter-rater reliability
    Maidan, I.
    Freedman, T.
    Tzemah, R.
    Giladi, N.
    Mirelman, A.
    Hausdorff, J. M.
    GAIT & POSTURE, 2014, 39 (01) : 645 - 647