Standardized viscosity as a source of error in computational fluid dynamic simulations of cerebral aneurysms

被引:3
|
作者
Fillingham, Patrick [1 ]
Belur, Neethi [1 ]
Sweem, Rebecca [1 ]
Barbour, Michael C. [2 ]
Marsh, Laurel M. M. [2 ]
Aliseda, Alberto [2 ]
Levitt, Michael R. [1 ,2 ,3 ]
机构
[1] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[2] Univ Washington, Dept Mech Engn, Seattle, WA USA
[3] Univ Washington, Dept Radiol, Seattle, WA USA
关键词
cerebral aneurysm; computational fluid dynamics; viscosity; BLOOD-VISCOSITY; MODELS; FLOW; RHEOLOGY;
D O I
10.1002/mp.16926
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundComputational fluid dynamics (CFD) simulations are a powerful tool for studying cerebral aneurysms, capable of evaluating hemodynamics in a way that is infeasible with imaging alone. However, the difficulty of incorporating patient-specific information and inherent obstacles of in vivo validation have limited the clinical usefulness of CFD of cerebral aneurysms. In this work we investigate the effect of using standardized blood viscosity values in CFD simulations of cerebral aneurysms when compared to simulations of the same aneurysms using patient-specific viscosity values derived from hematocrit measurements.PurposeThe objective of this work is to determine the level of error, on average, that is, caused by using standardized values of viscosity in CFD simulations of cerebral aneurysms. By quantifying this error, we demonstrate the need for incorporating patient-specific viscosity in future CFD investigations of cerebral aneurysms.MethodsCFD simulations of forty-one cerebral aneurysms were conducted using patient-specific boundary conditions. For each aneurysm two simulations were conducted, one utilizing patient-specific blood viscosity derived from hematocrit measurements and another using a standardized value for blood viscosity. Hemodynamic parameters such as wall shear stress (WSS), wall shear stress gradient (WSSG), and the oscillatory shear index (OSI) were calculated for each of the simulations for each aneurysm. Paired t-tests for differences in the time-averaged maps of these hemodynamic parameters between standardized and patient-specific viscosity simulations were conducted for each aneurysm. Bland-Altman analysis was used to examine the cohort-wide changes in the hemodynamic parameters. Subjects were broken into two groups, those with higher than standard viscosity and those with lower than standard viscosity. An unpaired t-test was used to compare the percent change in WSS, WSSG, and OSI between patient-specific and standardized viscosity simulations for the two cohorts. The percent changes in hemodynamic parameters were correlated against the direction and magnitude of percent change in viscosity, aneurysm size, and aneurysm location. For all t-tests, a Bonferroni-corrected significance level of 0.0167 was used.Results63.2%, 41.5%, and 48.7% of aneurysms showed statistically significant differences between patient-specific and standardized viscosity simulations for WSS, WSSG, and OSI respectively. No statistically significant difference was found in the percent changes in WSS, WSSG, and OSI between the group with higher than standard viscosity and those with lower than standard viscosity, indicating an increase in viscosity can cause either an increase or decrease in each of the hemodynamic parameters. On a study-wide level no significant bias was found in either direction for WSS, WSSG, or OSI between the simulation groups due to the bidirectional effect of changing viscosity. No correlation was found between percent change of viscosity and percent change of WSS, WSSG, or OSI, meaning an after-the-fact correction for patient-specific viscosity is not feasible.ConclusionStandardizing viscosity values in CFD of cerebral aneurysms has a large and unpredictable impact on the calculated WSS, WSSG, and OSI when compared to CFD simulations of the same aneurysms using a patient-specific viscosity. We recommend implementing hematocrit-based patient-specific blood viscosity values for all CFD simulations of cerebral aneurysms.
引用
收藏
页码:1499 / 1508
页数:10
相关论文
共 50 条
  • [31] Hemodynamic Localizations in Anterior Communicating Artery Aneurysms in Comparison With Middle Cerebral Artery Aneurysms With Computational Fluid Dynamics Analysis
    Fukuda, Shunichi
    Shimogonya, Yuji
    Fukuda, Miyuki
    Tsuskahara, Tetsuya
    STROKE, 2016, 47
  • [32] Variability of hemodynamic parameters using the common viscosity assumption in a computational fluid dynamics analysis of intracranial aneurysms
    Suzuki, Takashi
    Takao, Hiroyuki
    Suzuki, Takamasa
    Suzuki, Tomoaki
    Masuda, Shunsuke
    Dahmani, Chihebeddine
    Watanabe, Mitsuyoshi
    Mamori, Hiroya
    Ishibashi, Toshihiro
    Yamamoto, Hideki
    Yamamoto, Makoto
    Murayama, Yuichi
    TECHNOLOGY AND HEALTH CARE, 2017, 25 (01) : 37 - 47
  • [34] Numerical simulations of the discontinuous progression of cerebral aneurysms based on fluid-structure interactions study
    XiaoQi Ma
    YueShe Wang
    FangJun Yu
    GuoXiang Wang
    Science China Physics, Mechanics and Astronomy, 2010, 53 : 944 - 953
  • [35] Numerical simulations of the discontinuous progression of cerebral aneurysms based on fluid-structure interactions study
    Ma XiaoQi
    Wang YueShe
    Yu FangJun
    Wang GuoXiang
    SCIENCE CHINA-PHYSICS MECHANICS & ASTRONOMY, 2010, 53 (05) : 944 - 953
  • [36] Haemodynamic changes induced by intrasaccular packing on intracranial aneurysms: A computational fluid dynamic study
    Ugron, Adam
    Szikora, Istvan
    Paal, Gyoergy
    INTERVENTIONAL MEDICINE AND APPLIED SCIENCE, 2012, 4 (02): : 78 - 84
  • [37] Modeling anisotropic material property of cerebral aneurysms for fluid-structure interaction computational simulation
    Zhang, Hong
    Jiao, Yuanfeng
    Johnson, Erick
    Zhang, Yongjie
    Shimada, Kenji
    COMPUTATIONAL MODELLING OF OBJECTS REPRESENTED IN IMAGES: FUNDAMENTALS, METHODS AND APPLICATIONS III, 2012, : 261 - 266
  • [38] Computational fluid dynamic simulations for determination of ventricular workload in aortic arch obstructions
    Coogan, Jessica S.
    Chan, Frandics P.
    LaDisa, John F., Jr.
    Taylor, Charles A.
    Hanley, Frank L.
    Feinstein, Jeffrey A.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2013, 145 (02): : 489 - U535
  • [39] Comparison of Computational Fluid Dynamic Simulations with Experimental Jet Erosion Tests Results
    Mercier, F.
    Bonelli, S.
    Pinettes, P.
    Golay, F.
    Anselmet, F.
    Philippe, P.
    JOURNAL OF HYDRAULIC ENGINEERING, 2014, 140 (05)
  • [40] Assessing the credibility of a series of computational fluid dynamic simulations of open channel flow
    Hardy, RJ
    Lane, SN
    Ferguson, RI
    Parsons, DR
    HYDROLOGICAL PROCESSES, 2003, 17 (08) : 1539 - 1560