Reduction in water consumption in premise plumbing systems: Impacts on lead concentration under different water qualities

被引:1
|
作者
Hatam, Fatemeh [1 ]
Blokker, Mirjam [2 ]
Dore, Evelyne [1 ]
Prevost, Michele [1 ]
机构
[1] Polytech Montreal, Ind Chair Drinking Water, Dept Civil Geol & Min Engn, CP 6079,Succ Ctr Ville, Montreal, PQ H3C 3A7, Canada
[2] KWR Watercycle Res Inst, Groningenhaven 7, NL-3433 PE Nieuwegein, Netherlands
关键词
Water conservation; Lead service line; Lead dissolution model; Corrosion control; Water quality modelling; DRINKING-WATER; TAP WATER; SERVICE LINES; EXPOSURE; RELEASE; FULL; PB; WASHINGTON; CHILDREN;
D O I
10.1016/j.scitotenv.2023.162975
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water conservation measures are increasing in response to regulatory requirements addressing the need for lower environmental footprint and in response to water shortages. In households with lead service lines (LSLs), lowering consumption can adversely impact lead release as it will increase stagnation. Using a lead dissolution model and data from extensive pilot studies on excavated LSLs, the impact of adaptation to different water conservation strategies on dissolved lead contamination at the kitchen tap is assessed under three water qualities and three LSL lengths (3, 14 and 30 m) using hydraulic and water quality modelling. Consumers' behavioural variability is also assessed based on integration of EPANET and results of the stochastic water demand model SIMDEUM. Demand reduction increased the dissolved lead concentrations (Pbdiss) at the end of the LSL with mean values ranging from 28.4 to 63.3 mu g/L (without corrosion control) and from 4.6 to 9.9 mu g/L with corrosion control (addition of orthophosphate and pH adjustment). Adding orthophosphate (1 mg P/L) to the water reduces the mean Pbdiss values at the kitchen tap from 7.1 mu g/L to 1.2 mu g/L for a high water demand scenario and from 31.2 to 4.9 mu g/L for a low water demand scenario. Finally, the Integrated Exposure Uptake Biokinetic (IEUBK) model is used to predict the potential blood lead levels (BLLs) for children aged 0-84 months. Results showed that the orthophosphate addition of only 1 mg P/L can significantly decrease the proportion of children with a BLL >5 mu g/dL, from 82 % to 17 %, under the most extreme water conservation scenario studied, using the 90th percentile of Pbdiss concentrations during usage at kitchen tap. Wide variations of Pbdiss concentrations at the kitchen tap were calculated at times of use over a week (up to 155 mu g/L in lower demand scenarios, without corrosion control) showing evident limitations of single random daytime sampling.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Impacts of Effects of Deficit Irrigation Strategy on Water Use Efficiency and Yield in Cotton under Different Irrigation Systems
    Shukr, Hanan H.
    Pembleton, Keith G.
    Zull, Andrew F.
    Cockfield, Geoff J.
    AGRONOMY-BASEL, 2021, 11 (02):
  • [32] Water regime and water consumption of spring soft wheat varieties of different ecological groups under contrasting water availability conditions
    F. D. Samuilov
    L. A. Mukhitov
    Russian Agricultural Sciences, 2012, 38 (5-6) : 353 - 357
  • [33] Effect of rock fragments content on water consumption, biomass and water-use efficiency of plants under different water conditions
    Mi, Meixia
    Shao, Ming'an
    Liu, Bingxia
    ECOLOGICAL ENGINEERING, 2016, 94 : 574 - 582
  • [34] Corrosion control in water supply systems: Effect of pH, alkalinity, and orthophosphate on lead and copper leaching from brass plumbing
    Tam, Y. S.
    Elefsiniotis, P.
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2009, 44 (12): : 1251 - 1260
  • [35] Seasonal Risk Assessment of Water-Electricity Nexus Systems under Water Consumption Policy Constraint
    Mu, Mengfei
    Zhang, Zhenxing
    Cai, Ximing
    Tang, Quhong
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (07) : 3793 - 3802
  • [36] Water Consumption Characteristics and Water Use Efficiency of Flue-cured Tobacco Under Different Conditions of Irrigation
    Shao Xiao-hou
    Wang Qian
    Yuan You-bo
    Ding Fu-zhang
    MATERIAL SCIENCE, CIVIL ENGINEERING AND ARCHITECTURE SCIENCE, MECHANICAL ENGINEERING AND MANUFACTURING TECHNOLOGY II, 2014, 651-653 : 1388 - +
  • [37] Dynamic Changes in Physicochemical and Microbiological Qualities of Coconut Water during Postharvest Storage under Different Conditions
    Detudom, Rachatida
    Deetae, Pawinee
    Wei, Hu
    Boran, Hu
    Chen, Shiguo
    Siriamornpun, Sirithon
    Prakitchaiwattana, Cheunjit
    HORTICULTURAE, 2023, 9 (12)
  • [38] Release of drinking water contaminants and odor impacts caused by green building cross-linked polyethylene (PEX) plumbing systems
    Kelley, Keven M.
    Stenson, Alexandra C.
    Dey, Rajarashi
    Whelton, Andrew J.
    WATER RESEARCH, 2014, 67 : 19 - 32
  • [39] Impacts of urban water consumption under climate change: An adaptation measure of rainwater harvesting system
    Lin, Chia-Chun
    Liou, Kuan-Yu
    Lee, Mengshan
    Chiueh, Pei-Te
    JOURNAL OF HYDROLOGY, 2019, 572 : 160 - 168
  • [40] Modeled Impacts of Drinking Water Pb Reduction Scenarios on Children's Exposures and Blood Lead Levels
    Stanek, Lindsay W.
    Xue, Jianping
    Lay, Claire R.
    Helm, Erik C.
    Schock, Michael
    Lytle, Darren A.
    Speth, Thomas F.
    Zartarian, Valerie G.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2020, 54 (15) : 9474 - 9482