Eccentric compressive behavior of square concrete-encased concrete-filled double-skin steel tubular stub columns

被引:1
|
作者
Ding, Ji-nan [1 ]
Wang, Qinghe [2 ]
Ren, Qingxin [3 ]
Liu, Changyong [4 ]
Li, Minglun [2 ]
Zhang, Xinlong [5 ]
机构
[1] Shenyang Jianzhu Univ, Sch Management, 25 Hunnan Rd, Shenyang 110168, Liaoning, Peoples R China
[2] Shenyang Jianzhu Univ, Sch Civil Engn, 25 Hunnan Rd, Shenyang 110168, Liaoning, Peoples R China
[3] Foshan Univ, Sch Transportat & Civil Engn & Architecture, 33 Guangyun Rd, Foshan 528000, Guangdong, Peoples R China
[4] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[5] China Northeast Architectural Design & Res Inst CO, Shenyang 110000, Liaoning, Peoples R China
基金
中国国家自然科学基金;
关键词
Concrete-encased concrete-filled double-skin; steel tubular stub column; Experimental evaluation; Numerical simulation; Eccentric compressive performance; Simplified design method; CFST COLUMNS; STRENGTH; INNER;
D O I
10.1016/j.jcsr.2024.108489
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-encased concrete-filled double-skin steel tubular (CFDST) stub columns serve as structural members, encompassing an exterior reinforced concrete (RC) component alongside an internal CFDST component. In this paper, the eccentric compressive behavior of such stub columns was investigated. To this end, specimens with varying diameter-to-width ratios do/w and eccentricity ratios e/w were examined; their failure process, failure modes, strain distributions, and representative mechanical performance were recorded and analyzed. Based on the experimental results, the specimens' failure process transitions through four stages: elastic, elastic-plastic, descending, and stabilizing. With do/w escalating from 0.5 to 0.7, the eccentric compressive strength, flexural stiffness, and displacement ductility index improved by 16.1%, 15.2%, and 37.2%, respectively. Subsequently, a detailed finite element model (FEM) was established to analyze the eccentric performance of the concreteencased CFDST stub columns. Following the FEM reliability validation, the working characteristics of such stub columns in the balanced failure mode were elucidated. The full-range analyses were carried out under failure modes controlled by compression and tension to unveil the loading distribution mechanisms. Moreover, the impacts of parameters like concrete compressive strength, diameter-to-width ratio, and steel tube yield strength on the Nu-Mu relation curves were quantified, ascertaining the key influencing factors. Finally, a formula was suggested to predict the corresponding eccentric compressive strength. Following the superposition principle and limit equilibrium theory, the simplified design equations put forth yielded satisfactory predictions based on the experimental and numerical results.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Numerical Modeling of Concrete-Filled Double-Skin Steel Square Tubular Columns under Blast Loading
    Zhang, Fangrui
    Wu, Chengqing
    Zhao, Xiao-Ling
    Li, Zhong-Xian
    Heidarpour, Amin
    Wang, Hongwei
    [J]. JOURNAL OF PERFORMANCE OF CONSTRUCTED FACILITIES, 2015, 29 (05)
  • [32] Concrete-filled double-skin tubular columns under fire
    Yang, Y. F.
    Han, L. -H.
    [J]. MAGAZINE OF CONCRETE RESEARCH, 2008, 60 (03) : 211 - 222
  • [33] Finite element analysis on the capacity of circular concrete-filled double-skin steel tubular (CFDST) stub columns
    Pagoulatou, M.
    Sheehan, T.
    Dai, X. H.
    Lam, D.
    [J]. ENGINEERING STRUCTURES, 2014, 72 : 102 - 112
  • [34] Nonlinear analysis of square concrete-filled double-skin steel tubular columns under axial compression
    Ayough, Pouria
    Sulong, N. H. Ramli
    Ibrahim, Zainah
    Hsiao, Po-Chien
    [J]. ENGINEERING STRUCTURES, 2020, 216 (216)
  • [35] Behavior of octagonal concrete-filled double-skin steel tube stub columns under axial compression
    Alqawzai, Shagea
    Chen, Kang
    Shen, Le
    Ding, Miao
    Yang, Bo
    Elchalakani, Mohamed
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 170
  • [36] Compressive behavior of steel-reinforced concrete-filled circular steel tubular stub columns
    Zhang, Tao
    Ding, Fa-xing
    Liu, Xue-mei
    Yu, Zhi-wu
    [J]. STRUCTURES, 2020, 28 : 863 - 877
  • [37] Axial compressive behavior of stiffened square concrete-filled steel tubular stub columns under axial load
    Zheng, Xin-Zhi
    Cai, Jian
    Zheng, Xin-Hua
    [J]. Huanan Ligong Daxue Xuebao/Journal of South China University of Technology (Natural Science), 2013, 41 (10): : 126 - 134
  • [38] Numerical analysis of square concrete-filled double skin steel tubular columns with rubberized concrete
    Ayough, Pouria
    Ibrahim, Zainah
    Sulong, N. H. Ramli
    Hsiao, Po-Chien
    Elchalakani, Mohamed
    [J]. STRUCTURES, 2021, 32 : 1026 - 1047
  • [39] Tests and mechanics model for concrete-filled double skin steel tubular stub columns
    Tao, Z
    Han, LH
    [J]. ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 899 - 905
  • [40] Analytical behaviour of concrete-filled double skin steel tubular (CFDST) stub columns
    Huang, Hong
    Han, Lin-Hai
    Tao, Zhong
    Zhao, Xiao-Ling
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2010, 66 (04) : 542 - 555