Urinary bladder phantom mimicking mechanical properties and pressure during filling

被引:4
|
作者
Verstraeten, Maxime [1 ]
Kheir, George Bou [2 ]
Vande Perre, Louis [1 ]
Raffoul, Romain [1 ]
Cerda, Javier Chavez [1 ]
Delchambre, Alain [1 ]
Roumeguere, Thierry [3 ]
Vanhoestenberghe, Anne [4 ]
Nonclercq, Antoine [1 ]
机构
[1] Univ Libre Bruxelles, BEAMS Biomechatron Dept, Brussels, Belgium
[2] Ghent Univ Hosp, Dept Urol, ERN Accredited Ctr, Ghent, Belgium
[3] Univ Libre Bruxelles, Hop Erasme, Hop Univ Bruxelles, Dept Urol, Brussels, Belgium
[4] Kings Coll London, Sch Biomed Engn & Imaging Sci, MAISI Facil, London, England
关键词
realistic bladder model; cystometrogram (CMG); pressure-volume curve; bladder pressure monitoring; silicone rubber; 3D-printed water-soluble molds; WALL;
D O I
10.1088/2057-1976/ace449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Phantoms that mimic healthy or diseased organ properties can complement animal models for surgical planning, training, and medical device development. If urodynamic studies rely on pressure-volume curves to assess lower urinary tract symptoms, there is an unsatisfied need for a bladder phantom that accurately mimics the bladder stretching capabilities and compliant behaviour during physiological filling. Approach. We demonstrate the suitability of water-soluble 3D-printed moulds as a versatile method to fabricate accurate phantoms with anatomical structures reconstructed from medical images. We report a phantom fabricated with silicone rubber. A wire net limits the silicone expansion to model the cystometric capacity. A mathematical model describes the pressure increase due to passive hyperelastic properties. Main results. The phantom reproduces the bladder's mechanical properties during filling. The pressure-volume curve measured on the phantom is typical of cystometric studies, with a compliance of 25.2 +/- 1 ml cmH(2)O(-1). The root-mean-square error between the theoretical model and experimental data is 2.7 cmH(2)O. The compliance, bladder wall thickness, cystometric capacity and pressure near the cystometric capacity of the phantom can be tuned to mimic various pathologies or human variability. Significance. The manufacturing method is suitable for fabricating bladder and other soft and hollow organ phantoms. The mathematical model provides a method to determine design parameters to model healthy or diseased bladders. Soft hollow organ phantoms can be used to complement animal experimentations for developing and validating medical devices aiming to be anchored on these organs or monitor their activity through pressure and strain measurement.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] PHANTOM URINARY-BLADDER PAIN - CASE-REPORT
    BRENA, SF
    SAMMONS, EE
    PAIN, 1979, 7 (02) : 197 - 201
  • [42] Modeling the influence of acute changes in bladder elasticity on pressure and wall tension during filling
    Habteyes, Firdaweke G.
    Komari, S. Omid
    Nagle, Anna S.
    Klausner, Adam P.
    Heise, Rebecca L.
    Ratz, Paul H.
    Speich, John E.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 71 : 192 - 200
  • [43] Optofluidic phantom mimicking optical properties of porcine livers
    Long, Ruiqi
    King, Travis
    Akl, Tony
    Ericson, M. Nance
    Wilson, Mark
    Cote, Gerard L.
    McShane, Michael J.
    BIOMEDICAL OPTICS EXPRESS, 2011, 2 (07): : 1877 - 1892
  • [44] STUDY OF A NOVEL BIOREACTOR TO SIMULATE URINARY BLADDER MECHANICAL PROPERTIES AND COMPLIANCE FOR BLADDER FUNCTIONAL TISSUE ENGINEERING
    Wang, K.
    Wei, X.
    Li, H.
    EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 214 - 214
  • [45] Reproducibility of the bladder shape and bladder shape changes during filling
    Lotz, HT
    van Herk, M
    Betgen, A
    Pos, F
    Lebesque, JV
    Remeijer, P
    MEDICAL PHYSICS, 2005, 32 (08) : 2590 - 2597
  • [46] Reproducibility of the bladder shape and shape changes during bladder filling
    Lotz, H
    Remeijer, P
    van Herk, M
    Betgen, A
    Pos, F
    Lebesque, J
    RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S224 - S225
  • [47] ACTIVE MECHANICAL-PROPERTIES OF THE SMOOTH-MUSCLE OF THE URINARY-BLADDER
    GRIFFITHS, DJ
    VANMASTRIGT, R
    VANDUYL, WA
    COOLSAET, BLRA
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1979, 17 (03) : 281 - 290
  • [48] Impairment of urinary bladder mechanical properties in rat model of type 2 diabetes
    Philyppov, Igor B.
    Sotkis, Ganna, V
    Danshyna, Anastasiia O.
    Yelyashov, Semen, I
    Sharopov, Bizhan R.
    Shuba, Yaroslav M.
    NEUROUROLOGY AND URODYNAMICS, 2022, 41 (08) : 1670 - 1678
  • [49] ATP RELEASE DURING BLADDER FILLING IN WOMEN WITH BLADDER OVERSENSITIVITY
    Cheng, Ying
    Mansfield, Kylie
    Burcher, Elizabeth
    Moore, Kate
    JOURNAL OF UROLOGY, 2012, 187 (04): : E934 - E935
  • [50] A psychophysical study of discomfort produced by repeated filling of the urinary bladder
    Ness, TJ
    Richter, HE
    Varner, RE
    Fillingim, RB
    PAIN, 1998, 76 (1-2) : 61 - 69