Urinary bladder phantom mimicking mechanical properties and pressure during filling

被引:4
|
作者
Verstraeten, Maxime [1 ]
Kheir, George Bou [2 ]
Vande Perre, Louis [1 ]
Raffoul, Romain [1 ]
Cerda, Javier Chavez [1 ]
Delchambre, Alain [1 ]
Roumeguere, Thierry [3 ]
Vanhoestenberghe, Anne [4 ]
Nonclercq, Antoine [1 ]
机构
[1] Univ Libre Bruxelles, BEAMS Biomechatron Dept, Brussels, Belgium
[2] Ghent Univ Hosp, Dept Urol, ERN Accredited Ctr, Ghent, Belgium
[3] Univ Libre Bruxelles, Hop Erasme, Hop Univ Bruxelles, Dept Urol, Brussels, Belgium
[4] Kings Coll London, Sch Biomed Engn & Imaging Sci, MAISI Facil, London, England
关键词
realistic bladder model; cystometrogram (CMG); pressure-volume curve; bladder pressure monitoring; silicone rubber; 3D-printed water-soluble molds; WALL;
D O I
10.1088/2057-1976/ace449
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective. Phantoms that mimic healthy or diseased organ properties can complement animal models for surgical planning, training, and medical device development. If urodynamic studies rely on pressure-volume curves to assess lower urinary tract symptoms, there is an unsatisfied need for a bladder phantom that accurately mimics the bladder stretching capabilities and compliant behaviour during physiological filling. Approach. We demonstrate the suitability of water-soluble 3D-printed moulds as a versatile method to fabricate accurate phantoms with anatomical structures reconstructed from medical images. We report a phantom fabricated with silicone rubber. A wire net limits the silicone expansion to model the cystometric capacity. A mathematical model describes the pressure increase due to passive hyperelastic properties. Main results. The phantom reproduces the bladder's mechanical properties during filling. The pressure-volume curve measured on the phantom is typical of cystometric studies, with a compliance of 25.2 +/- 1 ml cmH(2)O(-1). The root-mean-square error between the theoretical model and experimental data is 2.7 cmH(2)O. The compliance, bladder wall thickness, cystometric capacity and pressure near the cystometric capacity of the phantom can be tuned to mimic various pathologies or human variability. Significance. The manufacturing method is suitable for fabricating bladder and other soft and hollow organ phantoms. The mathematical model provides a method to determine design parameters to model healthy or diseased bladders. Soft hollow organ phantoms can be used to complement animal experimentations for developing and validating medical devices aiming to be anchored on these organs or monitor their activity through pressure and strain measurement.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] MECHANICAL PROPERTIES OF URINARY BLADDER
    ALEXANDER, RS
    AMERICAN JOURNAL OF PHYSIOLOGY, 1971, 220 (05): : 1413 - +
  • [2] The effect of urinary bladder shape on its mechanics during filling
    Bioengineering Graduate Group, University of California, Berkeley, CA 94720, United States
    J. BIOMECH., 6 (725-732):
  • [3] Mechanical properties of (urinary bladder) smooth muscle
    Van Mastrigt, R
    JOURNAL OF MUSCLE RESEARCH AND CELL MOTILITY, 2002, 23 (01) : 53 - 57
  • [4] Mechanical properties of (urinary bladder) smooth muscle
    R. Van Mastrigt
    Journal of Muscle Research & Cell Motility, 2002, 23 : 53 - 57
  • [5] Biaxial mechanical properties of the urinary bladder wall
    Sacks, Michael S.
    Gloeckner, D. Claire
    Chancellor, Michael
    DeGroat, William C.
    Schneck, Francis X.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 307 - 308
  • [6] A Dynamic Ultrasound Phantom with Tissue-Mimicking Mechanical and Acoustic Properties
    Fernandez, Sara V.
    Kim, Jin-Hoon
    Sadat, David
    Marcus, Colin
    Suh, Emma
    Mclntosh, Rachel
    Shah, Aastha
    Dagdeviren, Canan
    ADVANCED SCIENCE, 2024, 11 (22)
  • [7] Endometriosis localized to urinary bladder wall mimicking urinary bladder carcinoma
    Genc, Mine
    Genc, Berhan
    Karaarslan, Serap
    Solak, Aynur
    Saracoglu, Musa
    ARCHIVIO ITALIANO DI UROLOGIA E ANDROLOGIA, 2014, 86 (03) : 233 - 234
  • [8] THE EFFECT OF URINARY-BLADDER SHAPE ON ITS MECHANICS DURING FILLING
    DAMASER, MS
    LEHMAN, SL
    JOURNAL OF BIOMECHANICS, 1995, 28 (06) : 725 - 732
  • [9] AMBULATORY MONITORING OF BLADDER AND DETRUSOR PRESSURE DURING NATURAL FILLING
    GRIFFITHS, CJ
    ASSI, MS
    STYLES, RA
    RAMSDEN, PD
    NEAL, DE
    JOURNAL OF UROLOGY, 1989, 142 (03): : 780 - 784
  • [10] FILLING DEFECT IN URINARY-BLADDER
    KORSOWER, JM
    REEDER, MM
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1975, 231 (04): : 408 - 409