Repositioned versus exchanged flanged intraocular lens fixation for intraocular lens dislocation

被引:3
|
作者
Kang, Yong Koo [1 ]
Park, Dong Ho [1 ]
Ryu, Gahyung [2 ]
Kim, Hong Kyun [1 ]
Kim, Dong Hyun [1 ]
Do, Jae Rock [1 ]
机构
[1] Kyungpook Natl Univ, Kyungpook Natl Univ Hosp, Sch Med, Dept Ophthalmol, 130 Dongdeok Ro, Daegu 41944, South Korea
[2] Nune Eye Hosp, Seoul, South Korea
基金
新加坡国家研究基金会;
关键词
IMPLANTATION; ABSENCE;
D O I
10.1038/s41598-024-54694-6
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This study aimed to compare the outcomes of flanged intraocular lens (IOL) fixation with new IOL exchange after dislocated IOL removal and repositioned dislocated IOL in patients with IOL dislocation. Eighty-nine eyes that underwent flanged IOL fixation were retrospectively included, with 51 eyes in the exchanged IOL group and 38 eyes in the repositioned IOL group. In both groups, best-corrected visual acuity (BCVA) improved at 1, 3, 6, and 12 months postoperatively and did not differ between the two groups at any of these time points. However, at 1 week postoperatively, BCVA in the repositioned IOL group improved compared with baseline, whereas that in the exchanged IOL group did not. Moreover, there were lesser changes in the corneal endothelial cell density (ECD) and corneal astigmatism in the repositioned IOL group than in the exchanged IOL group. The IOL positions, including IOL tilt and IOL decentration, were not different between the groups. Flanged IOL fixation with new IOL exchange and with repositioned dislocated IOL for patients with IOL dislocation had similar visual outcomes and IOL position. However, the latter had a smaller corneal ECD decrease and astigmatic change. This technique was effective in treating IOL dislocation while minimizing corneal injury.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Fusion-Flanged Intrascleral Intraocular Lens Fixation Technique: Simple, Safe, Efficient
    Piyasoonthorn, Pratan
    Gacivut, Puntanarach
    CORNEA, 2024, 43 (06) : 795 - 798
  • [42] Adaptation of flanged intrascleral intraocular lens fixation technique with a glaucoma valve in aphakic glaucoma
    Pathak-Ray, Vanita
    Malhotra, Varun
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (08): : 1092 - 1093
  • [43] Sutureless Trocar-Cannula-Based Transconjunctival Flanged Intrascleral Intraocular Lens Fixation
    Walsh, Mark K.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (11): : 2191 - 2194
  • [44] INTRAOCULAR-LENS DISLOCATION IN THE BAG
    PARK, SB
    AQUAVELLA, JV
    SASS, WO
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (04): : 546 - 547
  • [45] In-the-bag intraocular lens dislocation
    Gross, JG
    Kokame, GT
    Weinberg, DV
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (04) : 630 - 635
  • [46] In-the-bag intraocular lens dislocation
    Ahmed, IIK
    Crandall, AS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (05) : 952 - 953
  • [47] SUBCONJUNCTIVAL DISLOCATION OF INTRAOCULAR LENS IMPLANT
    BIEDNER, B
    ROTHKOFF, L
    BLUMENTHAL, M
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1977, 84 (02) : 265 - 266
  • [48] DISLOCATION OF A PHAKIC INTRAOCULAR-LENS
    RISCO, JM
    CAMERON, JA
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1994, 118 (05) : 666 - 667
  • [49] Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation
    Tokuhisa, Teruaki
    Watanabe, Tomoyuki
    Watanabe, Akira
    Nakano, Tadashi
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (04) : 1213 - 1220
  • [50] Refractive error induced by intraocular lens tilt after intrascleral intraocular lens fixation
    Teruaki Tokuhisa
    Tomoyuki Watanabe
    Akira Watanabe
    Tadashi Nakano
    International Ophthalmology, 2022, 42 : 1213 - 1220