Soil thermal imbalance analysis of ground source heat pump system of residential and office buildings in sixteen cities

被引:6
|
作者
Hu, Zicheng [1 ]
Li, Wanfeng [1 ]
Zhang, Haiyan [1 ]
Liu, Xiaoyuan [1 ]
Geng, Shuwen [1 ]
Han, Yuchen [1 ]
Ge, Fenghua [1 ]
机构
[1] Jiangsu Univ, Sch Energy & Power Engn, Zhenjiang 212013, Jiangsu, Peoples R China
关键词
Soil thermal imbalance; Solar energy; Air energy; Soil heat storage; Building type; Cold region; Ground source heat pump; FEASIBILITY; PERFORMANCE;
D O I
10.1016/j.renene.2023.119860
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To recognize the influence of building type and climate region on the soil thermal imbalance and the feasibility of using renewable energy to solve the soil thermal imbalance of ground source heat pump (GSHP), residential and office buildings in sixteen cities in China and five methods of soil heat storage were selected. The characteristics and optimal solutions of soil thermal imbalance in different buildings and cities were analyzed. The results show that most residential buildings have serious soil thermal imbalance rate (TIR), while most office buildings have moderate soil TIR. Soil heat storage is needed for all residential buildings in sixteen cities and office buildings in nine cities. By integrating solar collector (SC), heat source tower (HST) and air-source heat compensator (AHC) with GSHP, the soil cold accumulation of residential buildings in sixteen cities can be solved by SC&HST-GSHP system in Harbin and Changchun, SC&AHC-GSHP system in Hohhot and Urumqi and SC-GSHP system in other twelve cities. While the soil cold accumulation of office buildings in nine cities can be solved by SC-GSHP system in Taiyuan, HST-GSHP system in Harbin, Changchun and Xining, AHC-GSHP system in Hohhot and Urumqi, SC&HST-GSHP system in Shenyang and SC&AHC-GSHP system in Lanzhou and Lhasa.
引用
收藏
页数:18
相关论文
共 50 条
  • [41] Optimization of thermal performance of a building with ground source heat pump system
    Zogou, Olympia
    Stamatelos, Anastassios
    ENERGY CONVERSION AND MANAGEMENT, 2007, 48 (11) : 2853 - 2863
  • [42] Soil thermal behavior of a horizontal ground source heat system
    Thomas, H. R.
    Hepburn, B. D. P.
    Sedighi, M.
    COUPLED PHENOMENA IN ENVIRONMENTAL GEOTECHNICS: FROM THEORETICAL AND EXPERIMENTAL RESEARCH TO PRACTICAL APPLICATIONS, 2013, : 525 - 530
  • [43] Experimental and modeling analysis of a ground source heat pump system
    Montagud, Carla
    Miguel Corberan, Jose
    Ruiz-Calvo, Felix
    APPLIED ENERGY, 2013, 109 : 328 - 336
  • [44] An office building energy-saving design of ground source heat pump system
    Yu, Wei
    Zhu, Chunying
    Gao, Menghui
    ADVANCES IN CIVIL AND INDUSTRIAL ENGINEERING, PTS 1-4, 2013, 353-356 : 3093 - 3096
  • [45] Soil Thermal Balance Analysis for a Ground Source Heat Pump System in a Hot-Summer and Cold-Winter Region
    Zhao, Zhongchao
    Shen, Rendong
    Feng, Weixian
    Zhang, Yong
    Zhang, Yanrui
    ENERGIES, 2018, 11 (05)
  • [46] Ground source heat pump carbon emissions and ground-source heat pump systems for heating and cooling of buildings: A review
    Ahmadi, Mohammad Hossein
    Ahmadi, Mohammad Ali
    Sadaghiani, Mirhadi S.
    Ghazvini, Mahyar
    Shahriar, Sadegh
    Nazari, Mohammad Alhuyi
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2018, 37 (04) : 1241 - 1265
  • [47] Development of a Residential Ground-Source Integrated Heat Pump
    Rice, Keith
    Baxter, Van
    Hern, Shawn
    McDowell, Tim
    Munk, Jeffrey
    Shen, Bo
    2013 ASHRAE WINTER CONFERENCE, 2013,
  • [48] Performance analysis of air source heat pump system for office building
    Dongwon Han
    Young Soo Chang
    Yongchan Kim
    Journal of Mechanical Science and Technology, 2016, 30 : 5257 - 5268
  • [49] Performance analysis of air source heat pump system for office building
    Han, Dongwon
    Chang, Young Soo
    Kim, Yongchan
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (11) : 5257 - 5268
  • [50] Underground Thermal Properties Analysis for Ground Source Heat Pump Application
    Cui Wenzhi
    Zhou Shiyu
    Peng Qingyuan
    2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 470 - 473