Dual-Energy CT Evaluation of Gastrointestinal Bleeding

被引:6
|
作者
Dane, Bari [1 ]
Gupta, Avneesh [2 ]
Wells, Michael L. [3 ]
Anderson, Mark A. [5 ]
Fidler, Jeff L. [3 ]
Naringrekar, Haresh V. [6 ]
Allen, Brian C. [8 ]
Brook, Olga R. [9 ]
Bruining, David H. [4 ]
Gee, Michael S. [5 ]
Grand, David J. [10 ]
Kastenberg, David [7 ]
Khandelwal, Ashish [3 ]
Sengupta, Neil [11 ]
Soto, Jorge A. [2 ]
Guglielmo, Flavius F. [6 ]
机构
[1] NYU Langone Hlth, Dept Radiol, 660 1st Ave, New York, NY 10016 USA
[2] Boston Univ, Dept Radiol, Med Ctr, Boston, MA USA
[3] Mayo Clin, Dept Radiol, Rochester, MN USA
[4] Mayo Clin, Div Gastroenterol & Hepatol, Rochester, MN USA
[5] Harvard Med Sch, Dept Radiol, Massachusetts Gen Hosp, Boston, MA USA
[6] Thomas Jefferson Univ, Dept Radiol, Philadelphia, PA USA
[7] Thomas Jefferson Univ, Div Gastroenterol, Philadelphia, PA USA
[8] Duke Univ, Dept Radiol, Med Ctr, Durham, NC USA
[9] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA USA
[10] Brown Univ, Dept Diagnost Imaging, Warren Alpert Med Sch, Rhode Isl Hosp, Providence, RI USA
[11] Univ Chicago, Div Gastroenterol, Chicago, IL USA
关键词
IODINE QUANTIFICATION; RENAL LESIONS; ANGIOGRAPHY; THRESHOLD; PITFALLS; PEARLS; IMAGES;
D O I
10.1148/rg.220192
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gastrointestinal (GI) bleeding is a potentially life-threatening condition accounting for more than 300 000 annual hospitalizations. Multidetector abdominopelvic CT angiography is commonly used in the evaluation of patients with GI bleeding. Given that many patients with severe overt GI bleeding are unlikely to tolerate bowel preparation, and inpatient colonoscopy is frequently limited by suboptimal preparation obscuring mucosal visibility, CT angiography is recommended as a first-line diagnostic test in patients with severe hematochezia to localize a source of bleeding. Assessment of these patients with conventional single-energy CT systems typically requires the performance of a noncontrast series followed by imaging during multiple postcontrast phases. Dual-energy CT (DECT) offers several potential advantages for performing these examinations. DECT may eliminate the need for a noncontrast acquisition by allowing the creation of virtual noncontrast (VNC) images from contrast-enhanced data, affording significant radiation dose reduction while maintaining diagnostic accuracy. VNC images can help radiologists to differentiate active bleeding, hyper-attenuating enteric contents, hematomas, and enhancing masses. Additional postprocessing techniques such as low-kiloelectron voltage virtual monoenergetic images, iodine maps, and iodine overlay images can increase the conspicuity of contrast material extravasation and improve the visibility of subtle causes of GI bleeding, thereby increasing diagnostic confidence and assisting with problem solving. GI bleeding can also be diagnosed with routine single-phase DECT scans by constructing VNC images and iodine maps. Radiologists should also be aware of the potential pitfalls and limitations of DECT. (c) RSNA, 2023 center dot radiographics.rsna.org
引用
收藏
页数:18
相关论文
共 50 条
  • [21] EVALUATION OF THE DUAL-ENERGY METHOD IN QUANTITATIVE CT INVESTIGATIONS OF THE BRAIN
    VOGL, G
    KIWI, A
    VOIGT, K
    RADIOLOGE, 1988, 28 (11): : 503 - 506
  • [22] Clinical Utility of Dual-Energy CT for Evaluation of Tophaceous Gout
    Desai, Madhura A.
    Peterson, Jeffrey J.
    Garner, Hillary Warren
    Kransdorf, Mark J.
    RADIOGRAPHICS, 2011, 31 (05) : 1365 - 1375
  • [23] Dual-Energy CT in the Evaluation of Intracerebral Hemorrhage of Unknown Origin: Differentiation between Tumor Bleeding and Pure Hemorrhage
    Kim, S. J.
    Lim, H. K.
    Lee, H. Y.
    Choi, C. G.
    Lee, D. H.
    Suh, D. C.
    Kim, S. M.
    Kim, J. K.
    Krauss, B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (05) : 865 - 872
  • [24] Gastrointestinal Applications of Iodine Quantification Using Dual-Energy CT: A Systematic Review
    Xu, Jack Junchi
    Taudorf, Mikkel
    Ulriksen, Peter Sommer
    Achiam, Michael Patrick
    Resch, Timothy Andrew
    Nielsen, Michael Bachmann
    Lonn, Lars Birger
    Hansen, Kristoffer Lindskov
    DIAGNOSTICS, 2020, 10 (10)
  • [25] Dual-source, dual-energy multidetector CT for the evaluation of pancreatic tumours
    Chu, A. J.
    Lee, J. M.
    Lee, Y. J.
    Moon, S. K.
    Han, J. K.
    Choi, B. I.
    BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1018): : E891 - E898
  • [26] Dual-Energy CT for Diagnostic CT Colonography
    Karcaaltincaba, Musturay
    Ozdeniz, Ilknur
    RADIOGRAPHICS, 2014, 34 (03) : 847 - 847
  • [27] The assessment of intracranial bleeding with virtual unenhanced imaging by means of dual-energy CT angiography
    Ferda, Jiri
    Novak, Milan
    Mirka, Hynek
    Baxa, Jan
    Ferdova, Eva
    Bednarova, Alena
    Flohr, Thomas
    Schmidt, Bernhard
    Klotz, Ernst
    Kreuzberg, Boris
    EUROPEAN RADIOLOGY, 2009, 19 (10) : 2518 - 2522
  • [28] Dual-Energy CT and Spot Sign
    Vargas, M. I.
    Lovblad, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (10) : E63 - E63
  • [29] The assessment of intracranial bleeding with virtual unenhanced imaging by means of dual-energy CT angiography
    Jiří Ferda
    Milan Novák
    Hynek Mírka
    Jan Baxa
    Eva Ferdová
    Alena Bednářová
    Thomas Flohr
    Bernhard Schmidt
    Ernst Klotz
    Boris Kreuzberg
    European Radiology, 2009, 19 : 2518 - 2522
  • [30] Dual-Energy CT of Intrahepatic Splenosis
    Zhang, Hui-Hui
    Tan, Xian-Zheng
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2024, 223 (06)