Solid-contact polymeric membrane ion-selective electrodes using a covalent organic framework@reduced graphene oxide composite as ion-to-electron transducer

被引:5
|
作者
Zhang, Wenting [1 ,2 ]
Li, Jinghui [2 ]
Qin, Wei [2 ,3 ,4 ]
机构
[1] Yantai Univ, Coll Chem & Chem Engn, Yantai 264005, Shandong, Peoples R China
[2] Chinese Acad Sci, Yantai Inst Coastal Zone Res YIC, CAS Key Lab Coastal Environm Proc & Ecol Remediat, Shandong Key Lab Coastal Environm Proc,YICCAS, Yantai 264003, Shandong, Peoples R China
[3] Qingdao Natl Lab Marine Sci & Technol, Qingdao 266237, Shandong, Peoples R China
[4] Chinese Acad Sci, Ctr Ocean Mega Sci, Qingdao 266071, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
Covalent organic framework; Solid contact; Ion-selective electrode; Reproducibility; Stability; COEFFICIENTS;
D O I
10.1016/j.talanta.2023.124444
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A solid-contact ion-selective electrode (SC-ISE) based on a covalent organic framework@reduced graphene oxide (rGO) composite is proposed. The composite can be synthesized through the polycondensation of 1,3,5-triformyl-phloroglucinol (TFP) and 2,6-diaminoanthraquinone (DAAQ) on the rGO nanosheets, which shows high capacitance and good redox-active properties. By applying Cd2+-ISE as a model, the electrode exhibits a Nernstian slope of 29.7 +/- 0.4 mV/decade in the activity range of 1.0 x 10-7 -7.9 x 10-4 M and the limit of detection is 6.8 x 10-8 M. Particularly, the electrode based on DAAQ-TFP@rGO exhibits a low potential drift of 1.2 +/- 0.2 mu V/h over 70 h due to the large capacitance of 2.0 mF. Moreover, the DAAQ-TFP@rGO-based Cd2+-ISE shows good reproducibility and the standard deviations of the standard potentials for single batch and batch-to-batch are 0.28 (n = 4) and 0.30 mV (n = 4), respectively. The developed SC-Cd2+-ISE is not disturbed by light or gas and no aqueous layer occurs between the sensing membrane and DAAQ-TFP@rGO layer. The DAAQ-TFP@rGO composite is highly promising for construction of calibration-free SC-ISEs.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Design of a stable solid-contact ion-selective electrode based on polyaniline nanoparticles as ion-to-electron transducer for application in process analytical technology as a real-time analyzer
    Abd El-Rahman, Mohamed K.
    Rezk, Mamdouh R.
    Mahmoud, Amr M.
    Elghobashy, Mohamed R.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 14 - 21
  • [42] Calibration-free potentiometric sensing with solid-contact ion-selective electrodes
    Rousseau, Celeste R.
    Buhlmann, Philippe
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 140
  • [43] Recent advances in nanomaterial-based solid-contact ion-selective electrodes
    Mirabootalebi, Seyed Oveis
    Liu, Yang
    ANALYST, 2024, 149 (14) : 3694 - 3710
  • [44] A solid-contact Pb2+-selective electrode based on a hydrophobic polyaniline microfiber film as the ion-to-electron transducer
    Jiang, Wenwen
    Liu, Chenchen
    Zhao, Yunyan
    Waterhouse, Geoffrey I. N.
    Zhang, Zhiming
    Yu, Liangmin
    SYNTHETIC METALS, 2019, 248 : 94 - 101
  • [45] Graphene Oxide-Poly(vinyl alcohol) Hydrogel-Coated Solid-Contact Ion-Selective Electrodes for Wearable Sweat Potassium Ion Sensing
    Liu, Siyi
    Zhong, Lijie
    Tang, Yitian
    Lai, Meixue
    Wang, Haocheng
    Bao, Yu
    Ma, Yingming
    Wang, Wei
    Niu, Li
    Gan, Shiyu
    ANALYTICAL CHEMISTRY, 2024, 96 (21) : 8594 - 8603
  • [46] Solid-contact polymeric membrane ion-selective electrodes based on electrodeposited NiCo2S4 nanosheet arrays br
    Li, Yanhong
    Li, Jinghui
    Qin, Wei
    TALANTA, 2023, 251
  • [47] Intercalation Compounds as Inner Reference Electrodes for Reproducible and Robust Solid-Contact Ion-Selective Electrodes
    Ishige, Yu
    Klink, Stefan
    Schuhmann, Wolfgang
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2016, 55 (15) : 4831 - 4835
  • [48] Potential stability of all-solid-state ion-selective electrodes using conducting polymers as ion-to-electron transducers
    Bobacka, J
    ANALYTICAL CHEMISTRY, 1999, 71 (21) : 4932 - 4937
  • [49] Solid-contact K+-selective electrode based on three-dimensional molybdenum sulfide nanoflowers as ion-to-electron transducer
    Zeng, Xianzhong
    Yu, Shunyang
    Yuan, Qun
    Qin, Wei
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 234 : 80 - 83
  • [50] Solid-Contact Ion Sensing Without Using an Ion-Selective Membrane through Classic Li-Ion Battery Materials
    Lyu, Yan
    Zhang, Yirong
    Xu, Longbin
    Zhong, Lijie
    Sun, Zhonghui
    Ma, Yingming
    Bao, Yu
    Gan, Shiyu
    Niu, Li
    ANALYTICAL CHEMISTRY, 2021, 93 (21) : 7588 - 7595