Reproducibility of deep learning based scleral spur localisation and anterior chamber angle measurements from anterior segment optical coherence tomography images

被引:18
|
作者
Liu, Peng [1 ,2 ,3 ]
Higashita, Risa [3 ,4 ]
Guo, Philip Yawen [5 ]
Okamoto, Keiichiro [4 ]
Li, Fei [6 ]
Nguyen, Anwell [7 ]
Sakata, Rei [8 ]
Duan, Lixin [1 ,2 ]
Aihara, Makoto [8 ]
Lin, Shan [7 ,9 ]
Zhang, Xiulan [6 ]
Leung, Christopher Kai-Shun [5 ]
Liu, Jiang [3 ,10 ,11 ,12 ]
机构
[1] Univ Elect Sci & Technol China, Sch Comp Sci & Engn, Chengdu, Peoples R China
[2] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Chengdu, Peoples R China
[3] Southern Univ Sci & Technol, Dept Comp Sci & Engn, Shenzhen, Peoples R China
[4] Tomey Corp, Nagoya, Aichi, Japan
[5] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Peoples R China
[6] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
[7] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA 94143 USA
[8] Univ Tokyo, Dept Ophthalmol, Tokyo, Japan
[9] Glaucoma Ctr San Francisco, San Francisco, CA USA
[10] Chinese Acad Sci, Cixi Inst Biomed Engn, Ningbo, Peoples R China
[11] Southern Univ Sci & Technol, Res Inst Trustworthy Autonomous Syst, Shenzhen, Peoples R China
[12] Southern Univ Sci & Technol, Dept Comp Sci & Engn, Guangdong Prov Key Lab Brain Inspired Intelligent, Shenzhen, Peoples R China
关键词
anterior chamber; glaucoma; CLASSIFICATION; GLAUCOMA; PREVALENCE;
D O I
10.1136/bjophthalmol-2021-319798
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To apply a deep learning model for automatic localisation of the scleral spur (SS) in anterior segment optical coherence tomography (AS-OCT) images and compare the reproducibility of anterior chamber angle (ACA) width between deep learning located SS (DLLSS) and manually plotted SS (MPSS). Methods In this multicentre, cross-sectional study, a test dataset comprising 5166 AS-OCT images from 287 eyes (116 healthy eyes with open angles and 171 eyes with primary angle-closure disease (PACD)) of 287 subjects were recruited from four ophthalmology clinics. Each eye was imaged twice by a swept-source AS-OCT (CASIA2, Tomey, Nagoya, Japan) in the same visit and one eye of each patient was randomly selected for measurements of ACA. The agreement between DLLSS and MPSS was assessed using the Euclidean distance (ED). The angle opening distance (AOD) of 750 mu m (AOD750) and trabecular-iris space area (TISA) of 750 mu m (TISA750) were calculated using the CASIA2 embedded software. The repeatability of ACA width was measured. Results The mean age was 60.8 +/- 12.3 years (range: 30-85 years) for the normal group and 63.4 +/- 10.6 years (range: 40-91 years) for the PACD group. The mean difference in ED for SS localisation between DLLSS and MPSS was 66.50 +/- 20.54 mu m and 84.78 +/- 28.33 mu m for the normal group and the PACD group, respectively. The span of 95% limits of agreement between DLLSS and MPSS was 0.064 mm for AOD750 and 0.034 mm(2) for TISA750. The respective repeatability coefficients of AOD750 and TISA750 were 0.049 mm and 0.026 mm(2) for DLLSS, and 0.058 mm and 0.030 mm(2) for MPSS. Conclusion DLLSS achieved comparable repeatability compared with MPSS for measurement of ACA.
引用
收藏
页码:802 / 808
页数:7
相关论文
共 50 条
  • [1] Reproducibility of Anterior Chamber Angle Measurements with Anterior Segment Optical Coherence Tomography
    Tan, Annelie N.
    Sauren, Loes D. C.
    de Brabander, John
    Berendschot, Tos T. J. M.
    Passos, Valeria Lima
    Webers, Carroll A. B.
    Nuijts, Rudy M. M. A.
    Beckers, Henny J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (05) : 2095 - 2099
  • [2] Reproducibility of anterior chamber angle measurements obtained with anterior segment optical coherence tomography
    Radhakrishnan, Sunita
    See, Jovina
    Smith, Scott D.
    Nolan, Winifred P.
    Ce, Zheng
    Friedman, David S.
    Huang, David
    Li, Yan
    Aung, Tin
    Chew, Paul T. K.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (08) : 3683 - 3688
  • [3] Reproducibility of Anterior Chamber Angle Measurements With Anterior Segment Coherence Tomography
    De Brabander, J.
    Tan, A. N.
    Berendschot, T. T. J. M.
    Sauren, L. D. C.
    Nekeman, D.
    Passos, V. Lima
    Webers, C. A. B.
    Beckers, H. J. M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography
    Cumba, Ricardo J.
    Radhakrishnan, Sunita
    Bell, Nicholas P.
    Nagi, Kundandeep S.
    Chuang, Alice Z.
    Lin, Shan C.
    Mankiewicz, Kimberly A.
    Feldman, Robert M.
    JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [5] Assessment of the scleral spur in anterior segment optical coherence tomography images
    Sakata, Lisandro M.
    Lavanya, Raghavan
    Friedman, David S.
    Aung, Han T.
    Seah, Steve K.
    Foster, Paul J.
    Aung, Tin
    ARCHIVES OF OPHTHALMOLOGY, 2008, 126 (02) : 181 - 185
  • [6] Repeatability and reproducibility of anterior chamber angle measurement with anterior segment optical coherence tomography
    Li, Haitao
    Leung, Christopher Kai Shun
    Cheung, Carol Yim Lui
    Wong, Lee
    Pang, Chi Pui
    Weinreb, Robert Neal
    Lam, Dennis Shun Chiu
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (11) : 1490 - 1492
  • [7] Automatic Anterior Chamber Angle Classification Using Deep Learning System and Anterior Segment Optical Coherence Tomography Images
    Li, Wanyue
    Chen, Qian
    Jiang, Chunhui
    Shi, Guohua
    Deng, Guohua
    Sun, Xinghuai
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2021, 10 (06):
  • [8] Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements
    Xiaojing Pan
    Jyotsna Maram
    Muneeswar G. Nittala
    Brian A. Francis
    Vikas Chopra
    Srinivas R. Sadda
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2020, 258 : 1475 - 1481
  • [9] Reproducibility and agreement of four anterior segment-optical coherence tomography devices for anterior chamber angle measurements
    Pan, Xiaojing
    Maram, Jyotsna
    Nittala, Muneeswar G.
    Francis, Brian A.
    Chopra, Vikas
    Sadda, Srinivas R.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 258 (07) : 1475 - 1481
  • [10] Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography
    Kim, Dong Y.
    Sung, Kyung R.
    Kang, Sung Y.
    Cho, Jung W.
    Lee, Kyoung S.
    Park, Seong B.
    Kim, Soon T.
    Kook, Michael S.
    ACTA OPHTHALMOLOGICA, 2011, 89 (05) : 435 - 441