The dosimetric error due to uncorrected tumor rotation during real-time adaptive prostate stereotactic body radiation therapy

被引:5
|
作者
Sengupta, Chandrima [1 ,9 ]
Skouboe, Simon [2 ]
Ravkilde, Thomas [3 ]
Poulsen, Per Rugaard [3 ]
Nguyen, Doan Trang
Greer, Peter B. [4 ]
Moodie, Trevor [5 ]
Hardcastle, Nicholas [6 ]
Hayden, Amy J. [5 ]
Turner, Sandra [5 ]
Siva, Shankar [6 ]
Tai, Keen-Hun [7 ]
Martin, Jarad [4 ]
Booth, Jeremy T. [8 ]
O'Brien, Ricky [1 ]
Keall, Paul J. [1 ]
机构
[1] Univ Sydney, ACRF Image X Inst, Sydney, NSW, Australia
[2] Aarhus Univ Hosp, Danish Ctr Particle Therapy, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Oncol, Aarhus, Denmark
[4] Calvary Mater Newcastle, Dept Radiat Oncol, Waratah, NSW, Australia
[5] Crown Princess Mary Canc Ctr, Sydney, NSW, Australia
[6] Peter MacCallum Canc Ctr, Melbourne, Vic, Australia
[7] Univ Melbourne, Sir Peter MacCallum Dept Oncol, Melbourne, Vic, Australia
[8] Royal North Shore Hosp, Northern Sydney Canc Ctr, Sydney, NSW, Australia
[9] Univ Sydney, ACRF Image X Inst, Sydney, NSW 2015, Australia
关键词
motion management; motion-induced dose error; tumor motion; INTENSITY-MODULATED RADIOTHERAPY; LOCALIZATION; ADAPTATION; SYSTEM; IMPACT; ONLINE; IMAGER; VOLUME; ROLL;
D O I
10.1002/mp.16094
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundDuring prostate stereotactic body radiation therapy (SBRT), prostate tumor translational motion may deteriorate the planned dose distribution. Most of the major advances in motion management to date have focused on correcting this one aspect of the tumor motion, translation. However, large prostate rotation up to 30 degrees has been measured. As the technological innovation evolves toward delivering increasingly precise radiotherapy, it is important to quantify the clinical benefit of translational and rotational motion correction over translational motion correction alone. PurposeThe purpose of this work was to quantify the dosimetric impact of intrafractional dynamic rotation of the prostate measured with a six degrees-of-freedom tumor motion monitoring technology. MethodsThe delivered dose was reconstructed including (a) translational and rotational motion and (b) only translational motion of the tumor for 32 prostate cancer patients recruited on a 5-fraction prostate SBRT clinical trial. Patients on the trial received 7.25 Gy in a treatment fraction. A 5 mm clinical target volume (CTV) to planning target volume (PTV) margin was applied in all directions except the posterior direction where a 3 mm expansion was used. Prostate intrafractional translational motion was managed using a gating strategy, and any translation above the gating threshold was corrected by applying an equivalent couch shift. The residual translational motion is denoted as Tres$T_{res}$. Prostate intrafractional rotational motion Runcorr$R_{uncorr}$ was recorded but not corrected. The dose differences from the planned dose due to Tres$T_{res}$ + Runcorr$R_{uncorr}$, Delta D(Tres$T_{res}$ + Runcorr$R_{uncorr}$) and due to Tres$T_{res}$ alone, Delta D(Tres$T_{res}$), were then determined for CTV D98, PTV D95, bladder V6Gy, and rectum V6Gy. The residual dose error due to uncorrected rotation, Runcorr$R_{uncorr}$ was then quantified: Delta DResidual$\Delta D_{Residual}$ = Delta D(Tres$T_{res}$ + Runcorr$R_{uncorr}$) - Delta D(Tres${T}_{\textit{res}}$). ResultsFractional data analysis shows that the dose differences from the plan (both Delta D(Tres$T_{res}$ + Runcorr$R_{uncorr}$) and Delta D(Tres$T_{res}$)) for CTV D98 was less than 5% in all treatment fractions. Delta D(Tres$T_{res}$ + Runcorr$R_{uncorr}$) was larger than 5% in one fraction for PTV D95, in one fraction for bladder V6Gy, and in five fractions for rectum V6Gy. Uncorrected rotation, Runcorr$R_{uncorr}$ induced residual dose error, Delta DResidual$\Delta D_{Residual}$, resulted in less dose to CTV and PTV in 43% and 59% treatment fractions, respectively, and more dose to bladder and rectum in 51% and 53% treatment fractions, respectively. The cumulative dose over five fractions, n-ary sumation D(Tres$T_{res}$ + Runcorr$R_{uncorr}$) and n-ary sumation D(Tres$T_{res}$), was always within 5% of the planned dose for all four structures for every patient. ConclusionsThe dosimetric impact of tumor rotation on a large prostate cancer patient cohort was quantified in this study. These results suggest that the standard 3-5 mm CTV-PTV margin was sufficient to account for the intrafraction prostate rotation observed for this cohort of patients, provided an appropriate gating threshold was applied to correct for translational motion. Residual dose errors due to uncorrected prostate rotation were small in magnitude, which may be corrected using different treatment adaptation strategies to further improve the dosimetric accuracy.
引用
收藏
页码:20 / 29
页数:10
相关论文
共 50 条
  • [41] Evaluation of Rectal Interfractional Dosimetric Variation using Balloon Immobilization during Volumetric Modulated Arc Therapy for Stereotactic Body Radiation Therapy of the Prostate
    Gan, G. N.
    Diot, Q.
    Westerly, D.
    Timmerman, R. D.
    Miften, M.
    Raben, D.
    Stuhr, K.
    Dzingle, W.
    Kavanagh, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S793 - S794
  • [42] Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
    Konstantina Karava
    Stefanie Ehrbar
    Oliver Riesterer
    Johannes Roesch
    Stefan Glatz
    Stephan Klöck
    Matthias Guckenberger
    Stephanie Tanadini-Lang
    Radiation Oncology, 12
  • [43] Potential dosimetric benefits of adaptive tumor tracking over the internal target volume concept for stereotactic body radiation therapy of pancreatic cancer
    Karava, Konstantina
    Ehrbar, Stefanie
    Riesterer, Oliver
    Roesch, Johannes
    Glatz, Stefan
    Klock, Stephan
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    RADIATION ONCOLOGY, 2017, 12
  • [44] A Dosimetric Comparison of Stereotactic Body Radiation Therapy Delivery Techniques for Lung Cancer: Adaptive Versus Conventional
    Ding, C.
    Godley, A.
    Westover, K.
    Timmerman, R.
    Park, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [45] Relative motion of implanted prostate fiducials during stereotactic body radiation therapy
    Edwards, M.
    Anderson, J.
    Boike, T.
    Li, T.
    Timmerman, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S376 - S376
  • [46] Dosimetric evaluation of simultaneous integrated boost during stereotactic body radiation therapy for pancreatic cancer
    Yang, Wensha
    Reznik, Robert
    Fraass, Benedick A.
    Nissen, Nicholas
    Hendifar, Andrew
    Wachsman, Ashley
    Sandler, Howard
    Tuli, Richard
    MEDICAL DOSIMETRY, 2015, 40 (01) : 47 - 52
  • [47] Real-Time Assessment of Dosimetric Variations in Head-and-Neck Radiation Therapy
    Qi, X.
    Neylon, J.
    Santhanam, A.
    Min, Y.
    Sheng, K.
    Low, D.
    Lee, S.
    Steinberg, M.
    Kupelian, P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S135 - S135
  • [48] Lung stereotactic body radiotherapy with electromagnetic transponders for real-time tumor tracking
    Jaccard, Maud
    Jaccard, M.
    Champion, A.
    Dubouloz, A.
    Plojoux, J.
    Soccal, P.
    Miralbell, R.
    Dipasquale, G.
    Caparrotti, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2019, 195 (12) : 1126 - 1126
  • [49] Evaluation of Reproducibility and Stability of Deep Inspiration Breath-Hold in Lung Stereotactic Body Radiation Therapy Using a Real-Time Tumor-Tracking Radiation Therapy System
    Kawazoe, Y.
    Shiinoki, T.
    Fujimoto, K.
    Yuasa, Y.
    Mukaidani, W.
    Tanaka, H.
    MEDICAL PHYSICS, 2024, 51 (09) : 6641 - 6641
  • [50] Target margin design for real-time lung tumor tracking stereotactic body radiation therapy using CyberKnife Xsight Lung Tracking System
    Zhi-Yong Yang
    Yu Chang
    Hong-Yuan Liu
    Gang Liu
    Qin Li
    Scientific Reports, 7