Investigation of the Interactions between Refrigerant, Flowsheet, and Compressor in Residential Heat Pumps

被引:4
|
作者
Hoeges, Christoph [1 ]
Roskosch, Dennis [2 ]
Brach, Jona [1 ]
Vering, Christian [1 ]
Venzik, Valerius [1 ]
Mueller, Dirk [1 ]
机构
[1] Rhein Westfal TH Aachen, EON Energy Res Ctr, Inst Energy Efficient Bldg & Indoor Climate, D-52074 Aachen, Germany
[2] Swiss Fed Inst Technol, Energy & Proc Syst Engn, CH-8092 Zurich, Switzerland
关键词
EN; 14825; internal heat exchangers; loss-based compressor model; vapor injection; zeotropic mixtures; LOW-GWP REFRIGERANTS; NATURAL REFRIGERANTS; THERMODYNAMIC ANALYSIS; PERFORMANCE EVALUATION; TEMPERATURE GLIDE; SYSTEM; INJECTION; MIXTURES; OPTIONS; PHASE;
D O I
10.1002/ente.202201295
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The refrigerant used in heat pumps significantly influences the overall system performance. However, selecting a proper refrigerant is no trivial matter due to the heat pumps' sensitivity to the selected flowsheet, components, and operating conditions. Herein, a holistic approach is used that covers all these interdependencies simultaneously considering the flowsheet, fluid-dependent compressor efficiencies, and the operating point. Six low global warming potential (GWP<150) refrigerants are investigated, which include pure fluids, azeotropic mixtures, and zeotropic mixtures from different substance groups. For four flowsheets, the seasonal coefficient of performance (SCOP) by EN 14825 is calculated and serves as the assessment metric. The case study is based on typical conditions of residential heat pumps. The results show that the SCOPs substantially differ depending on the refrigerant and the flowsheet (reaching from 3.8 to 4.6). Differences in the performance of refrigerants for an equal flowsheet are mainly driven by compressor efficiency. However, these differences can be overcome by adjusting the flowsheet. In particular, when an internal heat exchanger is added, the refrigerant ranking is substantially changed. It is shown that R436A, which is inferior to R290 for the basic cycle, benefits more from an internal heat exchanger and reaches a competitive SCOP than R290.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] To The Question of the Use of Working Substances in Vapor Compressor Heat Pumps
    Rachkovsky, N. O.
    Tatarenko, Yu. V.
    OIL AND GAS ENGINEERING (OGE-2019), 2019, 2141
  • [42] PARAMETERS OF PISTON COMPRESSOR OF HEAT PUMPS IN PARTIAL OPERATION MODES
    Barskii, I. A.
    Antipov, Yu. A.
    Shatalov, I. K.
    Terekhov, D. V.
    CHEMICAL AND PETROLEUM ENGINEERING, 2011, 47 (1-2) : 53 - 58
  • [43] Compressor-driven metal-hydride heat pumps
    Kim, KJ
    Feldman, KT
    Lloyd, G
    Razani, A
    APPLIED THERMAL ENGINEERING, 1997, 17 (06) : 551 - 560
  • [44] THERMAL IMPACT OF RESIDENTIAL GROUNDWATER HEAT-PUMPS
    WARNER, DL
    ALGAN, U
    GROUND WATER, 1984, 22 (01) : 6 - 12
  • [45] Patterns in spatial diffusion of residential heat pumps in Switzerland
    Zhang, Haodong
    Zielonka, Nik
    Trutnevyte, Evelina
    RENEWABLE ENERGY, 2024, 223
  • [46] Residential heat pumps in the future Danish energy system
    Petrovic, Stefan N.
    Karlsson, Kenneth B.
    ENERGY, 2016, 114 : 787 - 797
  • [47] ENERGY EFFICIENCIES OF HEAT-PUMPS IN RESIDENTIAL BUILDINGS
    INGERSOLL, JG
    ARASTEH, DK
    ENERGY AND BUILDINGS, 1983, 5 (04) : 253 - 262
  • [48] Solar assisted heat pumps for residential use.
    Bessler, W.F.
    Hwang, B.C.
    1980, 22 (9 , Sep. 1980, p.59-63.):
  • [49] Experimental Investigation of a Rolling Piston Compressor Operated with a Zeotropic Refrigerant Mixture
    Cop, Melanie
    Thomas, Christiane
    Hesse, Ullrich
    6TH IIR CONFERENCE ON THERMOPHYSICAL PROPERTIES AND TRANSFER PROCESSES OF REFRIGERANTS (TPTPR2021), 2021, : 260 - 267
  • [50] An economic and technical case for a compressor/expander unit for heat pumps
    Henderson, PC
    Hewitt, NJ
    Mongey, B
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2000, 24 (09) : 831 - 842