Pseudo-discordance mimicking low-flow low-gradient aortic stenosis in transcatheter aortic valve replacement patients with severe symptomatic aortic stenosis

被引:1
|
作者
Kuperstein, Rafael [1 ,2 ]
Michlin, Michael [1 ,2 ]
Barbash, Israel [1 ,2 ]
Mazin, Israel [1 ,2 ]
Brodov, Yafim [1 ,2 ,3 ]
Fefer, Paul [1 ,2 ]
Segev, Amit [1 ,2 ]
Guetta, Victor [1 ,2 ]
Maor, Elad [1 ,2 ]
Goiten, Orly [2 ,3 ]
Arad, Michael [1 ,2 ]
Feinberg, Micha S. [1 ,2 ]
Schwammenthal, Ehud [1 ,2 ]
机构
[1] Sheba Med Ctr, Leviev Heart Ctr, Ramat Gan, Israel
[2] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
[3] Sheba Med Ctr, Dept Diagnost Imaging, Ramat Gan, Israel
关键词
aortic stenosis; echocardiography; aortic valve; valvular disease; calcium; EUROPEAN ASSOCIATION; AREA; CALCIFICATION; GUIDELINES; SOCIETY;
D O I
10.5603/CJ.a2021.0106
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: While the combination of a small aortic valve area (AVA) and low mean gradient is frequently labeled 'low-flow low-gradient aortic stenosis (AS)', there are two potential causes for this finding: underestimation of mean gradient and underestimation of AVA. Methods: In order to investigate the prevalence and causes of discordant echocardiographic findings in symptomatic patients with AS and normal left ventricular (LV) function, we evaluated 72 symptomatic patients with AS and normal LV function by comparing Doppler, invasive, computed tomography (CT) LV outflow tract (LVOT) area, and calcium score (CaSc). Results: Thirty-six patients had discordant echocardiographic findings (mean gradient < 40 mmHg, AVA <= 1 cm(2)). Of those, 19 had discordant invasive measurements (true discordant [TD]) and 17 concordant (false discordant [FD]): In 12 of the FD the mean gradient was > 30 mmHg; technical pitfalls were found in 10 patients (no reliable right parasternal Doppler in 6). LVOT area by echocardiography or CT could not differentiate between concordants and discordants nor between TD and FD (p = NS). CaSc was similar in concordants and FD (p = 0.3), and it was higher in true concordants than in TD (p = 0.005). CaSc positive predictive value for the correct diagnosis of severe AS was 95% for concordants and 93% for discordants. Conclusions: Discordant echocardiographic findings are commonly found in patients with symptomatic AS. Underestimation of the true mean gradient due to technical difficulties is an important cause of these discrepant findings. LVOT area by echocardiography or CT cannot differentiate between TD and FD. In the absence of a reliable and compete multi-window Doppler evaluation, patients should undergo CaSc assessment.
引用
收藏
页码:422 / 430
页数:9
相关论文
共 50 条
  • [1] Pseudo-discordance mimicking low-flow low-gradient aortic stenosis in transcatheter aortic valve replacement patients with severe symptomatic aortic stenosis
    Kuperstein, Rafael
    Michlin, Michael
    Barbash, Israel
    Mazin, Israel
    Brodov, Yafim
    Fefer, Paul
    Segev, Amit
    Guetta, Victor
    Maor, Elad
    Goiten, Orly
    Arad, Michael
    Feinberg, Micha S.
    Schwammenthal, Ehud
    [J]. CARDIOLOGY JOURNAL, 2021,
  • [2] Pseudo-discordance mimicking low-flow low-gradient AS in TAVR patients with severe symptomatic aortic stenosis
    Kuperstein, R.
    Michlin, M.
    Barbash, I.
    Mazin, I.
    Brodov, Y.
    Segev, A.
    Fefer, P.
    Arad, M.
    Ben Zekry, S.
    Schwammenthal, E.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 525 - 525
  • [3] Transcatheter Aortic Valve Replacement (TAVR) in Patients with Paradoxical Low-Flow Low-Gradient Aortic Stenosis
    Thakker, Prashanth
    Husaini, Mustafa
    Thangam, Manoj
    Lindman, Brian
    Maniar, Hersh
    Quader, Nishath
    Melby, Spencer
    Sintek, Marc
    Kachroo, Puja
    Lasala, John
    Zajarias, Alan
    [J]. STRUCTURAL HEART-THE JOURNAL OF THE HEART TEAM, 2020, 4 (04): : 312 - 319
  • [4] Transcatheter aortic valve replacement outcomes in patients with low-flow very low-gradient aortic stenosis
    Ueyama, Hiroki A.
    Chopra, Lakshay
    Dalsania, Ankur
    Prandi, Francesca Romana
    Sharma, Samin K.
    Kini, Annapoorna
    Lerakis, Stamatios
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (02) : 267 - 277
  • [5] Transcatheter Aortic Valve Implantation in Patients With Low-Flow, Low-Gradient Aortic Stenosis
    Lauten, Alexander
    Zahn, Ralf
    Horack, Martin
    Sievert, Horst
    Linke, Axel
    Ferrari, Markus
    Harnath, Axel
    Grube, Eberhard
    Gerckens, Ulrich
    Kuck, Karl-Heinz
    Sack, Stefan
    Senges, Jochen
    Figulla, Hans R.
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 552 - 559
  • [6] Transcatheter Aortic Valve Implantation to Low-Flow Low-Gradient Aortic Stenosis
    Higuchi, Ryosuke
    Tobaru, Tetsuya
    Mahara, Keitaro
    Naito, Kazuhiro
    Shimizu, Jun
    Takamisawa, Itaru
    Iguchi, Nobuo
    Takanashi, Shuichiro
    Toshikawa, Tsutomu
    Takayama, Morimasa
    [J]. JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : S166 - S167
  • [7] Calcification Characteristics of Low-Flow Low-Gradient Severe Aortic Stenosis in Patients Undergoing Transcatheter Aortic Valve Replacement
    Staehli, Barbara E.
    Nguyen-Kim, Thi Dan Linh
    Gebhard, Catherine
    Frauenfelder, Thomas
    Tanner, Felix C.
    Nietlispach, Fabian
    Maisano, Francesco
    Falk, Volkmar
    Luescher, Thomas F.
    Maier, Willibald
    Binder, Ronald K.
    [J]. CARDIOLOGY RESEARCH AND PRACTICE, 2015, 2015
  • [8] UTILIZATION OF DOBUTAMINE STRESS STUDIES IN PATIENTS WITH SYMPTOMATIC, SEVERE LOW-FLOW/LOW-GRADIENT AORTIC STENOSIS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Chowdhury, Mohsin
    Trejo, Maria
    Lombo, Bernardo
    Forrest, John
    Lin, Ben
    Sugeng, Lissa
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2018, 71 (11) : 1326 - 1326
  • [9] Risk of mortality following transcatheter aortic valve replacement for low-flow low-gradient aortic stenosis
    Wilde, Nihal
    Sugiura, Atsushi
    Sedaghat, Alexander
    Becher, Marc Ulrich
    Kelm, Malte
    Baldus, Stephan
    Nickenig, Georg
    Veulemans, Verena
    Tiyerili, Vedat
    [J]. CLINICAL RESEARCH IN CARDIOLOGY, 2021, 110 (03) : 391 - 398
  • [10] Transcatheter Aortic Valve Implantation in Patients With Paradoxical Low-Flow, Low-Gradient Aortic Stenosis
    Rodriguez-Gabella, Tania
    Nombela-Franco, Luis
    Auffret, Vincent
    Asmarats, Lluis
    Islas, Fabian
    Maes, Frederic
    Ferreira-Neto, Alfredo Nunes
    Paradis, Jean-Michel
    Dumont, Eric
    Cote, Melanie
    Jimenez-Quevedo, Pilar
    Macaya, Carlos
    Pibarot, Philippe
    Rodes-Cabau, Josep
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (04): : 625 - 632