Transcatheter Aortic Valve Replacement (TAVR) in Patients with Paradoxical Low-Flow Low-Gradient Aortic Stenosis

被引:0
|
作者
Thakker, Prashanth [1 ]
Husaini, Mustafa [1 ]
Thangam, Manoj [1 ]
Lindman, Brian [2 ]
Maniar, Hersh [3 ]
Quader, Nishath [1 ]
Melby, Spencer [3 ]
Sintek, Marc [1 ]
Kachroo, Puja [3 ]
Lasala, John [1 ]
Zajarias, Alan [1 ]
机构
[1] Washington Univ, Sch Med, Dept Med, Div Cardiovasc Med, 660 S Euclid Ave,Campus Box 8086, St Louis, MO 63110 USA
[2] Vanderbilt Univ, Med Ctr, Dept Med, Div Cardiovasc Med, 221 Kirkland Hall, Nashville, TN 37235 USA
[3] Washington Univ, Sch Med, Dept Surg, Div Cardiothorac Surg, 660 S Euclid Ave,Campus Box 8086, St Louis, MO 63110 USA
来源
关键词
Transcatheter aortic valve replacement; aortic stenosis; paradoxical low flow low gradient;
D O I
10.1080/24748706.2020.1764155
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Aortic valve replacement is recommended in symptomatic patients with severe aortic stenosis (AS) or asymptomatic with reduced left ventricular ejection fraction (LVEF). The treatment algorithm of patients with paradoxical low-flow (pLF-LG) AS is not well defined. The purpose of this study is to examine the efficacy and outcomes of TAVR in patients with pLF-LG AS at our institution. Methods: From 2008 to 2017, we retrospectively analyzed patients who underwent TAVR with an LVEF > 50% and stratified into 4 groups based on gradient and stroke volume index. The groups were normal flow, high gradient (NFHG), normal flow, low gradient (NFLG), low flow, high gradient (LFHG), and paradoxical low flow, low gradient (pLF-LG). Baseline, procedural characteristics, post-procedure, 30-day, and 12-month endpoints were obtained. Our primary endpoints included all-cause mortality and major adverse cardiac and cerebrovascular events (MACCE) at post-procedure, 30 days, and 1 year. Results: Groups were NF-HG (n = 145), NF-LG (n = 81), LF-HG (n = 97), and pLF-LG (n = 75). There was an increased prevalence of pacemakers in the pLF-LG group (p = 0.01) and a significant difference in the prevalence of atrial fibrillation (AF) (p = 0.01). No difference in post-procedure, 30-day, and 12-month all-cause mortality and MACCE was noted. All patients demonstrated symptomatic improvement as measured by New York Heart Association (NYHA) class at 30 days and 12 months (p < 0.0001) Conclusion: When compared to patients with normal flow and high gradients, patients with pLF-LG treated with TAVR had similar procedural complications and 30-day and 1-year mortality with improvement in symptom profile. Once identified as symptomatic, patients with pLF-LG should undergo valve replacement.
引用
收藏
页码:312 / 319
页数:8
相关论文
共 50 条
  • [1] Transcatheter Aortic Valve Implantation in Patients With Paradoxical Low-Flow, Low-Gradient Aortic Stenosis
    Rodriguez-Gabella, Tania
    Nombela-Franco, Luis
    Auffret, Vincent
    Asmarats, Lluis
    Islas, Fabian
    Maes, Frederic
    Ferreira-Neto, Alfredo Nunes
    Paradis, Jean-Michel
    Dumont, Eric
    Cote, Melanie
    Jimenez-Quevedo, Pilar
    Macaya, Carlos
    Pibarot, Philippe
    Rodes-Cabau, Josep
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 122 (04): : 625 - 632
  • [2] Transcatheter aortic valve implantation for paradoxical low-flow low-gradient aortic stenosis patients
    Debry, Nicolas
    Sudre, Arnaud
    Amr, Gilles
    Delhaye, Cedric
    Schurtz, Guillaume
    Montaigne, David
    Koussa, Mohamad
    Modine, Thomas
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2016, 87 (04) : 797 - 804
  • [3] Prognosis of paradoxical low-flow low-gradient aortic stenosis after transcatheter aortic valve replacement
    Saito, Yukihiro
    Lewis, Erik E.
    Raval, Amish
    Gimelli, Giorgio
    Jacobson, Kurt
    Osaki, Satoru
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2021, 22 (06) : 486 - 491
  • [4] Transcatheter aortic valve replacement in patients with paradoxical low-flow, low-gradient aortic stenosis: Incidence and predictors of treatment futility
    Freitas-Ferraz, Afonso B.
    Nombela-Franco, Luis
    Urenac, Marina
    Maes, Frederic
    Veiga, Gabriela
    Ribeiro, Henrique
    Vilalta, Victoria
    Silva, Iria
    Cheema, Asim N.
    Islas, Fabian
    Fischer, Quentin
    Fradejas-Sastre, Victor
    Egypto Rosa, Vitor Emer
    Fernandez-Nofrerias, Eduard
    Moris, Cesar
    Junquera, Lucia
    Mohammadi, Siamak
    Pibarot, Philippe
    Rodes-Cabau, Josep
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 316 : 57 - 63
  • [5] Transcatheter aortic valve replacement outcomes in patients with low-flow very low-gradient aortic stenosis
    Ueyama, Hiroki A.
    Chopra, Lakshay
    Dalsania, Ankur
    Prandi, Francesca Romana
    Sharma, Samin K.
    Kini, Annapoorna
    Lerakis, Stamatios
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2024, 25 (02) : 267 - 277
  • [6] Transcatheter Aortic Valve Implantation in Patients With Low-Flow, Low-Gradient Aortic Stenosis
    Lauten, Alexander
    Zahn, Ralf
    Horack, Martin
    Sievert, Horst
    Linke, Axel
    Ferrari, Markus
    Harnath, Axel
    Grube, Eberhard
    Gerckens, Ulrich
    Kuck, Karl-Heinz
    Sack, Stefan
    Senges, Jochen
    Figulla, Hans R.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2012, 5 (05) : 552 - 559
  • [7] Transcatheter Aortic Valve Implantation to Low-Flow Low-Gradient Aortic Stenosis
    Higuchi, Ryosuke
    Tobaru, Tetsuya
    Mahara, Keitaro
    Naito, Kazuhiro
    Shimizu, Jun
    Takamisawa, Itaru
    Iguchi, Nobuo
    Takanashi, Shuichiro
    Toshikawa, Tsutomu
    Takayama, Morimasa
    JOURNAL OF CARDIAC FAILURE, 2015, 21 (10) : S166 - S167
  • [8] Outcome of isolated aortic valve replacement in patients with classic and paradoxical low-flow, low-gradient aortic stenosis
    Lopez-Marco, Ana
    Miller, Harriet
    Kumar, Pankaj
    Ashraf, Saeed
    Zaidi, Afzal
    Bhatti, Farah
    Ionescu, Adrian
    Youhana, Aprim
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 154 (02): : 435 - 442
  • [9] True-severe stenosis in paradoxical low-flow low-gradient aortic stenosis: outcomes after transcatheter aortic valve replacement
    Okuno, Taishi
    Corpataux, Noe
    Spano, Giancarlo
    Grani, Christoph
    Heg, Dik
    Brugger, Nicolas
    Lanz, Jonas
    Praz, Fabien
    Stortecky, Stefan
    Siontis, George C. M.
    Windecker, Stephan
    Pilgrim, Thomas
    EUROPEAN HEART JOURNAL-QUALITY OF CARE AND CLINICAL OUTCOMES, 2021, 7 (04) : 366 - 377
  • [10] Predictors of Flow Improvement Following Transcatheter Aortic Valve Replacement in Patients with Low-Flow Low-Gradient Aortic Stenosis
    Besir, Besir
    Majeed-Saidan, Maryam Muhammad Ali
    Rajendran, Judah
    Lomaia, Tamari
    Ramu, Shivabalan Kathavarayan
    Iskandar, Odette
    Yun, James
    Harb, Serge
    Miyasaka, Rhonda
    Reed, Grant
    Puri, Rishi
    Krishnaswamy, Amar
    Kapadia, Samir
    CIRCULATION, 2024, 150