Photochemical Tissue Bonding of Amnion Allograft Membranes for Peripheral Nerve Repair: A Biomechanical Analysis

被引:0
|
作者
King, Nicholas C. [1 ]
McGuire, Kalyn R. [1 ]
Bejar-Chapa, Maria [1 ]
Hoftiezer, Yannick A. J. [1 ]
Randolph, Mark A. [1 ]
Winograd, Jonathan M. [1 ,2 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Div Plast & Reconstruct Surg, Peripheral Nerve Res Lab, Boston, MA USA
[2] Massachusetts Gen Hosp, Div Plast & Reconstruct Surg, Peripheral Nerve Res Lab, 15 Parkman St,WACC Suite 435, Boston, MA 02114 USA
关键词
nerve; photochemical tissue bonding; amnion; allograft; neurorrhaphy; ULNAR;
D O I
10.1055/s-0043-1772670
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Photochemical tissue bonding (PTB) is a technique for peripheral nerve repair in which a collagenous membrane is bonded around approximated nerve ends. Studies using PTB with cryopreserved human amnion have shown promising results in a rat sciatic nerve transection model including a more rapid and complete return of function, larger axon size, and thicker myelination than suture repair. Commercial collagen membranes, such as dehydrated amnion allograft, are readily available, offer ease of storage, and have no risk of disease transmission or tissue rejection. However, the biomechanical properties of these membranes using PTB are currently unknown in comparison to PTB of cryopreserved human amnion and suture neurorrhaphy. Methods Rat sciatic nerves (n = 10 per group) were transected and repaired using either suture neurorrhaphy or PTB with one of the following membranes: cryopreserved human amnion, monolayer human amnion allograft (crosslinked and noncrosslinked), trilayer human amnion/chorion allograft (crosslinked and noncrosslinked), or swine submucosa. Repaired nerves were subjected to mechanical testing. Results During ultimate stress testing, the repair groups that withstood the greatest strain increases were suture neurorrhaphy (69 +/- 14%), PTB with crosslinked trilayer amnion (52 +/- 10%), and PTB with cryopreserved human amnion (46 +/- 20%), although the differences between these groups were not statistically significant. Neurorrhaphy repairs had a maximum load (0.98 +/- 0.30 N) significantly greater than all other repair groups except for noncrosslinked trilayer amnion (0.51 +/- 0.27 N). During fatigue testing, all samples repaired with suture, or PTBs with either crosslinked or noncrosslinked trilayer amnion were able to withstand strain increases of at least 50%. Conclusion PTB repairs with commercial noncrosslinked amnion allograft membranes can withstand physiological strain and have comparable performance to repairs with human amnion, which has demonstrated efficacy in vivo. These results indicate the need for further testing of these membranes using in vivo animal model repairs.
引用
收藏
页码:232 / 238
页数:7
相关论文
共 50 条
  • [11] LASER-ACTIVATED EXCISIONAL WOUND REPAIR WITH PHOTOCHEMICAL TISSUE BONDING
    Tsao, Sandy
    Yao, Min
    Henry, Frank
    Tsao, Hensin
    Redmond, Robert
    Kochevar, Irene
    LASERS IN SURGERY AND MEDICINE, 2009, : 108 - 108
  • [12] An update–tissue engineered nerve grafts for the repair of peripheral nerve injuries
    Nitesh P.Patel
    Kristopher A.Lyon
    Jason H.Huang
    Neural Regeneration Research, 2018, 13 (05) : 764 - 774
  • [13] A tissue-engineered conduit for peripheral nerve repair
    Hadlock, T
    Elisseeff, J
    Langer, R
    Vacanti, J
    Cheney, M
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 1998, 124 (10) : 1081 - 1086
  • [14] Biomechanical microenvironment in peripheral nerve regeneration: from pathophysiological understanding to tissue
    Kong, Lingchi
    Gao, Xin
    Qian, Yun
    Sun, Wei
    You, Zhengwei
    Fan, Cunyi
    THERANOSTICS, 2022, 12 (11): : 4993 - 5014
  • [16] Peripheral nerve allograft prepared by an acellular, hypotonic tissue engineering method
    Sun, Huizhe
    Dai, Wenying
    Wang, Jie
    Tong, Xiaojie
    Tian, Wei
    Xu, Jun
    NEURAL REGENERATION RESEARCH, 2010, 5 (08) : 630 - 634
  • [17] An update-tissue engineered nerve grafts for the repair of peripheral nerve injuries
    Patel, Nitesh P.
    Lyon, Kristopher A.
    Huang, Jason H.
    NEURAL REGENERATION RESEARCH, 2018, 13 (05) : 764 - 774
  • [18] SIMULTANEOUS REPAIR OF PERIPHERAL NERVE AND SOFT TISSUE DEFECTS IN THE FOREARM
    ALLBRITTEN, FF
    ANNALS OF SURGERY, 1947, 125 (04) : 447 - 451
  • [19] Nerve autografts and tissue-engineered materials for the repair of peripheral nerve injuries: a 5-year bibliometric analysis
    Gao, Yuan
    Wang, Yu-ling
    Kong, Dan
    Qu, Bo
    Su, Xiao-jing
    Li, Huan
    Pi, Hong-ying
    NEURAL REGENERATION RESEARCH, 2015, 10 (06) : 1003 - 1008
  • [20] Nerve autografts and tissue-engineered materials for the repair of peripheral nerve injuries: a 5-year bibliometric analysis
    Yuan Gao
    Yu-ling Wang
    Dan Kong
    Bo Qu
    Xiao-jing Su
    Huan Li
    Hong-ying Pi
    Neural Regeneration Research, 2015, 10 (06) : 1003 - 1008