Seismic performance assessment of deteriorated reinforced concrete columns using a new plastic-hinge element

被引:0
|
作者
Kim, Tae-Hoon [1 ]
Jung, Hosung [2 ]
机构
[1] Korea Railroad Res Inst, Adv Railroad Civil Engn Div, 176 Cheoldobangmulgwan Ro, Uiwang Si 16105, Gyeonggi Do, South Korea
[2] Korea Railroad Res Inst, Smart Elect Signaling Div, 176 Cheoldobangmulgwan Ro, Uiwang Si 16105, Gyeonggi Do, South Korea
来源
COMPUTERS AND CONCRETE | 2023年 / 32卷 / 02期
关键词
column; deteriorated; plastic-hinge element; reinforced concrete; seismic performance; BRIDGE PIERS; BEHAVIOR; CORROSION; DUCTILITY; STRENGTH; CAPACITY; MODEL;
D O I
10.12989/cac.2023.32.2.139
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The purpose of this paper is to numerically assess the seismic performance of deteriorated reinforced concrete columns using a new plastic-hinge element. Developing a three dimensional (3D) nonlinear model can be difficult and computationally complex, and there can be problems applying it in the field. Thus, to solve these problems, a plastic-hinge element that could considers the shear deformation of deteriorated reinforced concrete columns was proposed. The developed element was based on the Timoshenko beam model and used two nodes with six degrees of freedom and a zero-length element. Moreover, the developed model could consider the combined effects of corrosion, as demonstrated by the reduced reinforcement area and the loss of bond. Consequently, the numerical procedures developed for evaluating the seismic performance of deteriorated columns were validated by comparing the verification results.
引用
收藏
页码:139 / 148
页数:10
相关论文
共 50 条
  • [1] Seismic Performance of Reinforced Concrete Columns with Lap Splices in Plastic Hinge Region
    Kim, Chul-Goo
    Park, Hong-Gun
    Eom, Tae-Sung
    ACI STRUCTURAL JOURNAL, 2018, 115 (01) : 235 - 245
  • [2] Assessment of plastic hinge length in reinforced concrete columns
    Pham, Phu-Anh-Huy
    Hung, Chung-Chan
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2023,
  • [3] A novel formula for plastic hinge length of reinforced concrete columns in seismic regions
    Wei, Wang
    Shao, Changjiang
    Huang, Hui
    Zhuang, Weilin
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2024, 20 (10) : 1484 - 1499
  • [4] Plastic hinge length of reinforced concrete columns
    Bae, Sungjin
    Bayrak, Oguzhan
    ACI STRUCTURAL JOURNAL, 2008, 105 (03) : 290 - 300
  • [5] Experimental and numerical investigations of the seismic performance of columns with fiber-reinforced concrete in the plastic hinge region
    Liang, Xingwen
    Xing, Pengtao
    Xu, Jie
    ADVANCES IN STRUCTURAL ENGINEERING, 2016, 19 (09) : 1484 - 1499
  • [6] Novel Plastic Hinge Element for Seismic Performance Assessment of RC Bridge Columns with Lap Splices
    Tae-Hoon Kim
    Ki-Young Eum
    Hyun Mock Shin
    International Journal of Concrete Structures and Materials, 17
  • [7] Novel Plastic Hinge Element for Seismic Performance Assessment of RC Bridge Columns with Lap Splices
    Kim, Tae-Hoon
    Eum, Ki-Young
    Shin, Hyun Mock
    INTERNATIONAL JOURNAL OF CONCRETE STRUCTURES AND MATERIALS, 2023, 17 (01)
  • [8] Plastic Hinge Length of Reinforced Concrete Columns Discussion
    Subramanian, N.
    Elmenshawi, Abdelsamie
    ACI STRUCTURAL JOURNAL, 2009, 106 (02) : 233 - 237
  • [9] Plastic hinge length of circular reinforced concrete columns
    Ou, Yu-Chen
    Kurniawan, Raditya Andy
    Kurniawan, Dimas Pramudya
    Nguyen Dang Nguyen
    COMPUTERS AND CONCRETE, 2012, 10 (06): : 663 - 681
  • [10] Seismic performance assessment of lightly reinforced concrete columns
    Wibowo, A.
    Wilson, J. L.
    Fardipour, M.
    Lam, N. T. K.
    Rodsin, K.
    Lukkunaprasit, P.
    Gad, E. F.
    INCORPORATING SUSTAINABLE PRACTICE IN MECHANICS OF STRUCTURES AND MATERIALS, 2011, : 341 - 346