Conduction system pacing in prosthetic heart valves
被引:2
|
作者:
Shah, Kuldeep
论文数: 0引用数: 0
h-index: 0
机构:
Oakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Shah, Kuldeep
[1
]
Williamson, Brian D.
论文数: 0引用数: 0
h-index: 0
机构:
Oakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Williamson, Brian D.
[1
]
Kutinsky, Ilana
论文数: 0引用数: 0
h-index: 0
机构:
Oakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Kutinsky, Ilana
[1
]
Bhardwaj, Rahul
论文数: 0引用数: 0
h-index: 0
机构:
Loma Linda Univ Hlth, Cardiac Arrhythmia Serv, Div Cardiol, 11234 Anderson St, Loma Linda, CA 92354 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Bhardwaj, Rahul
[2
]
Contractor, Tahmeed
论文数: 0引用数: 0
h-index: 0
机构:
Loma Linda Univ Hlth, Cardiac Arrhythmia Serv, Div Cardiol, 11234 Anderson St, Loma Linda, CA 92354 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Contractor, Tahmeed
[2
]
Turagam, Mohit K.
论文数: 0引用数: 0
h-index: 0
机构:
Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY 10029 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Turagam, Mohit K.
[3
]
Mandapati, Ravi
论文数: 0引用数: 0
h-index: 0
机构:
Loma Linda Univ Hlth, Cardiac Arrhythmia Serv, Div Cardiol, 11234 Anderson St, Loma Linda, CA 92354 USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Mandapati, Ravi
[2
]
Lakkireddy, Dhanunjaya
论文数: 0引用数: 0
h-index: 0
机构:
Kansas City Heart Rhythm Inst & Res Fdn, Kansas City, KS USAOakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
Lakkireddy, Dhanunjaya
[4
]
论文数: 引用数:
h-index:
机构:
Garg, Jalaj
[2
]
机构:
[1] Oakland Univ William Beaumont, Sch Med, Beaumont Hosp, Dept Cardiovasc Med, Royal Oak, MI 48309 USA
[2] Loma Linda Univ Hlth, Cardiac Arrhythmia Serv, Div Cardiol, 11234 Anderson St, Loma Linda, CA 92354 USA
[3] Icahn Sch Med Mt Sinai, Helmsley Electrophysiol Ctr, New York, NY 10029 USA
[4] Kansas City Heart Rhythm Inst & Res Fdn, Kansas City, KS USA
Conduction system pacing;
Prosthetic heart valves;
Left bundle branch area pacing;
D O I:
10.1007/s10840-022-01228-7
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background There has been increasing interest in physiologic pacing techniques that directly activate the specialized conduction system. We aimed to assess outcomes of conduction system pacing (CSP) in patients with prosthetic heart valves. Methods This systematic review was performed according to PRISMA guidelines. Freeman-Tukey double arcsine transformation with the random-effect model was used to summarize the data. Outcomes studied were 1) implant success (defined as ability to recruit the His-Purkinje system or the distal Purkinje system); (2) lead parameters at implant and follow-up; and (3) procedure-related complications. Results This systematic review of 7 studies included 267 unique patients in whom CSP was attempted with either HBP or LBBAP for pacing indications after a prosthetic valve. HBP was attempted in 38% (n = 108), while LBBAP in 62% (n = 175) patients. The overall success rate of CSP was 87%, while in patients post-TAVR, the overall success rate was 83.2%. In the subgroup analysis, LBBAP had a significant higher overall success rate compared to HBP (94.3% vs. 76.5%, p (interaction) = 0.02) and post-TAVR patients (94.3 vs. 66.9%, p (interaction) < 0.01), respectively. The LBBAP thresholds were significantly lower compared to HBP both at implant (0.67 +/- 0.4 @ 0.44 ms vs. 1.35 +/- 1 @ 0.85 ms, p (interaction) < 0.01) and at a mean follow-up of 12.4 +/- 8 months (0.73 +/- 0.1 @ 0.44 ms vs. 1.39 +/- 1 @ 0.85 ms, p (interaction) < 0.01), respectively. Conclusion CSP is safe and feasible in patients with a prosthetic valve, with a significantly higher success rate and superior lead parameters with LBBAP than HBP, especially in patients post-TAVR.
机构:
Department of Mechanical Engineering, Trent Polytechnic, Nottingham, United KingdomDepartment of Mechanical Engineering, Trent Polytechnic, Nottingham, United Kingdom
Gentle, C.R.
Engineering in Medicine,
1987,
16
(02):
: 115
-
117
机构:
Univ Paris 05, Hop Europeen Georges Pompidou, Dept Cardiol, F-75908 Paris 15, FranceUniv Paris 05, Hop Europeen Georges Pompidou, Dept Cardiol, F-75908 Paris 15, France
Marijon, Eloi
Combes, Nicolas
论文数: 0引用数: 0
h-index: 0
机构:
Clin Pasteur, Dept Rythmol, Toulouse, FranceUniv Paris 05, Hop Europeen Georges Pompidou, Dept Cardiol, F-75908 Paris 15, France