Rapid Photoacoustic Exhaust Gas Analyzer for Simultaneous Measurement of Nitrogen Dioxide and Sulfur Dioxide

被引:13
|
作者
Qi, Hongchao [1 ]
Zhao, Xinyu [1 ]
Xu, Yufu [1 ]
Yang, Ling [2 ]
Liu, Junjun [3 ]
Chen, Ke [1 ]
机构
[1] Dalian Univ Technol, Sch Optoelect Engn & Instrumentat Sci, Dalian 116024, Liaoning, Peoples R China
[2] CSIC, Purificat Equipment Res Inst, Handan 056004, Hebei, Peoples R China
[3] Chengshan Grp Co Ltd, Rongcheng 264300, Shandong, Peoples R China
基金
中国国家自然科学基金;
关键词
NO2; SENSOR; SO2; SPECTROSCOPY; ABSORPTION; ACID; CO2;
D O I
10.1021/acs.analchem.3c05936
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid photoacoustic (PA) exhaust gas analyzer is presented for simultaneous measurements of nitrogen dioxide (NO2) and sulfur dioxide (SO2). A laser diode (LD) emitting at 450 nm and a light-emitting diode (LED) with a peak wavelength of 275 nm operated simultaneously, producing PA signals of NO2 and SO2, respectively. The LD and LED were modulated at different frequencies of 2568 and 2570 Hz, and their emission light beams were transmitted through two resonant tubes in a differential PA cell (DPAC), respectively. A self-made dual-channel digital lock-in amplifier was used to realize the simultaneous detection of dual-frequency PA signals. Cross interference between the PA signals at the two different frequencies was reduced to 0.02% by using a lock-in amplifier. In order to achieve a rapid dynamic measurement, gas sampling was accelerated by an air pump. The use of mufflers and the differential PA detection technique significantly reduced the gas sampling noise. When the gas flow rate was 1000 sccm, the response time of the PA dual-gas analyzer was 8 and 17 s for NO2 and SO2, respectively. The minimum detection limits of NO2 and SO2 were 1.7 and 26.1 ppb when the averaging time of the system was 10 s, respectively. Due to the wide spectral bandwidth of the LED, NO2 produced an interference to the detection of SO2. The interference was reduced by the precise detection of NO2. Since the radiations of the LD and LED passed through two different PA tubes, the impact of NO2 photochemical dissociation caused by UV LED luminescence on NO2 gas detection was negligible. The sharing of the PA cell, the gas lines, and the signal processing modules significantly reduced the size and cost of the PA dual-gas analyzer.
引用
收藏
页码:5258 / 5264
页数:7
相关论文
共 50 条
  • [1] High-Precision Photoacoustic Nitrogen Dioxide Gas Analyzer for Fast Dynamic Measurement
    Qi, Hongchao
    Zhang, Guangyin
    Xu, Lin
    Yang, Ling
    Wang, Zhengzhi
    Xu, Yufu
    Chen, Ke
    [J]. ANALYTICAL CHEMISTRY, 2024, 96 (03) : 1354 - 1361
  • [2] Effects of Nitrogen Dioxide and Carbon Monoxide on the Determination of Sulfur Dioxide by Flue Gas Analyzer
    Bo Guo
    Sisi Xu
    Qing Yu
    Feng Sui
    Aihua Xu
    Ningning Zhou
    [J]. MAPAN, 2017, 32 : 265 - 271
  • [3] Effects of Nitrogen Dioxide and Carbon Monoxide on the Determination of Sulfur Dioxide by Flue Gas Analyzer
    Guo, Bo
    Xu, Sisi
    Yu, Qing
    Sui, Feng
    Xu, Aihua
    Zhou, Ningning
    [J]. MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2017, 32 (04): : 265 - 271
  • [4] Research in Automobile Exhaust Gas of Sulfur Dioxide and Nitrogen Dioxide Monitoring WSN and Optimization Coverage Algorithm
    Zhou Yushan
    Zhang Yiwei
    Chu Linlin
    Liu Congning
    Shi Yunbo
    [J]. 2015 FIFTH INTERNATIONAL CONFERENCE ON INSTRUMENTATION AND MEASUREMENT, COMPUTER, COMMUNICATION AND CONTROL (IMCCC), 2015, : 1202 - 1205
  • [5] GAS DETECTOR FOR SULFUR-DIOXIDE AND FOR NITROGEN-DIOXIDE
    LALAUZE, R
    MEUNIER, J
    REYMOND, JM
    SOUSTELLE, M
    [J]. ANALUSIS, 1979, 7 (11) : 489 - 493
  • [6] Simultaneous removal of nitrogen oxide/nitrogen dioxide/sulfur dioxide from gas streams by combined plasma scrubbing technology
    Chang, MB
    Lee, HM
    Wu, FL
    Lai, CR
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2004, 54 (08): : 941 - 949
  • [7] Miniaturized sulfur dioxide analyzer
    不详
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (01) : 15A - 15A
  • [8] Simple analyzer for continuous monitoring of sulfur dioxide in gas streams
    Marzouk, Sayed A. M.
    Al-Marzouqi, Mohamed H.
    Baomran, Samira M. S. M.
    [J]. MICROCHEMICAL JOURNAL, 2010, 95 (02) : 207 - 212
  • [9] Method verification and evaluation of measurement uncertainty for the detection of sulfur dioxide in the exhaust gas of steel industry
    Guo, Miao
    Wang, Li
    Wang, Qian
    Zhang, Xiao
    Gao, Yang
    Liu, Ying
    [J]. Chinese Journal of Analysis Laboratory, 2021, 40 (11): : 1275 - 1278
  • [10] Simultaneous sulfur dioxide and nitrogen dioxide removal by calcium hydroxide and calcium silicate solids
    Nelli, CH
    Rochelle, GT
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1998, 48 (09): : 819 - 828