Intravascular Ultrasound Versus Computed Tomography Angiography in Sizing and Operative Management of Endovascular Aortic Aneurysm Repair

被引:6
|
作者
Taalab, Mohammad A. [1 ]
Kamal, Ahmed M. [2 ]
Mohammad, Ahmed F. [3 ]
Zaki, Mohamed M. [3 ]
机构
[1] Nasr City Hosp Hlth Insurance, Vasc Surg Dept, Cairo, Egypt
[2] Ain Shams Univ, El Demerdash Univ Hosp, Fac Med, Gen Surg Dept, Cairo, Egypt
[3] Ain Shams Univ, El Demerdash Univ Hosp, Fac Med, Vasc Surg Dept, Ramses St, Cairo 11566, Egypt
关键词
IVUS; intravascular ultrasound; EVAR; endovascular aortic aneurysm repair; CORONARY;
D O I
10.1177/15266028231158964
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objectives: An abdominal aortic aneurysm (AAA) is a potentially life-threatening condition, the management of which has dramatically evolved over the past 2 decades with an increasing tendency toward endovascular repair (EVAR) rather than open surgical repair. Classically, contrast-enhanced multislice computed tomography (CT) angiography (CTA) is performed preoperatively for procedure sizing and EVAR planning. This entails voluminous contrast injection with risk of allergic reaction, nephropathy, and radiation exposure. Intra-vascular ultrasound (IVUS) has been increasingly used to guide EVAR procedures intraoperatively. The aim of this study is to investigate the accuracy of IVUS in sizing AAAs, device selection, and EVAR planning compared to the gold standard CTA. Design: This is a prospective observational study enrolling 10 patients who underwent standard infrarenal EVAR procedures performed for unruptured infrarenal AAAs over the course of 1 year. All patients had a preoperative CTA done upon which aneurysm sizing and device planning were performed, and the measurements obtained were compared to those obtained from intraoperative IVUS. Methods: All participating patients had unruptured infrarenal AAA, had no renal impairment, and had anatomical suitability for EVAR according to the instructions for use (IFU) of the device manufacturer. Primary endpoint was comparing anatomical measurements recorded by IVUS with those obtained from the preoperative CTA. Results: Mean age was 65.6 (+/- 6.19), all patients were males and hypertensives and 4 (40%) had a positive family history for AAA. On comparing mean measurements taken by CTA and IVUS, there was no statistically significant differences with exception of maximal aortic diameter and aortic diameter at site of bifurcation (both p-values <.001). There were no statistically significant differences in length measurements between the 2 imaging modalities. Computed tomography angiography was more associated with neck thrombus detection, and IVUS was more associated with calcification detection. Conclusion: Although CT angiography is still the gold standard imaging modality for AAA, IVUS use is very beneficial in EVAR sizing and planning, in addition to intra-operative guidance of the procedure, saving the patient significant time, contrast administration, and radiation exposure, especially in patients with renal impairment and contrast allergy. Clinical Impact A preoperative CT angiogram is the gold standard required investigation for planning and sizing EVARs, with subsequent contrast injection entailing a risk of contrast induced nephropathy and allergic reactions. IVUS has been used as an adjuvant technique to guide EVAR stent graft deployment. However, our study concluded that it can also be reliably used in sizing and planning of the EVAR stent graft along with complementary non contrast imaging, especially in patients with high risk for contrast induced nephropathy and contrast allergy.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Computed tomography angiography as the basis for optimized therapy planning before endovascular aneurysm repair (EVAR)
    Strobl, F. F.
    Sommer, W. H.
    Haack, M.
    Nikolaou, K.
    Meimarakis, G.
    Koeppel, T. A.
    Weidenhagen, R.
    [J]. RADIOLOGE, 2013, 53 (06): : 495 - +
  • [42] Comparative Effectiveness of Intravascular Ultrasound versus Angiography in Abdominal and Thoracic Endovascular Aortic Repair: Systematic Review and Meta-Analysis
    Shimoda, Tomonari
    D'Oria, Mario
    Kuno, Toshiki
    Takagi, Hisato
    Heindel, Patrick
    Hussain, Mohamad
    Secemsky, Eric A.
    [J]. CIRCULATION, 2023, 148
  • [43] Snorkel endovascular abdominal aortic aneurysm repair versus fenestrated endovascular aneurysm repair: is it a competition?
    Tanious, Adam
    Lee, Jason T.
    Shames, Murray
    [J]. SEMINARS IN VASCULAR SURGERY, 2016, 29 (1-2) : 68 - 73
  • [44] Endovascular Aortic Aneurysm Repair and the Role of Ultrasound Surveillance
    Hartshorne, Tim
    [J]. ULTRASOUND, 2006, 14 (01) : 34 - 42
  • [45] Simultaneous sizing and preoperative risk stratification for thoracic endovascular aneurysm repair:: Role of gated computed tomography
    Schlosser, Felix J. V.
    Mojibian, Hamid R.
    Dardik, Alan
    Verhagen, Hence J. M.
    Moll, Frans L.
    Muhs, Bart E.
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (03) : 561 - 570
  • [46] Management of failed endovascular aortic aneurysm repair with explantation or fenestrated-branched endovascular aortic aneurysm repair
    Dias, Agenor P.
    Farivar, Behzad S.
    Steenberge, Sean P.
    Brier, Corey
    Kuramochi, Yuki
    Lyden, Sean P.
    Eagleton, Matthew J.
    [J]. JOURNAL OF VASCULAR SURGERY, 2018, 68 (06) : 1676 - +
  • [47] Ultrasound-determined diameter measurements are more accurate than axial computed tomography after endovascular aortic aneurysm repair
    Han, Sukgn M.
    Patel, Kaushel
    Rowe, Vincent L.
    Perese, Susana
    Bond, Aaron
    Weaver, Fred A.
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 51 (06) : 1381 - 1389
  • [48] A Comparison of Computed Tomography Angiography and Colour Duplex Ultrasound Surveillance Post Infrarenal Endovascular Aortic Aneurysm Repair: Financial Implications and Impact of Different International Surveillance Guidelines
    Smith, Luke
    Thomas, Nicholas
    Arnold, Andrew
    Bell, Rachel
    Zayed, Hany
    Tyrrell, Mark
    Padayachee, Soundrie
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2021, 62 (02) : 193 - 201
  • [49] The post-operative complications of endovascular aortic aneurysm repair
    Bown, MJ
    Fishwick, G
    Sayers, RD
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 2004, 45 (04): : 335 - 347
  • [50] Contrast Enhancement Boost Technique at Aortic Computed Tomography Angiography: Added Value for the Evaluation of Type II Endoleaks After Endovascular Aortic Aneurysm Repair
    Iizuka, Hitoshi
    Yokota, Yasuhiro
    Kidoh, Masafumi
    Oda, Seitaro
    Ikeda, Osamu
    Tamura, Yoshitaka
    Funama, Yoshinori
    Sakabe, Daisuke
    Nakaura, Takeshi
    Yamashita, Yasuyuki
    Utsunomiya, Daisuke
    [J]. ACADEMIC RADIOLOGY, 2019, 26 (11) : 1435 - 1440