Quantification of harmonic pollution using non-fundamental apparent power

被引:0
|
作者
Gopalapillai, Anu [1 ]
Fernandez, Francis M. [2 ]
机构
[1] APJ Abdul Kalam Technol Univ, Coll Engn Trivandrum, Dept Elect Engn, Trivandrum 695016, Kerala, India
[2] Coll Engn Trivandrum, Dept Elect Engn, Trivandrum 695016, Kerala, India
关键词
Apparent power; Distortion power; Harmonic distortion; Power quality; POINT; UTILITY; IDENTIFICATION; CUSTOMER;
D O I
10.1007/s00202-024-02267-1
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method to determine harmonic pollution of consumers connected to single-phase low voltage distribution system. Today, the power quality of the system is greatly affected due to the penetration of nonlinear loads. As per the IEEE standard 519-2014, both utility and consumers are responsible for reducing the harmonic pollution. This necessitates the quantification of harmonic contribution of individual consumers. The proposed method defines harmonic distortion indices for current and voltage separating consumer harmonic contribution at the point of common coupling (PCC). These indices are used to determine non-fundamental apparent power associated with each consumer connected to the PCC. Simulation results point to the effectiveness of this method in separating the harmonic contribution of consumer and utility. Experimental investigations are also carried out with several linear and nonlinear loads comparing the performance of the method with the power definitions mentioned in IEEE standard 1459-2010.
引用
收藏
页码:5303 / 5318
页数:16