Differential Effects on HbA1c Detection by HPLC and Capillary Electrophoresis in Five Types of Hb Variants in China

被引:0
|
作者
Luo Wei [1 ]
Zhang Weifeng [2 ]
Dong Zuoliang [1 ]
机构
[1] Tianjin Med Univ, Gen Hosp, Clin Lab Dept, Tianjin, Peoples R China
[2] Shandong Univ, Cheeloo Coll Med, Sch Basic Med Sci, Key Lab Expt Teratol,Minist Educ,Dept Biochem & M, Jinan, Peoples R China
关键词
HbA1c; hemoglobin; variants; sequencing; HPLC; capillary electrophoresis;
D O I
10.1093/labmed/lmac121
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective Hemoglobin A1c (HbA1c) can be used to evaluate blood glucose control. Its measurement will be affected by many factors, but Hb variation is the most critical factor. This study aimed to explore the types of variants found in routine work and their impact on test results. Methods Samples with abnormal HbA1c chromatograms found in routine testing were tested with high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) and then further tested with polymerase chain reaction (PCR) and sequencing. Results Five recessive heterozygous mutations were identified after PCR and sequencing. Hb Riccarton-II (a mutation in the HBA2 gene), Hb E, Hb G-Coushatta, Hb G-Taipei, and Hb North Manchester (a mutation in the HbB gene) were identified. All HbA1c values of these variants detected by HLC-723 G8 (HPLC method) were lower than those of Sebia Capillarys 2 FP (C2FP, CE method) with P Conclusion Five Hb mutations were identified in our routine HbA1c test, and their HPLC detection values were significantly lower than those obtained with the CE method.
引用
收藏
页码:308 / 316
页数:9
相关论文
共 50 条
  • [31] A field effect transistor (FET)-based immunosensor for detection of HbA1c and Hb
    Chao Bian
    Jianhua Tong
    Jizhou Sun
    Hong Zhang
    Qiannan Xue
    Shanhong Xia
    Biomedical Microdevices, 2011, 13 : 345 - 352
  • [32] Effects of common hemoglobin variants on HbA1c measurements in China: results for α- and β-globin variants measured by six methods
    Xu, Anping
    Chen, Weidong
    Xia, Yong
    Zhou, Yu
    Ji, Ling
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (08) : 1353 - 1361
  • [33] A field effect transistor (FET)-based immunosensor for detection of HbA1c and Hb
    Bian, Chao
    Tong, Jianhua
    Sun, Jizhou
    Zhang, Hong
    Xue, Qiannan
    Xia, Shanhong
    BIOMEDICAL MICRODEVICES, 2011, 13 (02) : 345 - 352
  • [34] NEXT GENERATION OF SEPARATION METHOD FOR HBA1C: FIRST EVALUATION OF THE CAPILLARY ELECTROPHORESIS TECHNIQUE
    Gillery, P.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S165 - S165
  • [35] Impact of carbamylation on three different methods, HPLC, capillary electrophoresis and TINIA of measuring HbA1c levels in patients with kidney disease
    Dolscheid-Pommerich, Ramona C.
    Kirchner, Sonja
    Weigel, Carola
    Eichhorn, Lars
    Conrad, Rupert
    Stoffel-Wagner, Birgit
    Zur, Berndt
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2015, 108 (01) : 15 - 22
  • [36] Effect of Hb H on HbA1c measurements as measured by IFCC reference method and affinity HPLC
    Li, Qing
    Tang, Juan
    Ju, Yi
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2016, 54 (08) : E231 - E233
  • [37] Effects of the Hb E, Hb H and Hb G-Taichung variants on HbA1c values by the Bio-Rad variant™ II turbo analyzer
    Lee, Su-Chen
    Wang, Li-Hsuan
    Tsai, Shih-Meng
    Fang, Hung-Yao
    Tsai, Li-Yu
    CLINICAL BIOCHEMISTRY, 2011, 44 (16) : 1338 - 1342
  • [38] Normal glucose tolerance with high HbA1c levels observed in two cases of Hb variants
    Tomita M.
    Kabeya Y.
    Okada K.
    Shirai M.
    Asai S.
    Katsuki T.
    Oikawa Y.
    Shimada A.
    Harano K.
    Atsumi Y.
    Diabetology International, 2010, 1 (2) : 104 - 107
  • [39] Identification of Hb Wayne and its effects on HbA1c measurement by 5 methods
    Rodriguez-Capote, Karina
    Estey, Mathew P.
    Barakauskas, Vilte E.
    Burton, Teralee
    Holmes, Deborah
    Krause, Richard
    Higgins, Trefor N.
    CLINICAL BIOCHEMISTRY, 2015, 48 (16-17) : 1144 - 1150
  • [40] Effects of hemoglobin (Hb) E and HbD traits on measurements of glycated Hb (HbA1c) by 23 methods
    Little, Randie R.
    Rohlfing, Curt L.
    Hanson, Steve
    Connolly, Shawn
    Higgins, Trefor
    Weykamp, Cas W.
    D'Costa, Mario
    Luzzi, Veronica
    Owen, William E.
    Roberts, William L.
    CLINICAL CHEMISTRY, 2008, 54 (08) : 1277 - 1282