Differential Effects on HbA1c Detection by HPLC and Capillary Electrophoresis in Five Types of Hb Variants in China

被引:0
|
作者
Luo Wei [1 ]
Zhang Weifeng [2 ]
Dong Zuoliang [1 ]
机构
[1] Tianjin Med Univ, Gen Hosp, Clin Lab Dept, Tianjin, Peoples R China
[2] Shandong Univ, Cheeloo Coll Med, Sch Basic Med Sci, Key Lab Expt Teratol,Minist Educ,Dept Biochem & M, Jinan, Peoples R China
关键词
HbA1c; hemoglobin; variants; sequencing; HPLC; capillary electrophoresis;
D O I
10.1093/labmed/lmac121
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective Hemoglobin A1c (HbA1c) can be used to evaluate blood glucose control. Its measurement will be affected by many factors, but Hb variation is the most critical factor. This study aimed to explore the types of variants found in routine work and their impact on test results. Methods Samples with abnormal HbA1c chromatograms found in routine testing were tested with high-performance liquid chromatography (HPLC) and capillary electrophoresis (CE) and then further tested with polymerase chain reaction (PCR) and sequencing. Results Five recessive heterozygous mutations were identified after PCR and sequencing. Hb Riccarton-II (a mutation in the HBA2 gene), Hb E, Hb G-Coushatta, Hb G-Taipei, and Hb North Manchester (a mutation in the HbB gene) were identified. All HbA1c values of these variants detected by HLC-723 G8 (HPLC method) were lower than those of Sebia Capillarys 2 FP (C2FP, CE method) with P Conclusion Five Hb mutations were identified in our routine HbA1c test, and their HPLC detection values were significantly lower than those obtained with the CE method.
引用
收藏
页码:308 / 316
页数:9
相关论文
共 50 条
  • [1] The effects of hemoglobin variants on measurements of HbA1C by HPLC
    Seydel, G. S.
    Guzelgul, F.
    Yalin, E.
    Sonmez, E.
    Aksoy, K.
    FEBS JOURNAL, 2016, 283 : 366 - 366
  • [2] Hb variants in Korea: effect on HbA1c using five routine methods
    Yun, Yeo-Min
    Ji, Misuk
    Ko, Dae-Hyun
    Chun, Sail
    Kwon, Gye Cheol
    Lee, Kyunghoon
    Song, Sang Hoon
    Seong, Moon Woo
    Park, Sung Sup
    Song, Junghan
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2017, 55 (08) : 1234 - 1242
  • [3] Detection of haemoglobin variants through the analysis of HbA1c by HPLC
    Lopez Medina, J. A.
    Cortes Rodriguez, M.
    Perez Nevot, B.
    Mayor Reyes, M.
    Pena Agueera, A.
    Garcia Almeida, J. M.
    Tinahones Madueno, F.
    DIABETOLOGIA, 2012, 55 : S128 - S128
  • [4] Influence of RBC Indices on HbA1c Measurement by Capillary Electrophoresis and HPLC Methods
    Juang, Yi-Jie
    Wu, Hsin-Mian
    Cheng, Ya-Wen
    Eng, Hock-Liew
    Lin, Tsun-Mei
    CLINICAL LABORATORY, 2022, 68 (08) : 1657 - 1665
  • [5] Effect of HB variants on HbA1c assays in Korea
    Lee, K.
    Kim, S.
    Jun, S.
    Song, S. H.
    Klopprogge, K.
    Song, J.
    CLINICA CHIMICA ACTA, 2019, 493 : S301 - S302
  • [6] INTERFERENCE ON HbA1C MEASUREMENT BY HPLC: HB D
    Kalayci, Mehmet
    Ayyildiz, Hakan
    Bozkurt, Mahmut
    Timurkaan, Mustafa
    NOBEL MEDICUS, 2016, 12 (02): : 66 - 68
  • [7] New HPLC instrument performance evaluation in HbA1c determination and comparison with capillary electrophoresis
    Khashoggi, Haneen
    Pignalosa, Stefano
    Russo, Carmelo
    Pieri, Massimo
    Bernardini, Sergio
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2018, 78 (05): : 393 - 397
  • [8] High-Resolution HbA1c Separation and Hemoglobinopathy Detection With Capillary Electrophoresis
    Urrechaga, Eloisa
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 (03) : 448 - 456
  • [9] Capillary blood HbA1c measurement by HPLC.
    Arribas, I
    Ruiz-Alvarez, MJ
    Franco, P
    Gómez-Sereno, B
    Gaspar, MJ
    Varela, LA
    Ramírez, J
    Coca, MC
    CLINICAL CHEMISTRY, 2003, 49 (06) : A129 - A129
  • [10] Performances of Capillary Electrophoresis and HPLC Methods in HbA1c Determination: Diagnostic Accuracy in HbS and HbD-Iran Variants' Presence
    Dessi, Mariarita
    Pieri, Massimo
    Pignalosa, Stefano
    Martino, Francesca Gabriela
    Zenobi, Rossella
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2015, 29 (01) : 57 - 60