Unveiling Peripherally Inserted Central Catheter Fractures and Related Complications in the Neonatal Intensive Care Unit: A Concise Review

被引:1
|
作者
Balasundaram, Palanikumar [1 ]
Lucena, Michelle H. [2 ]
Jiang, Lan [3 ]
Nafday, Suhas [4 ]
机构
[1] Javon Bea Hosp Riverside, Mercy Hlth Syst, Dept Pediat, Div Neonatol, Rockford, IL 61114 USA
[2] Baylor Coll Med, Texas Childrens Hosp, Dept Pediat, Div Neonatol, Houston, TX USA
[3] Albert Einstein Coll Med, Childrens Hosp Montefiore, Dept Pediat, Bronx, NY USA
[4] Albert Einstein Coll Med, Jack D Weiler Hosp, Childrens Hosp Montefiore, Dept Pediat,Div Neonatol, Bronx, NY USA
关键词
neonatal intensive care unit (nicu); catheter jamming; fracture; picc line complication; peripherally inserted central catheter (picc); CENTRAL VENOUS CATHETER; PERCUTANEOUS RETRIEVAL; SILASTIC CATHETER; REMOVAL; EMBOLIZATION; RETENTION; CHILDREN;
D O I
10.7759/cureus.47572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripherally inserted central catheters (PICCs) have become popular over tunneled catheters in neonatal intensive care units (NICUs) due to their ease of use and convenience. Although rare, a PICC fracture can be a severe and potentially fatal complication. This narrative review aims to identify factors predisposing neonates to PICC fracture and related complications, such as catheter jamming, and explore strategies for preventing and detecting this complication. A thorough search of PubMed and Google Scholar was conducted using relevant keywords to identify articles discussing PICC fracture in neonates. The review encompassed English-language literature on PICC fracture in neonates, with additional pertinent publications identified through citation searching. The incidence of PICC fracture in neonates varies from less than 1% to 10%, with a higher risk associated with prolonged catheterization, lower gestational age and lower birth weight, and the use of multi-lumen catheters. PICC fractures can occur during insertion, maintenance, or removal. Factors such as catheter duration, gestational age, birth weight, and catheter type increase the risk of PICC fracture. Excessive syringe pressure, securement failure, and excessive force during removal are contributing factors. Catheter fatigue and thin-walled catheter design are common causes of breakage. Preventive measures include proper training of healthcare providers, regular monitoring, early recognition, and prompt catheter removal upon fracture. Preventing and detecting PICC fractures is crucial for neonatal safety. Vigilance during insertion, maintenance, and removal, along with care to avoid excessive force during removal and high pressure during flushing, can help prevent catheter breakage. More research is required to improve prevention strategies for PICC fractures in neonates.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Intravascular catheter complications in the neonatal intensive care unit
    Hermansen, MC
    Hermansen, MG
    [J]. CLINICS IN PERINATOLOGY, 2005, 32 (01) : 141 - +
  • [22] Peripherally inserted central catheter care in neonates: an integrative literature review
    Johann, Derdried Athanasio
    Marques De Lazzari, Luciana Souza
    Pedrolo, Edivane
    Mingorance, Priscila
    Ribeiro de Almeida, Tatiana Queiroz
    Reichembach Danski, Mitzy Tannia
    [J]. REVISTA DA ESCOLA DE ENFERMAGEM DA USP, 2012, 46 (06) : 1502 - 1510
  • [23] Peripherally inserted central venous catheter-associated complications exert negative effects on body weight gain in neonatal intensive care units
    Wen, Jie
    Yu, Qun
    Chen, Haiyan
    Chen, Niannian
    Huang, Shourong
    Cai, Wei
    [J]. ASIA PACIFIC JOURNAL OF CLINICAL NUTRITION, 2017, 26 (01) : 1 - 5
  • [24] Peripherally Inserted Central Catheter lines for Intensive Care Unit and onco-hematologic patients: A systematic review and meta-analysis
    Mavrovounis, Georgios
    Mermiri, Maria
    Chatzis, Dimitrios G.
    Pantazopoulos, Loannis
    [J]. HEART & LUNG, 2020, 49 (06): : 922 - 933
  • [25] Application of peripherally inserted central catheters in critically ill newborns experience from a neonatal intensive care unit
    Li, Renfeng
    Cao, Xia
    Shi, Tian
    Xiong, Lei
    [J]. MEDICINE, 2019, 98 (32)
  • [26] Peripherally inserted central catheter (PICC) complications during pregnancy
    Cape, Alison
    Mogensen, Kris
    Robinson, Malcolm
    Carusi, Daniela
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2007, 197 (06) : S119 - S119
  • [27] Neonatal Anthropometric Measures and Peripherally Inserted Central Catheter Depth
    Armbruster, Debra
    Slaughter, Jonathan
    Stenger, Michael
    Warren, Patrick
    [J]. ADVANCES IN NEONATAL CARE, 2021, 21 (04) : 314 - 321
  • [28] Risk factors for peripherally inserted central catheter complications in neonates
    Pet, Gillian C.
    Eickhoff, Jens C.
    McNevin, Kate E.
    Do, Julie
    McAdams, Ryan M.
    [J]. JOURNAL OF PERINATOLOGY, 2020, 40 (04) : 581 - 588
  • [29] Risk factors for peripherally inserted central catheter line-related deep venous thrombosis in critically ill intensive care unit patients
    Bhargava, M.
    Broccard, S.
    Bai, Y.
    Wu, B.
    Dincer, E. H.
    Broccard, A.
    [J]. SAGE OPEN MEDICINE, 2020, 8
  • [30] Neonatal Anthropometric Measures and Peripherally Inserted Central Catheter Depth
    Armbruster, Debra
    Stenger, Michael
    Warren, Patrick
    Slaughter, Jonathan
    [J]. ADVANCES IN NEONATAL CARE, 2019, 19 (03) : E3 - E3