Unveiling Peripherally Inserted Central Catheter Fractures and Related Complications in the Neonatal Intensive Care Unit: A Concise Review

被引:1
|
作者
Balasundaram, Palanikumar [1 ]
Lucena, Michelle H. [2 ]
Jiang, Lan [3 ]
Nafday, Suhas [4 ]
机构
[1] Javon Bea Hosp Riverside, Mercy Hlth Syst, Dept Pediat, Div Neonatol, Rockford, IL 61114 USA
[2] Baylor Coll Med, Texas Childrens Hosp, Dept Pediat, Div Neonatol, Houston, TX USA
[3] Albert Einstein Coll Med, Childrens Hosp Montefiore, Dept Pediat, Bronx, NY USA
[4] Albert Einstein Coll Med, Jack D Weiler Hosp, Childrens Hosp Montefiore, Dept Pediat,Div Neonatol, Bronx, NY USA
关键词
neonatal intensive care unit (nicu); catheter jamming; fracture; picc line complication; peripherally inserted central catheter (picc); CENTRAL VENOUS CATHETER; PERCUTANEOUS RETRIEVAL; SILASTIC CATHETER; REMOVAL; EMBOLIZATION; RETENTION; CHILDREN;
D O I
10.7759/cureus.47572
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Peripherally inserted central catheters (PICCs) have become popular over tunneled catheters in neonatal intensive care units (NICUs) due to their ease of use and convenience. Although rare, a PICC fracture can be a severe and potentially fatal complication. This narrative review aims to identify factors predisposing neonates to PICC fracture and related complications, such as catheter jamming, and explore strategies for preventing and detecting this complication. A thorough search of PubMed and Google Scholar was conducted using relevant keywords to identify articles discussing PICC fracture in neonates. The review encompassed English-language literature on PICC fracture in neonates, with additional pertinent publications identified through citation searching. The incidence of PICC fracture in neonates varies from less than 1% to 10%, with a higher risk associated with prolonged catheterization, lower gestational age and lower birth weight, and the use of multi-lumen catheters. PICC fractures can occur during insertion, maintenance, or removal. Factors such as catheter duration, gestational age, birth weight, and catheter type increase the risk of PICC fracture. Excessive syringe pressure, securement failure, and excessive force during removal are contributing factors. Catheter fatigue and thin-walled catheter design are common causes of breakage. Preventive measures include proper training of healthcare providers, regular monitoring, early recognition, and prompt catheter removal upon fracture. Preventing and detecting PICC fractures is crucial for neonatal safety. Vigilance during insertion, maintenance, and removal, along with care to avoid excessive force during removal and high pressure during flushing, can help prevent catheter breakage. More research is required to improve prevention strategies for PICC fractures in neonates.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Inpatient Peripherally Inserted Central Venous Catheter Complications: Should Peripherally Inserted Central Catheter Lines Be Placed in the Intensive Care Unit Setting?
    Martyak, Michael
    Kabir, Ishraq
    Britt, Rebecca
    [J]. AMERICAN SURGEON, 2017, 83 (08) : 925 - 927
  • [2] Complications of peripherally inserted central venous catheter in Japanese neonatal intensive care units
    Ohki, Yasushi
    Maruyama, Kenichi
    Harigaya, Akira
    Kohno, Miyuki
    Arakawa, Hirokazu
    [J]. PEDIATRICS INTERNATIONAL, 2013, 55 (02) : 185 - 189
  • [3] Use of peripherally inserted central catheter (PICC) in a Brazilian Neonatal Intensive Care Unit (NICU)
    Draque, C. M.
    Richtmann, R.
    Arriero, G. D.
    Pirollo, R. P.
    Lima, E. V.
    [J]. ACTA PAEDIATRICA, 2007, 96 : 186 - 187
  • [4] Reducing peripherally inserted central catheters in the neonatal intensive care unit
    Vachharajani, A. J.
    Vachharajani, N. A.
    Morris, H.
    Niesen, A.
    Elward, A.
    Linck, D. A.
    Mathur, A. M.
    [J]. JOURNAL OF PERINATOLOGY, 2017, 37 (04) : 409 - 413
  • [5] Reducing peripherally inserted central catheters in the neonatal intensive care unit
    A J Vachharajani
    N A Vachharajani
    H Morris
    A Niesen
    A Elward
    D A Linck
    A M Mathur
    [J]. Journal of Perinatology, 2017, 37 : 409 - 413
  • [6] Developing a Nurse-Directed Peripherally Inserted Central Catheter Team in the Neonatal Intensive Care Unit
    Sharpe, Elizabeth L.
    [J]. NEWBORN AND INFANT NURSING REVIEWS, 2006, 6 (04) : 225 - 229
  • [7] Safety of fentanyl for peripherally inserted central catheter in non-intubated infants in the neonatal intensive care unit
    Yair Kasirer
    Vibhuti Shah
    Eugene W. Yoon
    Ruben Bromiker
    Carol Mcnair
    Anna Taddio
    [J]. Journal of Perinatology, 2018, 38 : 526 - 529
  • [8] Safety of fentanyl for peripherally inserted central catheter in non-intubated infants in the neonatal intensive care unit
    Kasirer, Yair
    Shah, Vibhuti
    Yoon, Eugene W.
    Bromiker, Ruben
    Mcnair, Carol
    Taddio, Anna
    [J]. JOURNAL OF PERINATOLOGY, 2018, 38 (05) : 526 - 529
  • [9] Management practices of Peripherally Inserted Central Catheter at a neonatal unit
    Dorea, Eny
    de Castro, Talita Elci
    Costa, Priscila
    Kimura, Amelia Fumiko
    Gaspar dos Santosiv, Fernanda Matilde
    [J]. REVISTA BRASILEIRA DE ENFERMAGEM, 2011, 64 (06) : 997 - 1002
  • [10] Assessment of the complications of peripherally inserted central catheter in neonates admitted to the intensive care unit: A center's experience in Iran
    Moradi, Raheleh
    Shariat, Mamak
    Farrokhzad, Nahid
    Abroon, Ameneh
    Kafi, Soheila
    Hamidpoor, Azadeh
    Hassani, Elaheh
    Charousaei, Hasti
    Nayeri, Fatemeh Sadat
    [J]. IRANIAN JOURNAL OF NURSING AND MIDWIFERY RESEARCH, 2022, 27 (06) : 505 - 508