Automatic assessment of left ventricular function for hemodynamic monitoring using artificial intelligence and transesophageal echocardiography

被引:7
|
作者
Yu, Jinyang [1 ,4 ]
Tasken, Anders Austlid [3 ]
Flade, Hans Martin [1 ,2 ]
Skogvoll, Eirik [1 ,2 ]
Berg, Erik Andreas Rye [1 ,4 ]
Grenne, Bjornar [1 ,4 ]
Rimehaug, Audun [1 ,2 ]
Kirkeby-Garstad, Idar [1 ]
Kiss, Gabriel [3 ]
Aakhus, Svend [1 ,4 ]
机构
[1] Norwegian Univ Sci & Technol, Dept Circulat & Med Imaging, Trondheim, Norway
[2] Trondheim Reg & Univ Hosp, St Olavs Hosp, Dept Anesthesia & Intens Care, Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Dept Comp Sci, Trondheim, Norway
[4] Trondheim Reg & Univ Hosp, St Olavs Hosp, Clin Cardiol, Trondheim, Norway
关键词
Artificial intelligence; Circulatory failure; Critical care; Hemodynamic monitoring; Left ventricular function; Transesophageal echocardiography; SAFETY; REPRODUCIBILITY; AGREEMENT; SOCIETY; UTILITY; IMPACT;
D O I
10.1007/s10877-023-01118-x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
We have developed a method to automatically assess LV function by measuring mitral annular plane systolic excursion (MAPSE) using artificial intelligence and transesophageal echocardiography (autoMAPSE). Our aim was to evaluate autoMAPSE as an automatic tool for rapid and quantitative assessment of LV function in critical care patients. In this retrospective study, we studied 40 critical care patients immediately after cardiac surgery. First, we recorded a set of echocardiographic data, consisting of three consecutive beats of midesophageal two- and four-chamber views. We then altered the patient's hemodynamics by positioning them in anti-Trendelenburg and repeated the recordings. We measured MAPSE manually and used autoMAPSE in all available heartbeats and in four LV walls. To assess the agreement with manual measurements, we used a modified Bland-Altman analysis. To assess the precision of each method, we calculated the least significant change (LSC). Finally, to assess trending ability, we calculated the concordance rates using a four-quadrant plot. We found that autoMAPSE measured MAPSE in almost every set of two- and four-chamber views (feasibility 95%). It took less than a second to measure and average MAPSE over three heartbeats. AutoMAPSE had a low bias (0.4 mm) and acceptable limits of agreement (- 3.7 to 4.5 mm). AutoMAPSE was more precise than manual measurements if it averaged more heartbeats. AutoMAPSE had acceptable trending ability (concordance rate 81%) during hemodynamic alterations. In conclusion, autoMAPSE is feasible as an automatic tool for rapid and quantitative assessment of LV function, indicating its potential for hemodynamic monitoring.
引用
收藏
页码:281 / 291
页数:11
相关论文
共 50 条
  • [41] Seeing is believing: A call for routine early postoperative hemodynamic transesophageal echocardiography monitoring after left ventricular assist device implantation?
    Pulido, Juan N.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2018, 155 (03): : 1078 - 1079
  • [42] Evaluation of Cardiac Function of the Patients with Left Ventricular Assist Device by Transesophageal Echocardiography
    Saijo, Y.
    Saiki, Y.
    Iguchi, A.
    Tabayashi, K.
    Shiraishi, Y.
    Sekine, K.
    Yambe, T.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 4146 - +
  • [43] HEMODYNAMIC ASSESSMENT OF LEFT-VENTRICULAR FUNCTION IN HYPERTHYROIDISM
    MERILLON, JP
    PASSA, P
    WOLF, A
    GOURGON, R
    [J]. NOUVELLE PRESSE MEDICALE, 1982, 11 (28): : 2154 - 2154
  • [44] AN ARTIFICIAL INTELLIGENCE-ENABLED ECG ALGORITHM FOR LEFT VENTRICULAR DIASTOLIC FUNCTION ASSESSMENT
    Lee, Eunjung
    Ito, Saki
    Kane, Garvan C.
    Lopez-Jimenez, Francisco
    Friedman, Paul A.
    Attia, Zachi Itzhak
    Oh, Jae K.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 4023 - 4023
  • [45] Artificial Intelligence and Left Ventricular Diastolic Function Assessment: A New Tool for Improved Practice?
    Bellini, Valentina
    Sanfilippo, Filippo
    Vetrugno, Luigi
    Bignami, Elena
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2021, 35 (09) : 2834 - 2834
  • [46] Left ventricular global systolic function assessment by echocardiography
    Chengode, Suresh
    [J]. ANNALS OF CARDIAC ANAESTHESIA, 2016, 19 (05) : S20 - S28
  • [47] INTEREST OF ECHOCARDIOGRAPHY IN THE ASSESSMENT OF THE LEFT-VENTRICULAR FUNCTION
    GAYET, C
    PEARLMAN, AS
    WILNER, C
    ANDREFOUET, X
    [J]. LYON MEDICAL, 1983, 249 (04): : 111 - 119
  • [49] Intraoperative echocardiography assessment of left and right ventricular function
    Harvey, N. J.
    [J]. SOUTHERN AFRICAN JOURNAL OF ANAESTHESIA AND ANALGESIA, 2011, 17 (01) : 42 - 48
  • [50] Role of contrast echocardiography for the assessment of left ventricular function
    Senior, R
    [J]. ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 1999, 16 (07): : 747 - 752