Comprehensive Comparison of Continuous-Wave and Linear-Frequency-Modulated Continuous-Wave Radars for Short-Range Vital Sign Monitoring

被引:11
|
作者
Antolinos, Elias [1 ]
Grajal, Jesus [1 ]
机构
[1] Univ Politecn Madrid, Informat Proc & Telecommun Ctr, Madrid 28040, Spain
关键词
Radar; Radar applications; Monitoring; Baseband; Radar measurements; Radar antennas; Doppler radar; CW radar; HRV sequence; LFMCW radar; vital sign monitoring; ACCURATE MEASUREMENT; ARCHITECTURES; RECOGNITION;
D O I
10.1109/TBCAS.2023.3257647
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of radar technology for contactless monitoring of cardiorespiratory activity has been a significant research topic for the last two decades. However, despite the abundant literature focusing on the use of different radar architectures for healthcare applications, an in-depth analysis is missing about the most appropriate configuration. This article presents a comparison between continuous-wave (CW) and linear-frequency-modulated continuous-wave (LFMCW) radars for application in vital sign monitoring scenarios. These waveforms are generated with the same architecture at two different frequencies: 24 and 134 GHz. Results evidence that both configurations are capable of measuring general metrics, such as the breathing and heart rates. However, LFMCW offers better results in the identification of cardiac events and the extraction of certain derived biomarkers, such as the heart rate variability sequences (HRV). Conclusions show that this performance does not depend on the selected working frequency.
引用
收藏
页码:229 / 245
页数:17
相关论文
共 50 条
  • [31] Communications via Frequency-Modulated Continuous-Wave Radar in Millimeter Wave Band
    Fan, Yawen
    Bao, Jingchao
    Aljumaily, Mustafa S.
    Li, Husheng
    2019 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM), 2019,
  • [32] Coherence analysis of optical frequency-modulated continuous-wave interference
    Zheng, Jesse
    APPLIED OPTICS, 2006, 45 (16) : 3681 - 3687
  • [33] A frequency-modulated continuous-wave reflectometer for the Lithium Tokamak Experiment
    Kubota, S.
    Majeski, R.
    Peebles, W. A.
    Bell, R. E.
    Boyle, D. P.
    Kaita, R.
    Kozub, T.
    Lucia, M.
    Merino, E.
    Nguyen, X. V.
    Rhodes, T. L.
    Schmitt, J. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (05):
  • [34] Singlemode fibre frequency-modulated continuous-wave Sagnac gyroscope
    Zheng, J
    ELECTRONICS LETTERS, 2004, 40 (20) : 1255 - 1257
  • [35] Polarization decoherence differential frequency-modulated continuous-wave gyroscope
    Zheng, Chao
    Zheng, Gang
    Han, Liwei
    Luo, Jianhua
    Teng, Fei
    Wang, Bing
    Song, Ping
    Gao, Kun
    Hou, Zhiqing
    OPTICS LETTERS, 2014, 39 (23) : 6597 - 6599
  • [36] MATCHED FILTER FOR FREQUENCY-MODULATED CONTINUOUS-WAVE RADAR SYSTEMS
    WITHERS, MJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1966, 113 (03): : 405 - &
  • [37] Birefringent fibre frequency-modulated continuous-wave Sagnac gyroscope
    Zheng, J
    ELECTRONICS LETTERS, 2004, 40 (24) : 1520 - 1522
  • [38] Transformation of the frequency-modulated continuous-wave field into a train of short pulses by resonant filters
    Shakhmuratov, R. N.
    PHYSICAL REVIEW A, 2017, 95 (03)
  • [39] Time-Frequency-Modulated Metasurface for False Target Generation in Symmetrical Triangular LFM Continuous-Wave Radars
    Zhu, Yonggeng
    Fang, Xinyu
    Li, Mengmeng
    Ramaccia, Davide
    Toscano, Alessandro
    Bilotti, Filiberto
    Ding, Dazhi
    IEEE Transactions on Microwave Theory and Techniques, 2024,
  • [40] Time–Frequency-Modulated Metasurface for False Target Generation in Symmetrical Triangular LFM Continuous-Wave Radars
    Zhu, Yonggeng
    Fang, Xinyu
    Li, Mengmeng
    Ramaccia, Davide
    Toscano, Alessandro
    Bilotti, Filiberto
    Ding, Dazhi
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2024,