Pathological investigation for addressing abnormal or precancerous cells in cervix specimens is necessary to diagnose or treat. This process is exhaustive in histologic examination and requires experienced pathologists. Detecting the presence of precancerous cells with bioimpedance is another method to help pathologists by using a small-diameter probe to measure the impedance. However, it requires several measurements and is possibly another exhaustive task. This study proposed the localization of abnormal cells in a specimen using reconstruction images with Frequency-difference Electrical Impedance Tomography (fdEIT). Due to the various shape of specimens in practice, a new approach to cope with modeling error was also proposed to enable using a generic inversion model in the reconstruction process. Simulation of cervix specimens with different orifice shapes and thicknesses was performed. The proposed method was compared with the traditional methods i.e. the simple-fdEIT and the weighted-fdEIT. Amplitude response, radius, position error and ringing ratio of the reconstruction images were determined. The image reconstruction of the proposed method showed superior performance in localization. Although the image amplitude response was smaller, the artifacts that occurred due to modeling error were significantly reduced. Even though the shape of cervix specimens is varied, the proposed method allows to use a generic model for precancerous cells localization. The influence of modeling error can be reduced. Consequentially, the ringing artifact can be significantly reduced and the position error is also slightly reduced.
引用
收藏
页码:67745 / 67754
页数:10
相关论文
共 50 条
  • [1] Frequency-Difference Electrical Impedance Imaging of Cervical Specimens
    Ouypornkochagorn, Taweechai
    Ngamdi, Napatsawan
    Ouypornkochagorn, Sairoong
    Sriwilai, Jaruwan
    Trongwongsa, Therdkiat
    IEEE ACCESS, 2024, 12 : 92087 - 92097
  • [2] Combining frequency-difference and ultrasound modulated electrical impedance tomography
    Harrach, Bastian
    Lee, Eunjung
    Ullrich, Marcel
    INVERSE PROBLEMS, 2015, 31 (09)
  • [3] Multiple Weighted Frequency-difference Method for Electrical Impedance Tomography
    Hu, Qingwei
    Xu, Yanbin
    Liu, Ziqi
    Li, Changbin
    Dong, Feng
    2021 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2021), 2021,
  • [4] Frequency-difference electrical impedance tomography (fdEIT): algorithm development and feasibility study
    Seo, Jin Keun
    Lee, Jeehyun
    Kim, Sung Wan
    Zribi, Habib
    Woo, Eung Je
    PHYSIOLOGICAL MEASUREMENT, 2008, 29 (08) : 929 - 944
  • [5] Weighted Frequency-difference Electrical Impedance Tomography of Lung Based on RBFNN*
    Bai, Shi-Zhan
    Li, Wen-Sheng
    Lin, Hai-Jun
    Li, Jian-Min
    Zhang, Fu
    Yang, Yu-Xiang
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2023, 50 (07) : 1755 - 1766
  • [6] Method of Tikhonov Regularization for Weighted Frequency-Difference Electrical Impedance Tomography
    Han, Bing
    Xu, Yanbin
    Dong, Feng
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 242 - 247
  • [7] Asymptotic analysis of the membrane structure to sensitivity of frequency-difference electrical impedance tomography
    Kim, Sungwhan
    Lee, Eun Jung
    Woo, Eung Je
    Seo, Jin Keun
    INVERSE PROBLEMS, 2012, 28 (07)
  • [8] Factorization Method and Its Physical Justification in Frequency-Difference Electrical Impedance Tomography
    Harrach, Bastian
    Seo, Jin Keun
    Woo, Eung Je
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (11) : 1918 - 1926
  • [9] Frequency-Difference Electrical Impedance Imaging of Breast Specimens
    Ouypornkochagorn, Taweechai
    Ngamdi, Napatsawan
    Buathong, Piyathida
    Laor-Iam, Phanpasorn
    Phisaiphan, Aiyada
    Ouypornkochagorn, Sairoong
    Sriwilai, Jaruwan
    Trongwongsa, Therdkiat
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [10] Calibrated Frequency-Difference Electrical Impedance Tomography for 3D Tissue Culture Monitoring
    Wu, Hancong
    Yang, Yunjie
    Bagnaninchi, Pierre-Olivier
    Jia, Jiabin
    IEEE SENSORS JOURNAL, 2019, 19 (18) : 7813 - 7821