Virtual Laboratory for the Full-Field Goniophotometer of Luminaires

被引:0
|
作者
Liu, Shasha [1 ]
Cao, Fan [1 ]
He, Xiaoyang [1 ]
Zou, Nianyu [1 ]
机构
[1] Dalian Polytech Univ, Res Inst Photon, Dalian 116034, Peoples R China
来源
APPLIED SCIENCES-BASEL | 2023年 / 13卷 / 10期
关键词
virtual laboratory; full-field goniophotometer; unity; 3D;
D O I
10.3390/app13105899
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In order to solve the problem that students have insufficient understanding of the full-field goniophotometer instrumentation due to the expensive equipment and the high requirements of the experimental environment, virtual reality technology is used to complete the virtual laboratory of a light intensity distribution measurement of the full-field goniophotometer through Unity 3D. The virtual laboratory is designed for near-field measurement, mid-field measurement, and far-field measurement of light intensity. It combines 3D MAX and C# to realize the model building of laboratory, luminaire and full-field goniophotometer, the dynamic drawing of light distribution curves, and the simulation system can also be run on mobile phones. The experimental process is mainly through the manipulation of the virtual experimenter and each module to generate collision detection, pop-up buttons, and click on the button triggers an event and the operation prompt page appears. The light distribution curve is generated dynamically by reading and processing the IES file data to generate 3D coordinates. This virtual simulation laboratory is demonstrated on multiple platforms. The results proved that the virtual simulation restored the experimental process vividly and can complete the experimental teaching remotely.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Recording of the full-field electroretinogram in minipigs
    Augsburger, Anne-Sandrine
    Haag, Valerie
    Leuillet, Sebastien
    Legrand, Jean-Jacques
    Forster, Roy
    VETERINARY OPHTHALMOLOGY, 2012, 15 : 84 - 93
  • [32] FULL-FIELD SYSTEM FOR CLINICAL ELECTRORETINOGRAPHY
    RABIN, AR
    BERSON, EL
    ARCHIVES OF OPHTHALMOLOGY, 1974, 92 (01) : 59 - 63
  • [33] TOWARDS A FULL-FIELD COMPENSATION METHOD
    CERNOSEK, J
    EXPERIMENTAL MECHANICS, 1972, 12 (03) : 152 - &
  • [34] NEW METHOD FOR FULL-FIELD DIFFERENTIATION
    SEGALMAN, DJ
    WOYAK, DB
    ROWLANDS, RE
    EXPERIMENTAL MECHANICS, 1979, 19 (05) : N43 - N43
  • [35] Full-field perimetry in pituitary tumors
    Venugopal, N.
    NEUROLOGY INDIA, 2017, 65 (03)
  • [36] Full-field OCT finds fingerprints
    不详
    LASER FOCUS WORLD, 2007, 43 (12): : 13 - 13
  • [37] Full-field optical coherence microscopy
    Cent Natl de la Recherche, Paris, France
    Opt Lett, 4 (244-246):
  • [38] Intrasession variability of the full-field ERG
    Hochstein, Grant D.
    Molnar, Fanni E.
    Marmor, Michael F.
    DOCUMENTA OPHTHALMOLOGICA, 2007, 115 (02) : 77 - 83
  • [39] Full-field broadband invisibility cloaking
    Cortes, Luis Romero
    Maram, Reza
    Azana, Jose
    2016 IEEE PHOTONICS CONFERENCE (IPC), 2016, : 174 - 175
  • [40] Intrasession variability of the full-field ERG
    Grant D. Hochstein
    Fanni E. Molnar
    Michael F. Marmor
    Documenta Ophthalmologica, 2007, 115 : 77 - 83