Research on indoor thermal comfort of expressway service building based on SPMV

被引:1
|
作者
Jiao, Lichao [1 ]
Jiao, Lijun [2 ]
Ma, Dong [3 ]
Dong, Yingying [4 ]
机构
[1] Henan Univ Urban Construct, Sch Management, Pingdingshan 467036, Peoples R China
[2] Hengshui Univ, Sch Econ & Management, Hengshui, Peoples R China
[3] Henan Commun Planning & Design Inst Co Ltd, Zhengzhou, Peoples R China
[4] Henan Univ Urban Construct, Sch Mat & Chem Engn, Pingdingshan, Peoples R China
关键词
Expressway service building; Traveling route; Streamlined thermal comfort; Temperature frequency method; Temperature acceptable threshold;
D O I
10.1016/j.enbuild.2023.113830
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
According to the characteristics of "temporary stay" and "streamlined" passenger flow in expressway service buildings, this article uses the "streamlined thermal comfort" index to characterize the indoor thermal comfort condition of the buildings,to create an overall comfortable space based on the "streamline trajectory".The article proposes to divide comprehensive thermal comfort into "regional static thermal comfort" and "inter-zone dynamic thermal comfort", revise the existing PMV(Predicted Mean Vote) index, and integrate the characteristics of the two types of indicators to form a comprehensive thermal comfort evaluation index based on "passenger trajectory". The main work of this article includes: Firstly, using the temperature frequency method, a regression curve fitting between actual thermal sensation and indoor operative temperature is conducted to obtain the acceptable thresholds of MTS(Median Thermal Sensation), PMV neutral temperature, and actual temperature, forming a streamlined static thermal comfort index. The metabolic rate M value is segmented according to a 6minute stabilization time to form a streamlined dynamic thermal comfort index; Introduce the factor of regional residence time tau to form a comprehensive thermal comfort index for streamlining. Secondly, an empirical analysis was conducted on the revised indicators, and the measured TSV(Thermal Sensation Vote) = -1, 0, 1 curves under different operating conditions in summer and winter were fitted with the SPMV(StreamlinePredicted Mean Vote) curve, revealing that the error in each functional area was within 10 %. The analysis results show that the modified index SPMV has greatly improved its consistency with the measured thermal sensation TSV, and can be used to evaluate the indoor thermal comfort of expressway service buildings in cold regions.The research results have high practical value for creating comfortable indoor environments in different indoor spaces of transportation commercial complexes, and have universal significance for creating streamlined indoor dynamic comfortable environments in urban commercial complexes.
引用
收藏
页数:22
相关论文
共 50 条
  • [41] Virtual Building Dataset for energy and indoor thermal comfort benchmarking of office buildings in Greece
    Nikolaou, T.
    Skias, I.
    Kolokotsa, D.
    Stavrakakis, G.
    ENERGY AND BUILDINGS, 2009, 41 (12) : 1409 - 1416
  • [42] Indoor Thermal Comfort: The Behavioral Component
    Barkenbus, Jack
    SUSTAINABILITY, 2013, 5 (04) : 1680 - 1699
  • [43] Evaluation and control of indoor thermal comfort
    Lian, ZW
    Zhao, B
    Ye, XJ
    Liu, HM
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 1119 - 1122
  • [44] Theoretical Study on the Relationship of Building Thermal Insulation with Indoor Thermal Comfort Based on APMV Index and Energy Consumption of Rural Residential Buildings
    Nie, Jinzhe
    Pang, Yuxin
    Wang, Congcong
    Zhang, Han
    Yin, Kuichao
    APPLIED SCIENCES-BASEL, 2021, 11 (18):
  • [45] Evaluation of building thermal performance based on thermal comfort point of view
    School of Environmental and Municipal Engineering, Xi'an University of Architecture and Technology, Xi'an 710055, China
    J. Harbin Inst. Technol., 2007, SUPPL. (183-185):
  • [46] Indoor thermal comfort: the Pakistan study
    Nicol, J. Fergus
    Raja, Iftikhar A.
    Energy for Sustainable Development, 1997, 3 (05): : 50 - 60
  • [47] Interactive Indoor Thermal Comfort Evaluation
    van Treeck, Christoph
    Wenisch, Petra
    Pfaffinger, Michael
    Scheck, Leonhard
    Rank, Ernst
    HIGH PERFORMANCE COMPUTING IN SCIENCE AND ENGINEERING, GARCH/MUNICH 2007, 2009, : 421 - +
  • [48] Indoor environment, thermal comfort and productivity
    Ye, XJ
    Lian, ZW
    Zhou, ZP
    Feng, JM
    Li, CZ
    Liu, YM
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 407 - 411
  • [49] Research on the Environmental Thermal Comfort Based on Manikin
    Wang, Rui
    Zhao, Chaoyi
    Hu, Huimin
    Qiu, Yifen
    Cheng, Xueliang
    ADVANCES IN USABILITY, USER EXPERIENCE AND ASSISTIVE TECHNOLOGY, 2019, 794 : 916 - 924
  • [50] Advances in research for underground buildings: Energy, thermal comfort and indoor air quality
    Yu, Jia
    Kang, Yanming
    Zhai, Zhiqiang
    ENERGY AND BUILDINGS, 2020, 215