Image quality assessment of retinal fundus photographs for diabetic retinopathy in the machine learning era: a review

被引:4
|
作者
Goncalves, Mariana Batista [1 ,2 ,3 ,4 ]
Nakayama, Luis Filipe [1 ,5 ]
Ferraz, Daniel [1 ,2 ,3 ,4 ]
Faber, Hanna [6 ,7 ]
Korot, Edward [8 ,9 ]
Malerbi, Fernando Korn [1 ]
Regatieri, Caio Vinicius [1 ]
Maia, Mauricio [1 ]
Celi, Leo Anthony [5 ,10 ,11 ]
Keane, Pearse A. [3 ,4 ]
Belfort Jr, Rubens [1 ,2 ]
机构
[1] Sao Paulo Fed Univ, Dept Ophthalmol, Sao Paulo, SP, Brazil
[2] Vis Inst, Inst Paulista Estudos & Pesquisas Oftalmol, IPEPO, Sao Paulo, SP, Brazil
[3] Moorfield Eye Hosp, NHS Fdn Trust, NIHR Biomed Res Ctr Ophthalmol, London, England
[4] UCL Inst Ophthalmol, London, England
[5] MIT, Lab Computat Physiol, Cambridge, MA 02139 USA
[6] Univ Med Ctr Hamburg Eppendorf, Dept Ophthalmol, Hamburg, Germany
[7] Univ Tubingen, Dept Ophthalmol, Tubingen, Germany
[8] Retina Specialists Michigan, Grand Rapids, MI USA
[9] Stanford Univ, Byers Eye Inst, Palo Alto, CA USA
[10] Harvard TH Chan Sch Publ Hlth, Dept Biostat, Boston, MA USA
[11] Beth Israel Deaconess Med Ctr, Dept Med, Boston, MA USA
关键词
SCREENING-PROGRAM; VALIDATION; PERFORMANCE; HEAD;
D O I
10.1038/s41433-023-02717-3
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
This study aimed to evaluate the image quality assessment (IQA) and quality criteria employed in publicly available datasets for diabetic retinopathy (DR). A literature search strategy was used to identify relevant datasets, and 20 datasets were included in the analysis. Out of these, 12 datasets mentioned performing IQA, but only eight specified the quality criteria used. The reported quality criteria varied widely across datasets, and accessing the information was often challenging. The findings highlight the importance of IQA for AI model development while emphasizing the need for clear and accessible reporting of IQA information. The study suggests that automated quality assessments can be a valid alternative to manual labeling and emphasizes the importance of establishing quality standards based on population characteristics, clinical use, and research purposes. In conclusion, image quality assessment is important for AI model development; however, strict data quality standards must not limit data sharing. Given the importance of IQA for developing, validating, and implementing deep learning (DL) algorithms, it's recommended that this information be reported in a clear, specific, and accessible way whenever possible. Automated quality assessments are a valid alternative to the traditional manual labeling process, and quality standards should be determined according to population characteristics, clinical use, and research purpose.
引用
收藏
页码:426 / 433
页数:8
相关论文
共 50 条
  • [31] A Review of Fundus Image Analysis for the Automated Detection of Diabetic Retinopathy
    Noronha, Kevin
    Nayak, K. Prabhakar
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2012, 2 (03) : 258 - 265
  • [32] A review of automated diabetic retinopathy diagnosis from fundus image
    Narasimhan, K.
    Neha, V.C.
    Vjayarekha, K.
    [J]. Journal of Theoretical and Applied Information Technology, 2012, 39 (02) : 225 - 238
  • [33] Fundus Image Screening for Diabetic Retinopathy
    Li Jiayu
    Chen Minghui
    Yang Ruijun
    Ma Wenfei
    Lai Xiangling
    Huang Duowen
    Liu Duxin
    Ma Xinhong
    Shen Yue
    [J]. CHINESE JOURNAL OF LASERS-ZHONGGUO JIGUANG, 2022, 49 (11):
  • [34] DIABETIC RETINOPATHY ANALYSIS USING EXUDATE EXTRACTION FROM FUNDUS RETINAL IMAGE
    Nayagi, Bharani S.
    Selvarathi, C.
    [J]. INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2019, : 10 - 16
  • [35] RETRACTION: A Deep Learning Framework for Earlier Prediction of Diabetic Retinopathy from Fundus Photographs
    Gunasekaran, K.
    Pitchai, R.
    Chaitanya, G. K.
    [J]. BIOMED RESEARCH INTERNATIONAL, 2023, 2023
  • [36] Global Assessment of Retinal Arteriolar, Venular and Capillary Microcirculations Using Fundus Photographs and Optical Coherence Tomography Angiography in Diabetic Retinopathy
    Tan, Tien-En
    Quang Nguyen
    Chua, Jacqueline
    Schmetterer, Leopold
    Tan, Gavin Siew Wei
    Wong, Chee Wai
    Tsai, Andrew
    Cheung, Gemmy Chui Ming
    Wong, Tien Yin
    Ting, Daniel Shu Wei
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [37] Classification of Diabetic Retinopathy Using Textural Features in Retinal Color Fundus Image
    Padmanabha, Anantha A. G.
    Appaji, Abhishek M.
    Prasad, Mukesh
    Lu, Haiyan
    Joshi, Sudhanshu
    [J]. 2017 12TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND KNOWLEDGE ENGINEERING (IEEE ISKE), 2017,
  • [38] Reproduction study using public data of: Development and validation of a deep learning algorithm for detection of diabetic retinopathy in retinal fundus photographs
    Voets, Mike
    Mollersen, Kajsa
    Bongo, Lars Ailo
    [J]. PLOS ONE, 2019, 14 (06):
  • [39] Global Assessment of Retinal Arteriolar, Venular and Capillary Microcirculations Using Fundus Photographs and Optical Coherence Tomography Angiography in Diabetic Retinopathy
    Tien-En Tan
    Quang Nguyen
    Jacqueline Chua
    Leopold Schmetterer
    Gavin Siew Wei Tan
    Chee Wai Wong
    Andrew Tsai
    Gemmy Chui Ming Cheung
    Tien Yin Wong
    Daniel Shu Wei Ting
    [J]. Scientific Reports, 9
  • [40] Comparative study of different machine learning models for automatic diabetic retinopathy detection using fundus image
    Gupta, Shubhi
    Thakur, Sanjeev
    Gupta, Ashutosh
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 83 (12) : 34291 - 34322