Gas Loss Mechanism in the High-Pressure Air Cushion Surge Chamber of Hydropower Station for Transient Process

被引:1
|
作者
Xia, Yong [1 ]
Wang, Pei [2 ]
Du, Pengxia [3 ]
Liu, Yue [1 ]
Tang, Bihua [1 ]
Li, Xueyu [2 ]
Zhou, Ling [4 ,5 ]
Liu, Deyou [4 ]
机构
[1] Power China Chengdu Engn Corp Ltd, Chengdu 610072, Peoples R China
[2] Hohai Univ, Coll Energy & Elect Engn, Nanjing 210098, Peoples R China
[3] Huaneng Sichuan Energy Dev Co Ltd, Chengdu 610025, Peoples R China
[4] Hohai Univ, Coll Water Conservancy & Hydropower Engn, Nanjing 210098, Peoples R China
[5] Yangtze Inst Conservat & Dev, Nanjing 210098, Peoples R China
关键词
water-gas two-phase flow; water-gas mass transfer; gas loss; air cushion surge chamber;
D O I
10.3390/w15152784
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water-air interaction (mixing of gas and water and gas dissolution into water) is one of the main reasons for gas loss in air cushion surge chambers. With the increase of water head in hydraulic power generation systems, the heat and mass transfer process at the water-air interface under high-pressure conditions intensifies, and the water-air interaction is further strengthened. If some gas is mixed/dissolved in water and enters downstream pipelines, it will affect the safety of the unit. At present, there has been no theoretical or systematic research on gas loss and related water gas two-phase flow in air cushion surge chambers under high-pressure conditions. Therefore, this article established an air loss model for an air cushion surge chamber based on the VOF model and gas-liquid mass transfer theory. We analyzed the mechanism of gas loss in the gas chamber through simulation and quantitatively expressed the gas loss. The results indicate that during a typical large fluctuation process, the gas-liquid mass transfer process at the water-air interface, air mass, and vortex is very strong, with a pressure chamber of approximately 923.89 m(3). The gas dissolved in water enters the water diversion system, with a length of 28.75 m(3). High pressure gas enters the water diversion system in the form of air masses. When considering the water inlet on the right side of the air chamber, the total gas loss in the air chamber is slightly lower (854.18 m(3)) and no mixed air mass was detected entering the connecting pipe.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Vertical dynamics of high-pressure air cushion bearing module: Stability and auto-oscillation
    Wang, Dongyun
    Mochalin, Ievgen
    Qiu, Yibo
    E, Shiju
    Khalatov, Artem
    Cai, Jiancheng
    JOURNAL OF SOUND AND VIBRATION, 2023, 565
  • [32] Estimation of the air entrainment characteristics of a transient high-pressure diesel spray
    Choi, W
    Choi, BC
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2005, 219 (D8) : 1025 - 1036
  • [33] Study on the thermodynamic characteristics of the high-pressure gas in reciprocating mechanism
    Wang, C.
    Zhang, P. L.
    Fu, J. P.
    Zhang, X. D.
    NEW TRENDS IN FLUID MECHANICS RESEARCH: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON FLUID MECHANICS, 2007, : 498 - 498
  • [34] DIRECT MEASUREMENT OF HIGH-PRESSURE GAS DENSITY WITH AN ION-CHAMBER DENSITOMETER
    FRIAR, BW
    GLOWER, DD
    MARCO, SM
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 1975, 97 (01): : 71 - 77
  • [35] High-pressure gas quenching using a cold chamber to increase cooling capacity
    Segerberg, S
    Troell, E
    HEAT TREATMENT OF METALS, 1997, 24 (01): : 21 - 24
  • [36] DIRECT MEASUREMENT OF HIGH-PRESSURE GAS DENSITY WITH AN ION-CHAMBER DENSITOMETER
    FRIAR, BW
    GLOWER, DD
    MARCO, SM
    MECHANICAL ENGINEERING, 1975, 97 (02) : 61 - 61
  • [37] A VERSATILE CHAMBER FOR MICROPHYSIOLOGIC STUDIES WITH GAS-MIXTURES UNDER HIGH-PRESSURE
    FAGNI, L
    HUGON, M
    FOLCO, A
    IMBERT, G
    UNDERSEA BIOMEDICAL RESEARCH, 1987, 14 (02): : 161 - 168
  • [38] Fuzzy control of a two-stage high-pressure gas reduction station
    Fletcher, I
    Burn, K
    Arden, WJB
    APPLICATION OF MULTI-VARIABLE SYSTEM TECHNIQUES (AMST '98), 1998, : 231 - 242
  • [39] 3-D simulation of transient flow patterns in a corridor-shaped air-cushion surge chamber based on computational fluid dynamics
    夏林生
    程永光
    周大庆
    Journal of Hydrodynamics, 2013, 25 (02) : 249 - 257
  • [40] 3-D simulation of transient flow patterns in a corridor-shaped air-cushion surge chamber based on computational fluid dynamics
    Xia Lin-sheng
    Cheng Yong-guang
    Zhou Da-qing
    JOURNAL OF HYDRODYNAMICS, 2013, 25 (02) : 249 - 257