Comparison of random urine protein/creatinine ratio with 24-hour urine protein in suspected pre-eclampsia

被引:0
|
作者
Olayinka, Lily [1 ,2 ]
Garnett, Emily [1 ,2 ]
Burnett, Brian [3 ]
Devaraj, Sridevi [1 ,2 ,4 ,5 ]
机构
[1] Baylor Coll Med, Dept Pathol & Immunol, Houston, TX 77030 USA
[2] Texas Childrens Hosp, Dept Pathol, Div Lab Med, Sect Clin Chem, Houston, TX 77030 USA
[3] Baylor Coll Med, Dept Obstet & Gynecol, Div Maternal Fetal Med, Houston, TX 77030 USA
[4] Baylor Coll Med, Dept Pathol & Immunol, 6621 Fannin St, Houston, TX 77030 USA
[5] Texas Childrens Hosp, 6621 Fannin St, Houston, TX 77030 USA
关键词
Pre-eclampsia; Protein-creatinine-ratio; Proteinuria; 24-H urine protein excretion; TO-CREATININE RATIO; SPOT URINE; WOMEN; DIAGNOSIS;
D O I
10.1016/j.plabm.2023.e00316
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Introduction: Proteinuria is one of the classical criteria for the diagnosis of pre-eclampsia. The gold standard remains the measurement of 24-h urine protein which is time consuming and prone to preanalytical errors. Random urine protein creatinine ratio (UPCR) is endorsed by clinical practice guidelines as a faster alternative. The aim of this study was to evaluate the correlation between the 24-h urine protein excretion and UPCR in the identification of proteinuria in suspected preeclamptic patients. Method: A total of 51 women with suspected pre-eclampsia from the maternal fetal clinic of our institution were retrospectively studied. The correlation between the UPCR in random urine samples and protein excretion in the 24-h urine collection was determined by Deming Regression analysis and Pearson correlation on EP evaluator and SPSS respectively. Result: There was a significant positive correlation between the numerical values obtained by 24-h urine protein and the UPCR (R = 0.88, P < 0.001). Concordance analysis showed 81.1% positive agreement for proteinuria between methods (>300 mg/24hr and >0.3) and 71.4% negative agreement. The clinical sensitivity and specificity of the UPCR was 74% and 69% respectively.Conclusion: Overall, UPCR was well correlated with 24-h urine protein and could be an effective and compliant screening tool to indicate proteinuria in preeclamptic patients.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Correlation of random urine protein creatinine (P-C) ratio with 24-hour urine protein and P-C ratio, based on physical activity: a pilot study
    Sadjadi, Seyed-Ali
    Jaipaul, Navin
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2010, 6 : 351 - 357
  • [42] Urine Calcium-Creatinine Ratio in Prediction of Pre-eclampsia
    Tejaswi, Mannava Sai
    Mangala, Janu Kanthi
    Vinya, Paladugu
    Bhaskaran, Renjitha
    JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2023, 73 (01): : 51 - 56
  • [43] PROTEIN-CREATININE RATIO IN 24-HOUR URINE VERSUS SPOT URINE IN THE FOLLOW-UP OF PROTEINURIC CKD
    Shabaka, Amir
    Garbiras, Mariana
    Lopez de la Manzanara, Virginia
    Delgado, Jesus
    Cruz Cardenas, Maria
    Martin, Leyre
    Calvo, Marta
    Hadad, Fernando
    Ubeda, Isabel
    Antonio Herrero, Jose
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [44] A New Gender-Specific Formula to Estimate 24-Hour Urine Protein from Protein to Creatinine Ratio
    Marco Mayayo, Maria-Paz
    Alonso, Montserrat Martinez
    Valdivielso Revilla, Jose M.
    Fernandez-Giraldez, Elvira
    NEPHRON, 2016, 133 (04) : 232 - 238
  • [45] Spot Urine Protein-to-Creatinine Ratio Compared With 24-Hour Urinary Protein in Patients With Kidney Transplant
    Wahbeh, Ayman M.
    EXPERIMENTAL AND CLINICAL TRANSPLANTATION, 2014, 12 (04) : 300 - 303
  • [46] ANALYSIS OF SPOT URINE PROTEIN TO CREATININE RATIO AS AN INDICATOR OF 24-HOUR URINARY PROTEIN EXCRETION IN NEPHROTIC SYNDROME
    Zahid, Mahmood Ahmad
    Akram, Muhammad Ufeen
    Hussain, Muzzamal
    INDO AMERICAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2019, 6 (04): : 7432 - 7436
  • [47] The Concordance of 24-Hour Urine Total Protein With Protein/Creatinine Ratios in the Diagnosis of Preeclampsia
    Holbert, Michael
    Tuemler, Erin
    Namaky, Devin
    OBSTETRICS AND GYNECOLOGY, 2016, 127 : 154S - 155S
  • [48] Diagnostic accuracy of random urinary protein-to-creatinine ratio for proteinuria in patients with suspected pre-eclampsia
    Yael Pasternak
    Dror Lifshitz
    Yael Shulman
    Liran Hiersch
    Eli Rimon
    Michael Kuperminc
    Yariv Yogev
    Eran Ashwal
    Archives of Gynecology and Obstetrics, 2021, 304 : 109 - 115
  • [49] Diagnostic accuracy of random urinary protein-to-creatinine ratio for proteinuria in patients with suspected pre-eclampsia
    Pasternak, Yael
    Lifshitz, Dror
    Shulman, Yael
    Hiersch, Liran
    Rimon, Eli
    Kuperminc, Michael
    Yogev, Yariv
    Ashwal, Eran
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2021, 304 (01) : 109 - 115
  • [50] Protein:: Creatinine ratio in random urine samples is a reliable marker of increased 24-hour protein excretion in hospitalized women with hypertensive disorders of pregnancy
    Leanos-Miranda, Alfredo
    Marquez-Acosta, Janeth
    Romero-Arauz, Fernando
    Cardenas-Mondragon, Guadalupe M.
    Rivera-Leanos, Roxana
    Isordia-Salas, Irma
    Ulloa-Aguirre, Alfredo
    CLINICAL CHEMISTRY, 2007, 53 (09) : 1623 - 1628