MOBSDEA-BASED OPTIMAL SIZING AND SITING OF RENEWABLE ENERGY-BASED DISTRIBUTED GENERATION UNITS TO REDUCE: POWER LOSSES, ELECTRICAL ENERGY COST AND VOLTAGE PROFILE DEVIATION

被引:1
|
作者
Moradi, Mosayeb [1 ]
Najafi, Maryam [2 ]
Kakavand, Ali [3 ]
Falehi, Ali Darvish [4 ]
机构
[1] Islamic Azad Univ, Tehran Sci & Res Branch Damavand, Dept Elect Engn Control, Tehran, Iran
[2] Isfahan Elect Distribut Co, Esfahan, Iran
[3] Persian Gulf Bidboland Gas Refining Co, Behbahan, Iran
[4] Islamic Azad Univ, Shadegan Branch, Dept Elect Engn, Shadegan, Iran
来源
关键词
capacitor bank; distributed generation; multi-objective bezier search differential evolution algorithm; renewable energy; sizing and siting optimization scheme; OPTIMIZATION; ALGORITHM; EVOLUTION; DESIGN; SYSTEM;
D O I
10.30638/eemj.2023.165
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Optimal sizing and siting of the renewable energy distributed generation (REDG) and capacitor bank (CB) units in the distribution systems takes over several advantageous economical and practical consequences which can effectively enhance the overall performance of distribution system issues. The sizing and siting optimization scheme for REDG, specially wind turbine (WT) and photovoltaic (PV) corresponds to a tough mission because of their stochastic nature. This paper aims to propose a novel optimization scheme based on multi-objective bezier search differential evolution algorithm (MOBSDEA) to solve the accurate sizing and siting of REDG and CB units which will be followed by the economical and practical benefits. Hence, some important objective functions such as: reduction of power losses, cost-effectiveness of electrical energy and enhancement of voltage profile are considered. Two different power systems have been studied to approve the proposed optimal sizing and siting scheme. Finally, the simulations result under IEEE 33-bus and IEEE 69-bus power systems have determinedly confirmed the high-performance of MOBSDEA-based optimal sizing and siting scheme as compared to other optimization algorithms. A brief improvement of simulation results in percentage is presented as follows: (1) the power loss reduction using MOBSDEA-based optimization has been attained 88.2% and 69.8% for IEEE 33-bus and IEEE 69-bus power systems, respectively. (2) The energy production cost reduction using MOBSDEAbased optimization has been attained 19.2% and 32.8% for IEEE 33-bus and IEEE 69-bus power systems, respectively. The voltage profile deviation reduction using MOBSDEA-based optimization has been attained 5.4% and 3.1% for IEEE 33-bus and IEEE 69bus power systems, respectively.
引用
收藏
页码:1913 / 1924
页数:12
相关论文
共 50 条