Seismic performance assessment and retrofitting proposal for a historic masonry school building (Bursa, Turkiye)

被引:8
|
作者
Cosgun, Turgay [1 ]
Ceylan, Oguz [2 ]
Nasery, Mohammad Manzoor [3 ]
Guler, Omer [4 ]
Sayin, Baris [1 ]
Uzdil, Oguz [5 ]
Akcay, Cemil [6 ]
机构
[1] Istanbul Univ Cerrahpasa, Dept Civil Engn, TR-34320 Istanbul, Turkiye
[2] Mimar Sinan Fine Arts Univ, Dept Architecture, TR-34427 Istanbul, Turkiye
[3] Dynam Muhendislik Co, TR-61010 Trabzon, Turkiye
[4] Restorasyon Co, ARJ Mimarlik, TR-16220 Bursa, Turkiye
[5] Istanbul Univ Cerrahpasa, Inst Grad Studies, TR-34320 Istanbul, Turkiye
[6] Istanbul Univ, Dept Architecture, TR-34116 Istanbul, Turkiye
关键词
Architectural heritage; Masonry building; Retrofitting proposal; Timber slab; Seismic performance analysis; HERITAGE; BEHAVIOR;
D O I
10.1016/j.cscm.2023.e02087
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The current paper presents all stages of a masonry building restoration including seismic per-formance assessment of the restored building, and a seismic retrofitting proposal accordingly. All these practices were carried out on a historical school building with timber slabs constructed in 1912. The study was composed of six stages: i. Historical research to identify all previous in-terventions in the building, ii. On-site examinations to determine the geometrical and structural properties of the building, iii. Laboratory tests to identify original material properties and determine repair materials, iv. Restoration decision and implementation of the restoration, v. Numerical analyses to assess the seismic performance of the restored building, and vi. Retrofitting proposal. The primary aim of this study is to present a comprehensive guide for seismic perfor-mance assessment and retrofitting approaches for similar buildings. The story shear forces and inter-story drifts of the examined building were obtained by linear and nonlinear analyses and compared with the limit values given in the applicable seismic code; accordingly, the seismic performance of the building was assessed. On the other hand, vertical and lateral bending collapse mechanisms were determined by local analyses. Based on the obtained findings, the building was found to have sufficient displacement capacity; however, failed in shear. Addi-tionally, we believe that the presented restoration practices and seismic performance assessment aiming the structural integrity of the historic building will contribute to the literature.
引用
收藏
页数:35
相关论文
共 50 条
  • [11] Comparison of seismic models for a historic masonry building
    Saba, Manuel
    Meloni, Daniel
    [J]. UIS INGENIERIAS, 2018, 17 (02): : 105 - 114
  • [12] Seismic analysis and retrofit of a historic masonry building
    Spyrakos, CC
    Touliatos, P
    Patsilivas, D
    Pelekis, G
    Xampesis, A
    Maniatakis, CA
    [J]. EARTHQUAKE RESISTANT ENGINEERING STRUCTURES V, 2005, 81 : 523 - 531
  • [13] Seismic Assessment and Retrofitting of an Historical Masonry Building Damaged during the 2016 Centro Italia Seismic Event
    Zucca, Marco
    Reccia, Emanuele
    Longarini, Nicola
    Cazzani, Antonio
    [J]. APPLIED SCIENCES-BASEL, 2022, 12 (22):
  • [14] Analysis and seismic retrofitting of unreinforced masonry building: a case study
    Aziz I.
    Ahsan R.
    Sakib M.S.
    Aziz S.
    Islam M.A.
    Ansary M.A.
    [J]. Asian Journal of Civil Engineering, 2021, 22 (3) : 443 - 460
  • [15] Seismic Base Isolation of a Strategic Historic Masonry Building
    Zordan, Tobia
    Romano, Alessandra
    Parisi, Fulvio
    [J]. SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 524 - 531
  • [16] SEISMIC REHABILITATION OF A HISTORIC BUILDING WITH MASONRY - WOODEN STRUCTURE
    Lute, Marina
    [J]. NANO, BIO AND GREEN - TECHNOLOGIES FOR A SUSTAINABLE FUTURE, VOL II (SGEM 2015), 2015, : 569 - 574
  • [17] Simplified and refined methods for seismic vulnerability assessment and retrofitting of an Italian cultural heritage masonry building
    Formisano, A.
    Marzo, A.
    [J]. COMPUTERS & STRUCTURES, 2017, 180 : 13 - 26
  • [18] Seismic Retrofitting for Chord Reinforcement for Unreinforced Masonry Historic Buildings with Flexible Diaphragms
    Hsiao, J. Kent
    Tezcan, Jale
    [J]. PRACTICE PERIODICAL ON STRUCTURAL DESIGN AND CONSTRUCTION, 2012, 17 (03) : 102 - 109
  • [19] Seismic risk assessment of Tehran masonry school buildings and prioritizing them for seismic retrofitting using reliability methods
    Alimohammadi, Hassan
    Bakhshi, Ali
    Yekrangnia, Mohammad
    [J]. NATURAL HAZARDS, 2024,
  • [20] Numerical assessment of accumulated seismic damage in a historic masonry building. A case study
    Sandoval, Cristian
    Valledor, Roberto
    Lopez-Garcia, Diego
    [J]. INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2017, 11 (08) : 1177 - 1194