Partial Discharge Ultrasonic Detection Based on Sagnac Optical Interference Technique

被引:1
|
作者
Jiang, Jun [1 ]
He, Yaqian [1 ]
Song, Yu [2 ]
Wang, Ruizhi [1 ]
Li, Xiaohan [3 ]
Ma, Guoming [4 ,5 ]
Wu, Qiang [6 ,7 ]
Liu, Jun [8 ]
机构
[1] Nanjing Univ Aeronaut & Astronaut, Jiangsu Key Lab New Energy Generat & Power Conver, Nanjing 211106, Jiangsu, Peoples R China
[2] State Grid Huzhou Power Supply Co, Hangzhou 313000, Peoples R China
[3] State Grid Jiangsu Elect Power Co Ltd, Res Inst, Nanjing 211103, Peoples R China
[4] North China Elect Power Univ, State Key Lab Alternate Elect Power Syst Renewabl, Beijing 102206, Peoples R China
[5] North China Elect Power Univ, Beijing Key Lab High Voltage & EMC, Beijing 102206, Peoples R China
[6] Northumbria Univ, Fac Engn & Environm, Newcastle Upon Tyne NE1 8ST, Tyne & Wear, England
[7] Nanchang Hangkong Univ, Key Lab Nondestruct Test, Minist Educ, Nanchang 330063, Jiangxi, Peoples R China
[8] Hangzhou Qianjiang Elect Grp Co Ltd, Hangzhou 311243, Peoples R China
基金
中国博士后科学基金;
关键词
Interference; optical fiber sensor (OFS); partial discharge (PD); polarization state; sensitivity; FIBER SENSOR; LOCALIZATION;
D O I
10.1109/JSEN.2023.3321934
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Partial discharge (PD) ultrasonic detection based on optical interference technique shows practical advantages such as anti-electromagnetic interference, intrinsic safety, and implantability of power equipment, but sensitivity improvement is still a necessity. In this article, the sensitivity is improved by polarization state control and interference structure parameter adjustment. For the disorder of polarization state in the interference system, the detection sensitivity within 20-300 kHz can be improved by 6.48 dB with the help of polarization control. In order to meet the PD detection requirements for various power apparatus, an optical PD detection method based on Sagnac interference structure is proposed. The frequency response can be dynamically adjusted according to the type of PD signals. For the typical PD model in the air, the frequency response of the sensor can be controlled at 20-100 kHz by using a 2000 m delay fiber, and the detection amplitude of the sensor is 5.85 times than that of the conventional piezoelectric transducer (PZT) sensor. For the detection of PD signals in insulating oil, the frequency response can be moved to 20-160 kHz by using a delay fiber with length of 500 m, and the detection amplitude of the sensor is 12.68 times than that of PZT sensor. Therefore, the proposed PD sensor based on the Sagnac interference shows the advantages of adjustable frequency response, multiscenario application, and high detection sensitivity.
引用
收藏
页码:27382 / 27389
页数:8
相关论文
共 50 条
  • [1] Partial Discharge Detection Based on Optimization of Optical Probe and Sagnac Interference
    Song, Yu
    Jiang, Jun
    He, Yaqian
    Zhou, Hongyang
    Ma, Guoming
    Li, Xiaohan
    Zhang, Dongdong
    Wang, Shuzheng
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [2] Characteristics of the propagation of partial discharge ultrasonic signals on a transformer wall based on Sagnac interference
    江军
    王凯
    吴雪瑞
    马国明
    张潮海
    [J]. Plasma Science and Technology, 2020, (02) : 12 - 20
  • [3] Characteristics of the propagation of partial discharge ultrasonic signals on a transformer wall based on Sagnac interference
    Jiang, Jun
    Wang, Kai
    Wu, Xuerui
    Ma, Guoming
    Zhang, Chaohai
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2020, 22 (02):
  • [4] Partial Discharge Detection and Sensitivity Improvement for Bushing Based on Optical Interference Technique
    Jiang, Jun
    Song, Yu
    Wang, Kai
    Lu, Yuncai
    Li, Jiansheng
    Ranjan, Prem
    Zhang, Chaohai
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (04) : 2797 - 2804
  • [5] The Anti-Interference Method of Michelson Optical Fiber Interferometer for GIS Partial Discharge Ultrasonic Detection
    Zhou, Hong-yang
    Zhang, Meng
    Ma, Guo-ming
    Li, Cheng-rong
    Cui, Bo-yuan
    Yin, Yu
    Wu, Yu-yi
    [J]. 2019 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2019, : 283 - 286
  • [6] Optical Ultrasonic Detection for Partial Discharge Under Pulsed High Voltage
    Jiang, Jun
    He, Yaqian
    Song, Yu
    Wu, Qiang
    Wang, Qian
    [J]. IEEE Transactions on Instrumentation and Measurement, 2024, 73
  • [7] Partial Discharge Ultrasound Detection Using the Sagnac Interferometer System
    Wang, Yu
    Li, Xiaomin
    Gao, Yan
    Zhang, Hongjuan
    Wang, Dong
    Jin, Baoquan
    [J]. SENSORS, 2018, 18 (05)
  • [8] An extrinsic Fabry-Perot interference fiber sensor for ultrasonic detection of partial discharge
    Zhang, X. I. M. I. N.
    Qian, S. E. N.
    Liu, H. U. I. X. I. N.
    Chen, C. H. U. A. N.
    Deng, C. H. U. A. N. L. U.
    Hu, C. H. E. N. G. Y. O. N. G.
    Huang, Y., I
    [J]. OPTICA APPLICATA, 2023, 53 (02) : 199 - 211
  • [9] Partial Discharge Detection in Transformer Based on Optical Method
    Xie, Rui
    Ge, Xinyuan
    Sun, Zheng
    Wang, Haoyi
    Zhang, Yin
    Zhang, GuoZhi
    Zhang, XiaoXing
    [J]. 2018 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2018, : 3243 - 3248
  • [10] Detection technology of partial discharge in transformer based on optical signal
    Jia, Shuangrui
    Jia, Yunfei
    Bu, Zewei
    Li, Simeng
    Lv, Liang
    Ji, Shengchang
    [J]. ENERGY REPORTS, 2023, 9 : 98 - 106