Changes in continuous glucose monitoring metrics and predictors of improvement 12 months after conversion from Freestyle Libre to Freestyle Libre 2

被引:4
|
作者
Stimson, Roland H. [1 ,2 ]
Dover, Anna R. [1 ]
Strachan, Mark W. J. [3 ]
Wright, Rohana J. [4 ]
Forbes, Shareen [1 ,2 ]
Gibb, Fraser W. [1 ,2 ,5 ]
机构
[1] Royal Infirm Edinburgh NHS Trust, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Scotland
[2] Univ Edinburgh, Univ BHF Ctr Cardiovasc Sci, Edinburgh, Scotland
[3] Western Gen Hosp, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Scotland
[4] St Johns Hosp, Edinburgh Ctr Endocrinol & Diabet, Edinburgh, Scotland
[5] Royal Infirm Edinburgh NHS Trust, Edinburgh Ctr Endocrinol & Diabet, Little France Crescent, Edinburgh EH16 4SA, Scotland
关键词
continuous glucose monitoring; hypoglycaemia; sensors; time in range (TIR); type; 1; diabetes; MULTICENTER; ADULTS;
D O I
10.1111/dme.15130
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims: We sought to assess whether conversion from Freestyle Libre to Freestyle Libre 2 (with low and high glucose alert functions) was associated with improved glucose metrics.Research Design and Methods: A prospective observational study to assess changes in CGM metrics in 672 adults with type 1 diabetes when converting to Freestyle Libre 2. Secondary outcomes included predictors of reduction in time below range (TBR) and increase in time in range (TIR).Results: TBR fell by a median of 1.0% (IQR -2.7 to 0.3, p < 0.001) after 12 months and TIR decreased by 1.0% (-8.7 to 6.0, p = 0.004). TIR did not fall in people using high glucose alerts (p = 0.353). Average duration of low glucose events (<3.9 mmoL/L) fell by 10 min (-46 to 18, p < 0.001). Significant improvements in TIR (p = 0.029) and time above 13.9 mM (p = 0.002) were observed in those using high glucose alerts. Alert threshold settings were not associated with glycaemic response; however, low alert use was independently associated with a fall in TBR of =0.5% (HR 1.9 [95% CI 1.2-3.1], p = 0.009) and high alert use was independently associated with a rise in TIR of =5% (HR 1.6 [95% CI 1.0-2.5], p = 0.043) at 12 months.ConclusionsConversion to Freestyle Libre 2 was associated with significant improvements in low glucose metrics. Alert function users were more likely to see improvements across all CGM metrics. Challenges remain in encouraging alert use, helping users set optimal alert thresholds and optimizing response to alerts.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Analytical Performance of the FreeStyle Libre 2 Glucose Sensor in Healthy Male Adults
    Fellinger, Eva
    Brandt, Tom
    Creutzburg, Justin
    Rommerskirchen, Tessa
    Schmidt, Annette
    SENSORS, 2024, 24 (17)
  • [23] Performance of the FreeStyle Libre Flash glucose monitoring system in patients with type 1 and 2 diabetes mellitus
    Fokkert, M. J.
    van Dijk, P. R.
    Edens, M. A.
    Abbes, S.
    de Jong, D.
    Slingerland, R. J.
    Bilo, H. J. G.
    BMJ OPEN DIABETES RESEARCH & CARE, 2017, 5 (01):
  • [24] Contact dermatitis from MiaoMiao (an add-on transmitter to FreeStyle Libre flash glucose monitoring system)
    Gatica-Ortega, Maria-Elena
    Pastor-Nieto, Maria-Antonia
    Torres-Aranda, Rafaela
    Luna-Bastante, Loreto
    Perez-Hortet, Cristina
    CONTACT DERMATITIS, 2021, 85 (01) : 92 - 94
  • [25] Comparison of glucose monitoring between Freestyle Libre Pro and iPro2 in patients with diabetes mellitus
    Kumagai, Ryo
    Muramatsu, Aiko
    Fujii, Masanao
    Katakura, Yukino
    Ito, Kei
    Fujie, Keiko
    Nakata, Yoshio
    Hashimoto, Koichi
    Yagyu, Hiroaki
    JOURNAL OF DIABETES INVESTIGATION, 2019, 10 (03) : 851 - 856
  • [26] Benefits of using the Freestyle Libre flash glucose monitoring system for patients with type 1 diabetes
    Jones, A. M.
    DIABETIC MEDICINE, 2020, 37 : 64 - 65
  • [27] Evaluation of the FreeStyle® Libre Flash Glucose Monitoring System in Children and Adolescents with Type 1 Diabetes
    Massa, Guy G.
    Gys, Inge
    Op't Eyndt, Anniek
    Bevilacqua, Esmiralda
    Wijnands, Anne
    Declercq, Peter
    Zeevaert, Renate
    HORMONE RESEARCH IN PAEDIATRICS, 2018, 89 (03): : 189 - 199
  • [28] Accuracy of FreeStyle Libre flash glucose monitoring in patients with type 2 diabetes who migrated from highlands to plains
    Sun, Zeng-Mei
    Du, Yuan-Ze
    Wang, Su-Yuan
    Sun, Shu-Yao
    Ye, Yan
    Sun, Xue-Ping
    Li, Ming-Xia
    He, Hua
    Long, Wun-Chun
    Zhang, Cheng-Hui
    Yao, Xuan-Yu
    Fan, Wu-Yi
    Wang, Ling
    Wu, Yun-Hong
    WORLD JOURNAL OF DIABETES, 2024, 15 (06)
  • [29] Assessment of the FreeStyle Libre 2 interstitial glucose monitor in hypo- and euglycemic cats
    Berg, Alisa S.
    Crews, Chiquitha D.
    Adin, Christopher
    Alfonso-Castro, Adriana
    Hill, Susan B.
    Mott, Jocelyn
    Gilor, Chen
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2023, 37 (05) : 1703 - 1709
  • [30] Flash Continuous Glucose Monitoring (FreeStyle Libre 14-Day System) for Self-Management of Diabetes Mellitus
    Choi, Hiu Ying Joanna
    AMERICAN FAMILY PHYSICIAN, 2021, 103 (11) : 688 - 690