Air-Permeable Building Envelopes for Building Ventilation and Heat Recovery: Research Progress and Future Perspectives

被引:3
|
作者
Zhang, Chong [1 ,2 ]
Yu, Zhanzhi [3 ]
Zhu, Qiuyuan [4 ]
Shi, Hongqi [4 ]
Yu, Zhongyi [5 ]
Xu, Xinhua [3 ]
机构
[1] Huazhong Univ Sci & Technol, Sch Architecture & Urban Planning, Wuhan 430074, Peoples R China
[2] Hubei Engn & Technol Res Ctr Urbanizat, Wuhan 430074, Peoples R China
[3] Huazhong Univ Sci & Technol, Dept Bldg Environm & Energy Engn, Wuhan 430074, Peoples R China
[4] Wuhan Second Ship Design & Res Inst, Wuhan 430064, Peoples R China
[5] CITIC Gen Inst Architectural Design & Res Co Ltd, Wuhan 430071, Peoples R China
基金
中国国家自然科学基金;
关键词
air-permeable building envelope; dynamic insulation; building ventilation; heat recovery; porous material; healthy building; STEADY-STATE BEHAVIOR; DOUBLE-SKIN FACADES; DYNAMIC INSULATION; THERMAL PERFORMANCE; ENERGY PERFORMANCE; POROUS MATERIALS; BREATHING WALLS; EXHAUST; INFILTRATION; DESIGN;
D O I
10.3390/buildings14010042
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Air-permeable building envelopes (APBEs) utilize the infiltrated or exfiltrated airflow within porous materials to directly change their temperature distribution to reduce heat loss/gain. APBEs effectively integrate building ventilation and heat recovery to achieve excellent thermal insulation while improving indoor air quality. This paper presents a comprehensive review of the fundamentals and classifications, historical evolution over time, opportunities and benefits, and future views on APBEs. It can be treated as a responsive building envelope that enables building envelopes to dynamically change the U-values by varying the infiltrated or exfiltrated airflow rate within a porous material. Previous studies have indicated that the U-value of 0.1 W/(m2 center dot K) can be realized by employing APBEs. Moreover, some research demonstrates that APBEs could act as high-performance air filters that reduce over 90% of particulate matter within fresh, ventilated air. Some factors, such as airflow rate, thickness, and thermal conductivity of porous materials, have a significant influence on the effectiveness of APBEs. For practical applications, integrating the APBE with passive building ventilation can help reduce the initial cost and facilitate decarbonization in buildings. Moreover, advanced control strategies could collaboratively optimize the operation of ABPEs and build energy systems to maximize their energy-saving potential.
引用
收藏
页数:23
相关论文
共 50 条
  • [21] Analysis of heat gain decrease achieved by ventilation heat recovery in solar cooling building: case study
    Gil, Bartosz
    Rosiek, Sabina
    Kasperski, Jacek
    Nems, Magdalena
    Nems, Artur
    Batlles, Francisco J.
    PROCEEDINGS OF THE ISES SOLAR WORLD CONFERENCE 2019 AND THE IEA SHC SOLAR HEATING AND COOLING CONFERENCE FOR BUILDINGS AND INDUSTRY 2019, 2019, : 2521 - 2528
  • [22] Experimental assessment of a PCM to air heat exchanger storage system for building ventilation application
    Labat, M.
    Virgone, J.
    David, D.
    Kuznik, F.
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 375 - 382
  • [23] Unveiling the synergy of passive cooling, efficient ventilation, and indoor air quality through optimal PCM location in building envelopes
    Khayyaminejad, Amirhossein
    Fartaj, Amir
    JOURNAL OF ENERGY STORAGE, 2024, 89
  • [24] Performance of a heat recovery ventilation system for controlling human exposure to airborne particles in a residential building
    Park, Seongjun
    Lee, Shinhye
    Yeo, Myoung-Souk
    Rim, Donghyun
    BUILDING AND ENVIRONMENT, 2023, 239
  • [25] Continuous automated ventilation heat recovery efficiency performance assessment using building monitoring system
    Kull, Tuule Mall
    Mikola, Alo
    Tukia, Andres
    Kose, Ahmet
    Petlenkov, Eduard
    Thalfeldt, Martin
    COLD CLIMATE HVAC & ENERGY 2021, 2021, 246
  • [26] A review of heat recovery technologies and their frost control for residential building ventilation in cold climate regions
    Bai, H. Y.
    Liu, P.
    Alonso, M. Justo
    Mathisen, H. M.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 162
  • [27] Modeling the heat, air, and moisture response of building envelopes: What material properties are needed, how trustful are the predictions?
    K. U. Leuven, Department of Civil Engineering, Laboratory of Building Physics, Kasteelpark Arenberg 40, B-3001 Leuven, Belgium
    J. ASTM Int., 2007, 2
  • [28] Energy efficiency of exhaust air heat recovery while controlling building air humidity: A case study
    Zevenhoven, Ron
    Erlund, Rickard
    Tveit, Tor-Martin
    ENERGY CONVERSION AND MANAGEMENT, 2019, 195 : 1238 - 1243
  • [29] Modeling the heat, air, and moisture response of building envelopes: What material properties are needed, how trustful are the predictions?
    Hens, Hugo S. L. C.
    HEAT-AIR-MOISTURE TRANSPORT: MEASUREMENTS ON BUILDING MATERIALS, 2007, 1495 : 1 - 11
  • [30] Experimental investigation of heat recovery system for building air conditioning in hot and humid areas
    Delfani, Shahram
    Pasdarshahri, Hadi
    Karami, Maryam