Is new always better: comparison of the femoral neck system and the dynamic hip screw in the treatment of femoral neck fractures

被引:13
|
作者
Schuetze, Konrad [1 ]
Burkhardt, Jakob [1 ]
Pankratz, Carlos [1 ]
Eickhoff, Alexander [1 ]
Boehringer, Alexander [1 ]
Degenhart, Christina [1 ]
Gebhard, Florian [1 ]
Cintean, Raffael [1 ]
机构
[1] Ulm Univ, Dept Trauma Hand & Reconstruct Surg, Albert Einstein Allee 23, D-89081 Ulm, Germany
关键词
Hip fracture; Cut out; Complications; TIP-APEX DISTANCE; FIXATION; PREDICTORS; FAILURE;
D O I
10.1007/s00402-022-04551-w
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Hip fractures in the elderly population are common and the number of patients is rising. For young and geriatric patients with undisplaced fractures osteosynthesis is the primary type of treatment. The dynamic hip screw (DHS) is around for many years and proved its value especially in displaced fractures. Since 2018 the femoral neck system (FNS) is available as an alternative showing promising biomechanical results. The aim of this study is to evaluate clinical results of the FNS and compare it to the DHS. Materials and methods Patients older than 18 years with Garden I-IV fractures that were treated with osteosynthesis in a level 1 trauma center were included in the study. Between January 2015 and March 2021, all patients treated with FNS (1-hole plate, DePuy-Synthes, Zuchwil, Switzerland) or DHS (2-hole plate, DePuy-Synthes, Zuchwil, Switzerland) for proximal femur fractures were included in the study. Closed reduction was achieved using a traction table. All operations were carried out by experienced orthopedic trauma surgeons. Primary outcome measures were rate of implant failure (cut out) and surgical complications (hematoma, infection). Secondary outcome measures were Hb-difference, length of hospital stay and mortality. Results Overall, 221 patients were included in the study. 113 were treated with FNS, 108 with DHS. Mean age was 69 +/- 14 years. There were 17.2% Garden I, 47.5% Garden II, 26.7% Garden III and 8.6% Garden IV fractures. No difference between the groups for age, body mass index (BMI), Charlson comorbidity index (CCI), time to surgery, Pauwels and Garden classification, rate of optimal blade position or tip apex distance was found. FNS showed lower pre- to postoperative Hb-difference (1.4 +/- 1.1 g/l vs. 2.1 +/- 1.4 g/l; p < 0.05), shorter operating time (36.3 +/- 11.6 min vs. 54.7 +/- 17.4 min; p < 0.05) and hospital stay (8.8 +/- 4.3 d vs. 11.2 +/- 6.8 d; p < 0.05). Surgical complications (FNS 13.3% vs. DHS 18.4%, p > 0.05), rate of cut out (FNS 12.4% vs. DHS 10.2%, p > 0.05) and mortality (FNS 3.5%; DHS 0.9%; p > 0.05) showed no difference between the groups. Logistic regression showed that poor blade position was the only significant predictor for cut out and increased the risk by factor 7. Implant related infection (n = 3) and hematoma/seroma (n = 6) that needed revision was only seen in DHS group. Conclusion FNS proved to be as reliable as DHS in all patients with hip fractures. Not the type of implant but blade positioning is still key to prevent implant failure. Still due to minimal invasive approach implant related infections and postoperative hematomas might have been prevented using the FNS.
引用
收藏
页码:3155 / 3161
页数:7
相关论文
共 50 条
  • [41] Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study
    Yunfeng Tang
    Zhen Zhang
    Limin Wang
    Wei Xiong
    Qian Fang
    Guanglin Wang
    [J]. Journal of Orthopaedic Surgery and Research, 16
  • [42] Mechanical analysis of modified femoral neck system in the treatment of osteoporotic femoral neck fractures
    Nan, Chong
    Liu, Yuxiu
    Zhang, Di
    Qin, Yazhuo
    Yu, Hetong
    Liu, Yong
    Ma, Zhanbei
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [43] Effect of dynamic hip system blade on the treatment of femoral neck fractures in elderly patients with osteoporosis
    Zhao Wenbo
    Liu Lei
    [J]. 中华创伤杂志(英文版), 2014, 17 (05) : 275 - 278
  • [44] Effect of dynamic hip system blade on the treatment of femoral neck fractures in elderly patients with osteoporosis
    Zhao Wenbo
    Liu Lei
    [J]. CHINESE JOURNAL OF TRAUMATOLOGY, 2014, 17 (05) : 275 - 278
  • [45] TREATMENT OF FEMORAL-NECK FRACTURES WITH THE SLIDING COMPRESSION SCREW
    RAU, FD
    MANOLI, A
    MORAWA, LG
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (163) : 137 - 140
  • [46] Treatment of femoral neck fractures
    Bonnaire, F.
    Lein, T.
    Engler, K. -J.
    [J]. CHIRURG, 2008, 79 (06): : 595 - 611
  • [47] A new configuration of cannulated screw fixation in the treatment of vertical femoral neck fractures
    Zhang, Baokun
    Liu, Jingwen
    Zhu, Yi
    Zhang, Wei
    [J]. INTERNATIONAL ORTHOPAEDICS, 2018, 42 (08) : 1949 - 1955
  • [48] TREATMENT OF INTRACAPSULAR FRACTURES OF THE FEMORAL NECK WITH THE CHARNLEY COMPRESSION SCREW
    HARGADON, EJ
    PEARSON, JR
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1963, 45 (02): : 305 - 311
  • [49] OSTEOSYNTHESIS OF FEMORAL NECK FRACTURES: DYNAMIC HIP SCREW (DHS) OR MINI-INVASIVE TARGON FN SYSTEM?
    Dulaev, A. K.
    Tsed, A. N.
    Dzhusoev, I. G.
    Usubaliev, K. N.
    [J]. TRAVMATOLOGIYA I ORTOPEDIYA ROSSII, 2015, (03): : 12 - 21
  • [50] Treatment of femoral neck fractures
    Magnus, G